Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081262

RESUMO

We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion-photon couplings above 10-13 Ge V-1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7-4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

2.
Rev Sci Instrum ; 92(12): 124502, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972408

RESUMO

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66-3.1 µeV mass range with Dine-Fischler-Srednicki-Zhitnisky sensitivity [Du et al., Phys. Rev. Lett. 120, 151301 (2018) and Braine et al., Phys. Rev. Lett. 124, 101303 (2020)]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

3.
Phys Rev Lett ; 127(26): 261803, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35029490

RESUMO

We report the results from a haloscope search for axion dark matter in the 3.3-4.2 µeV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the Kim-Shifman-Vainshtein-Zakharov model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

4.
Phys Rev Lett ; 124(24): 241101, 2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32639799

RESUMO

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub- 2×10^{-7} eV (50 MHz) range, a tunable lumped-element LC circuit has been proposed. For the first time, through ADMX SLIC (Superconducting LC Circuit Investigating Cold Axions), a resonant LC circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting LC circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency ranges 1.7498-1.7519×10^{-7} eV (42.31-42.36 MHz), 1.7734-1.7738×10^{-7} eV (42.88-42.89 MHz), and 1.8007-1.8015×10^{-7} eV (43.54-43.56 MHz) were covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T, respectively. Exclusion results from the search data, for coupling below 10^{-12} GeV^{-1}, are presented.

5.
Phys Rev Lett ; 124(10): 101303, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32216421

RESUMO

This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range 2.81-3.31 µeV. This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics.

6.
Phys Rev Lett ; 120(15): 151301, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29756850

RESUMO

This Letter reports the results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 µeV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at subkelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultralow-noise superconducting quantum interference device amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.

7.
Phys Rev Lett ; 121(26): 261302, 2018 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-30636160

RESUMO

The µeV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM_{010} and TM_{020} modes.

8.
Eur Rev Med Pharmacol Sci ; 21(15): 3482-3489, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28829492

RESUMO

OBJECTIVE: To evaluate the norepinephrine (NE) and placental NE transporter (NET) in women with polycystic ovary syndrome (PCOS) non-treated and treated with metformin during pregnancy. PATIENTS AND METHODS: We studied sixteen pregnant women with PCOS: 8 without metformin treatment during pregnancy (PCOS-M) and 8 treated with metformin during pregnancy (PCOS+M). Sixteen pregnant women of similar age without PCOS were included as controls (Control). At 24th and 35th weeks of pregnancy, blood samples were obtained. Placentas from full-term pregnancies were collected immediately after delivery. They were divided into two samples representative from the region near the chorionic plate (fetal side) and from the region near the basal plate (maternal side). NE plasma concentrations were measured by HPLC with electrochemical detection, and placental NET protein levels were determined by Western blot. RESULTS: At week 24 of gestation, PCOS-M had higher NE plasma levels compared to control women (p < 0.001). Moreover, NET expression was lower in the maternal side of the placenta of PCOS-M compared to controls (p < 0.05). Metformin treatment normalized NE plasma levels at week 24 of gestation and NET expression in the maternal side of the placenta. In the fetal side of the placenta, NET expression was lower in PCOS-M and PCOS+M compared to control women (p < 0.001 and < 0.01, respectively). CONCLUSIONS: Our results strongly suggest that norepinephrine homeostasis is altered in pregnant women with PCOS. Remarkably, metformin administration during pregnancy decreases circulating norepinephrine levels and increases NET expression in the maternal side of placentas from PCOS women.


Assuntos
Metformina/uso terapêutico , Proteínas da Membrana Plasmática de Transporte de Norepinefrina/metabolismo , Placenta/metabolismo , Síndrome do Ovário Policístico/tratamento farmacológico , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Gravidez , Adulto Jovem
9.
Int J Obes (Lond) ; 41(11): 1636-1645, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28676682

RESUMO

BACKGROUND/OBJECTIVE: It is not clear whether maternal obesity along with fetal gender affect sex steroid metabolism during pregnancy. Therefore, we compared sex steroid concentrations and placental expression of steroidogenic enzymes between non-obese and obese pregnant women with non-pathological pregnancies, and investigated the influence of fetal gender on these parameters. METHODS: In 35 normal weight (body mass index (BMI) 20-24.9 kg m-2) (controls) and 36 obese women (BMI 30-36 kg m-2) (obese), a fasting blood sample was obtained at first and at third trimester of gestation to measure progesterone, dehydroepiandrosterone (DHEA), DHEA sulfate, androstenedione, testosterone and estradiol by liquid chromatography-tandem mass spectrometry and estrone by radioimmunoassay. In a subset of women, placental mRNA and protein expression of steroidogenic enzymes was measured by quantitative PCR and western blot, respectively. The comparisons were primarily made between controls and obese, and then separately according to fetal gender. RESULTS: At first and third trimesters of gestation serum progesterone was lower whereas testosterone was higher in obese women (P<0.05, respectively). Upon analyzing according to fetal gender, lower progesterone levels were present in obese pregnant women with male fetuses at first trimester and with female fetuses at third trimester (P<0.05, respectively). Testosterone was higher in obese women with male fetuses compared to control women with male fetuses (P<0.05). The placental protein expression of P450scc was higher in obese women compared to controls (P<0.05). P450 aromatase was higher in obese women with female fetuses (P=0.009), whereas in obese women with male fetuses P450 aromatase was lower compared to control women (P=0.026). CONCLUSIONS: Obesity in non-pathological pregnancies alters the maternal serum progesterone and testosterone concentrations depending on fetal gender. These changes can be attributed to gender-related placental adaptations, as the expression of P450 aromatase is different in placentas from females compared to males.


Assuntos
Adaptação Fisiológica/fisiologia , Obesidade/sangue , Placenta/enzimologia , Adulto , Aromatase/sangue , Western Blotting , Índice de Massa Corporal , Desidroepiandrosterona/sangue , Estradiol/sangue , Feminino , Desenvolvimento Fetal , Feto , Humanos , Recém-Nascido , Masculino , Obesidade/complicações , Obesidade/fisiopatologia , Gravidez , Progesterona/sangue , Fatores Sexuais , Testosterona/sangue , Adulto Jovem
10.
Rev. chil. endocrinol. diabetes ; 10(1): 20-23, ene. 2017. ilus
Artigo em Espanhol | LILACS | ID: biblio-869719

RESUMO

Takotsubo cardiomyopathy (MTT) is an acute ventricular dysfunction and reversible in absence of coronary disease. It is a rare presentation of pheochromocytoma and paraganglioma (FPGL). It was described for the first time in 1990 by Sato et al, the physiopathology is not clear yet. It is associated with high levels of catecholamines, vasospasm in the micro vascularization, rupture of atheromatous plaque and myiocarditis. The clinical presentation is similar to an acute myocardial infarction because of that the FPGL must be considered in patients without obstructive coronary lesions. We present a case of a 50 years old women with history of Arterial Hypertension, active smoking and Neurofibromatosis, who is admitted to emergency room with an acute myocardial pain.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cardiomiopatia de Takotsubo/etiologia , Feocromocitoma/complicações , Feocromocitoma/diagnóstico , Neoplasias das Glândulas Suprarrenais/complicações , Neoplasias das Glândulas Suprarrenais/diagnóstico , Cardiomiopatia de Takotsubo/diagnóstico , Catecolaminas/análise , Feocromocitoma/cirurgia , Neoplasias das Glândulas Suprarrenais/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...