Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Infect Dis ; 72(12): e1004-e1009, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33252659

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19), was first identified in Wuhan, China, in December 2019, with subsequent worldwide spread. The first US cases were identified in January 2020. METHODS: To determine if SARS-CoV-2-reactive antibodies were present in sera prior to the first identified case in the United States on 19 January 2020, residual archived samples from 7389 routine blood donations collected by the American Red Cross from 13 December 2019 to 17 January 2020 from donors resident in 9 states (California, Connecticut, Iowa, Massachusetts, Michigan, Oregon, Rhode Island, Washington, and Wisconsin) were tested at the Centers for Disease Control and Prevention for anti-SARS-CoV-2 antibodies. Specimens reactive by pan-immunoglobulin (pan-Ig) enzyme-linked immunosorbent assay (ELISA) against the full spike protein were tested by IgG and IgM ELISAs, microneutralization test, Ortho total Ig S1 ELISA, and receptor-binding domain/ACE2 blocking activity assay. RESULTS: Of the 7389 samples, 106 were reactive by pan-Ig. Of these 106 specimens, 90 were available for further testing. Eighty-four of 90 had neutralizing activity, 1 had S1 binding activity, and 1 had receptor-binding domain/ACE2 blocking activity >50%, suggesting the presence of anti-SARS-CoV-2-reactive antibodies. Donations with reactivity occurred in all 9 states. CONCLUSIONS: These findings suggest that SARS-CoV-2 may have been introduced into the United States prior to 19 January 2020.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Doadores de Sangue , China , Connecticut , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G , Iowa , Massachusetts , Michigan , Oregon , Rhode Island , Glicoproteína da Espícula de Coronavírus , Washington , Wisconsin
2.
PLoS One ; 11(6): e0156987, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27257909

RESUMO

Bacillus cereus isolates have been described harboring Bacillus anthracis toxin genes, most notably B. cereus G9241, and capable of causing severe and fatal pneumonias. This report describes the characterization of a B. cereus isolate, BcFL2013, associated with a naturally occurring cutaneous lesion resembling an anthrax eschar. Similar to G9241, BcFL2013 is positive for the B. anthracis pXO1 toxin genes, has a multi-locus sequence type of 78, and a pagA sequence type of 9. Whole genome sequencing confirms the similarity to G9241. In addition to the chromosome having an average nucleotide identity of 99.98% when compared to G9241, BcFL2013 harbors three plasmids with varying homology to the G9241 plasmids (pBCXO1, pBC210 and pBFH_1). This is also the first report to include serologic testing of patient specimens associated with this type of B. cereus infection which resulted in the detection of anthrax lethal factor toxemia, a quantifiable serum antibody response to protective antigen (PA), and lethal toxin neutralization activity.


Assuntos
Antraz/metabolismo , Antraz/microbiologia , Antígenos de Bactérias/metabolismo , Bacillus cereus/metabolismo , Bacillus cereus/patogenicidade , Toxinas Bacterianas/metabolismo , Idoso , Antraz/patologia , Bacillus cereus/isolamento & purificação , Humanos , Masculino
3.
J Infect Dis ; 204(9): 1321-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21908727

RESUMO

Cutaneous anthrax outbreaks occurred in Bangladesh from August to October 2009. As part of the epidemiological response and to confirm anthrax diagnoses, serum samples were collected from suspected case patients with observed cutaneous lesions. Anthrax lethal factor (LF), anti-protective antigen (anti-PA) immunoglobulin G (IgG), and anthrax lethal toxin neutralization activity (TNA) levels were determined in acute and convalescent serum of 26 case patients with suspected cutaneous anthrax from the first and largest of these outbreaks. LF (0.005-1.264 ng/mL) was detected in acute serum from 18 of 26 individuals. Anti-PA IgG and TNA were detected in sera from the same 18 individuals and ranged from 10.0 to 679.5 µg/mL and 27 to 593 units, respectively. Seroconversion to serum anti-PA and TNA was found only in case patients with measurable toxemia. This is the first report of quantitative analysis of serum LF in cutaneous anthrax and the first to associate acute stage toxemia with subsequent antitoxin antibody responses.


