Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Radiology ; 266(2): 433-42, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23264349

RESUMO

PURPOSE: To assess initial breast tumor hemoglobin (Hb) content before the initiation of neoadjuvant chemotherapy, monitor the Hb changes at the end of each treatment cycle, and correlate these findings with tumor pathologic response. MATERIALS AND METHODS: The HIPAA-compliant study protocol was approved by the institutional review boards of both institutions. Written informed consent was obtained from all patients. Patients who were eligible for neoadjuvant chemotherapy were recruited between December 2007 and May 2011, and their tumor Hb content was assessed by using a near-infrared imager coupled with an ultrasonography (US) system. Thirty-two women (mean age, 48 years; range, 32-82 years) were imaged before treatment, at the end of every treatment cycle, and before definitive surgery. The patients were graded in terms of their final pathologic response on the basis of the Miller-Payne system as nonresponders and partial responders (grades 1-3) and near-complete and complete responders (grades 4 and 5). Tumor vascularity was assessed from total Hb (tHb), oxygenated Hb (oxyHb), and deoxygenated Hb (deoxyHb) concentrations. Tumor vascularity changes during treatment were assessed from percentage tHb normalized to the pretreatment level. A two-sample two-sided t test was used to calculate the P value and to evaluate statistical significance between groups. Bonferroni-Holm correction was applied to obtain the corrected P value for multiple comparisons. RESULTS: There were 20 Miller-Payne grade 1-3 tumors and 14 grade 4 or 5 tumors. Mean maximum pretreatment tHb, oxyHb, and deoxyHb levels were significantly higher in grade 4 and 5 tumors than in grade 1-3 tumors (P = .005, P = .008, and P = .017, respectively). The mean percentage tHb changes were significantly higher in grade 4 or 5 tumors than in grade 1-3 tumors at the end of treatment cycles 1-3 (P = .009 and corrected P = .009, P = .002 and corrected P = .004, and P < .001 and corrected P < .001, respectively). DISCUSSION: These findings indicate that initial tumor Hb content is a strong predictor of final pathologic response. Additionally, the tHb changes during early treatment cycles can further predict final pathologic response.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/patologia , Espectroscopia de Luz Próxima ao Infravermelho , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Anticorpos Monoclonais Humanizados/administração & dosagem , Bevacizumab , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Capecitabina , Carboplatina/administração & dosagem , Ciclofosfamida/administração & dosagem , Desoxicitidina/administração & dosagem , Desoxicitidina/análogos & derivados , Doxorrubicina/administração & dosagem , Feminino , Fluoruracila/administração & dosagem , Fluoruracila/análogos & derivados , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Terapia Neoadjuvante , Gradação de Tumores , Neovascularização Patológica/diagnóstico por imagem , Paclitaxel/administração & dosagem , Curva ROC , Trastuzumab , Resultado do Tratamento
2.
Radiology ; 256(2): 367-78, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20571122

RESUMO

PURPOSE: To investigate the potential role of optical tomography in the near-infrared (NIR) spectrum with ultrasonographic (US) localization as a means of differentiating early-stage cancers from benign lesions of the breast. MATERIALS AND METHODS: The protocol was approved by the institutional review boards and was HIPAA compliant; all participants signed an informed consent. One hundred seventy-eight consecutive women (mean age, 52 years; range, 21-89 years) who underwent US-guided biopsy were imaged with a hand-held probe consisting of a coregistered US transducer and an NIR imager. The lesion location provided by coregistered US was used to guide optical imaging. Light absorption was measured at two optical wavelengths. From this measurement, tumor angiogenesis was assessed on the basis of calculated total hemoglobin concentration (tHb) and was correlated with core biopsy results. For patients diagnosed with carcinomas and followed up with subsequent excision, the tHb was correlated with pathologic parameters. RESULTS: There were two in situ carcinomas (Tis), 35 T1 carcinomas, 24 T2-T4 carcinomas, and 114 benign lesions. The mean maximum and mean average tHb of the Tis-T1 group were 102.0 micromol/L +/- 28.5 (standard deviation) and 71.9 micromol/L +/- 18.8, and those of the T2-T4 group were 100.3 micromol/L +/- 26.4 and 67.0 micromol/L +/- 18.3, respectively. The mean maximum and mean average tHb of the benign group were 55.1 micromol/L +/- 22.7 and 39.1 micromol/L +/- 14.9, respectively. Both mean maximum and mean average tHb levels were significantly higher in the malignant groups than they were in the benign group (P < .001). The sensitivity, specificity, positive predictive value, and negative predictive value for Tis-T1 cancers were 92%, 93%, 81%, and 97%. The corresponding values for T2-T4 tumors were 75%, 93%, 69%, and 95%. CONCLUSION: The angiogenesis (tHb) contrast imaged by using the NIR technique with US holds promise as an adjunct to mammography and US for distinguishing early-stage invasive breast cancers from benign lesions.


Assuntos
Neoplasias da Mama/diagnóstico , Técnica de Subtração , Tomografia Óptica/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Radiology ; 237(1): 57-66, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16183924

RESUMO

PURPOSE: To investigate prospectively the feasibility of using optical tomography with ultrasonographic (US) localization to differentiate malignant from benign breast masses and to compare optical tomography with color Doppler US. MATERIALS AND METHODS: The study was approved by the local internal review board committee and by the Human Subjects Research Review Board of Army Medical Research and Materiel Command. Signed informed consent was obtained, and the study was HIPAA compliant. Between May 2003 and March 2004, 65 consecutive women (mean age, 51 years; age range, 24-80 years) with 81 breast lesions underwent US-guided biopsy and were scanned with a combined imager. The hand-held probe, which consisted of a centrally located US transducer surrounded by near-infrared sensors, was used to simultaneously acquire coregistered US images and optical data. The lesion location obtained at US was used to guide optical imaging reconstruction. Light absorption was measured at two wavelengths. From these measurements, tumor angiogenesis was assessed on the basis of calculated total hemoglobin concentration. A Student t distribution was used to calculate the statistical significance of mean maximum and mean average hemoglobin concentrations obtained in malignant and benign lesion groups, and P < .001 was considered to indicate a statistically significant difference. RESULTS: Biopsy results revealed eight early stage invasive carcinomas (malignant group) and 73 benign lesions (benign group). The mean maximum and mean average hemoglobin concentrations in the malignant group were 122 micromol/L +/- 26.8 (+/- standard deviation) and 88 micromol/L +/- 24.5, respectively. The mean maximum and mean average hemoglobin concentrations in the benign group were 55 micromol/L +/- 24.8 and 38 micromol/L +/- 17.4, respectively. Both the maximum and average total hemoglobin concentrations were significantly higher in the malignant group compared with the benign group (P < .001). When a maximum hemoglobin concentration of 95 micromol/L was used as the threshold value, the sensitivity, specificity, positive predictive value, and negative predictive value of optical tomography were 100%, 96%, 73%, and 100%, respectively, and the sensitivity, specificity, positive predictive value, and negative predictive value of color Doppler US were 63%, 69%, 19%, and 94%, respectively. CONCLUSION: Findings indicate that optical tomography with US localization is feasible for differentiating benign and early stage malignant breast lesions.


Assuntos
Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Tomografia Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Hemoglobinas/análise , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...