Assuntos
Antraz/epidemiologia , Antraz/imunologia , Antígenos de Bactérias/imunologia , Antitoxinas/sangue , Toxinas Bacterianas/imunologia , Surtos de Doenças , Animais , Anticorpos Antibacterianos/sangue , Anticorpos Neutralizantes/sangue , Bangladesh/epidemiologia , Humanos , Imunoglobulina G/sangue , Dermatopatias Bacterianas
4.
J Clin Microbiol ; 49(6): 2210-5, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21471339

RESUMO

Swine origin 2009 H1N1 influenza virus has spread globally to cause the first influenza pandemic of the 21st century. Serological studies can improve our understanding of the extent of human infection and risk factors associated with the transmission of this pandemic virus. The "gold standard" for serodiagnosis of human influenza virus infection is the detection of seroconversion between acute- and convalescent-stage samples. However, the timing of seroepidemiological investigations often precludes the collection of truly acute-phase sera, requiring development of serological criteria for evaluating convalescent-phase sera that optimize detection of true positives and true negatives. To guide seroepidemiological investigations into the spread of the novel 2009 pandemic H1N1 virus, we characterized serum antibody responses to 2009 H1N1 virus in 87 individuals with confirmed viral infection and 227 nonexposed U.S. individuals using microneutralization (MN) and hemagglutination inhibition (HI) assays. Sensitivity and specificity were determined for each assay alone and in combination for detection of 2009 H1N1 virus-specific antibodies in convalescent-phase sera. Although the HI assay was more specific for detecting antibody to 2009 H1N1, the MN assay was more sensitive, particularly for detecting low-titer seroconversions. A combination of titers (MN ≥ 40 and HI ≥ 20) provided the highest sensitivity (90%) and specificity (96%) for individuals aged <60 years and 92% specificity for adults aged ≥ 60 years for detection of serologically confirmed 2009 H1N1 infections in U.S. populations during the first pandemic waves. These studies provide an approach to optimize timely serological investigations for future pandemics or outbreaks of novel influenza viruses among humans.


Assuntos
Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Influenza Humana/diagnóstico , Virologia/métodos , Adolescente , Adulto , Idoso , Animais , Anticorpos Antivirais/sangue , Criança , Pré-Escolar , Testes de Inibição da Hemaglutinação , Humanos , Lactente , Vírus da Influenza A Subtipo H1N1/imunologia , Pessoa de Meia-Idade , Testes de Neutralização , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Estados Unidos , Adulto Jovem
5.
J Immunol Methods ; 333(1-2): 89-106, 2008 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-18304568

RESUMO

Quantification of anthrax lethal toxin (LTx) neutralization activity (TNA) is pivotal in assessing protective antibody responses to anthrax vaccines and for evaluation of immunotherapies for anthrax. We have adapted and redesigned the TNA assay to establish a unifying, standardized, quantitative and validated technology platform for LTx neutralization in the J774A.1 murine cell line. Critical design features of this platform are 1) the application of a free-form or constrained 4 parameter logistic (4-PL) function to model neutralization responses within and between boundary limits of 100% cell survival and 95% cell lysis and 2) to exploit innovative assay curve recognition algorithms for interpretive endpoints. The assay was validated using human serum ED50 (dilution of serum effecting 50% neutralization) as the primary reportable value (RV). Intra-operator and intermediate precision, expressed as the coefficient of variation (%CV), were high at 10.5-15.5%CV and 13.5-14.5%CV respectively. TNA assay dilutional linearity was demonstrated for human sera using linear regression analysis of log(10) transformed data with slope=0.99, intercept=-0.03 and r(2)=0.985. Assay accuracy, inferred from the precision and linearity data and using a spike-recovery approach, was high with a percent error (%E) range of only 3.4-20.5%E. The lower limit of detection (LLOD) was ED50=12 and the lower limit of quantification (LLOQ) was ED50=36. The cell-based assay was robust, tolerating incubation temperatures from 35 to 39 degrees C, CO(2) concentrations from 3% to 7% and reporter substrate (MTT) concentrations of 2.5-7.5 mg/ml. Strict assay quality control parameters were met for up to 25 cell culture passages. The long term (50 month) assay stability, determined using human reference standards AVR414 and AVR801, indicated high precision, consistent accuracy and no detectable assay drift. A customized software program provided two additional assay metrics, Quantification Titer (QT) and Threshold Titer (TT), both of which demonstrate acceptable accuracy, precision and dilutional linearity. The TT was also used to establish the assay reactivity threshold (RT). The application of the assay to sera from humans, Rhesus macaques and rabbits was demonstrated separately and by aggregate dilutional linearity analysis of the ED50 (slope=0.98, intercept=0.003, r(2)=0.989). We propose this TNA assay format with a qualified standard reference serum and customized interpretive software as a unifying platform technology for determination of functional serologic responses to anthrax vaccines and for evaluation of anthrax immunotherapeutics.


Assuntos
Antraz/imunologia , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Bacillus anthracis/imunologia , Toxinas Bacterianas/imunologia , Modelos Imunológicos , Testes de Neutralização/métodos , Animais , Antraz/prevenção & controle , Vacinas contra Antraz/imunologia , Linhagem Celular , Humanos , Macaca mulatta , Camundongos , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...