Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Infect Dis ; 204(9): 1321-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21908727

RESUMO

Cutaneous anthrax outbreaks occurred in Bangladesh from August to October 2009. As part of the epidemiological response and to confirm anthrax diagnoses, serum samples were collected from suspected case patients with observed cutaneous lesions. Anthrax lethal factor (LF), anti-protective antigen (anti-PA) immunoglobulin G (IgG), and anthrax lethal toxin neutralization activity (TNA) levels were determined in acute and convalescent serum of 26 case patients with suspected cutaneous anthrax from the first and largest of these outbreaks. LF (0.005-1.264 ng/mL) was detected in acute serum from 18 of 26 individuals. Anti-PA IgG and TNA were detected in sera from the same 18 individuals and ranged from 10.0 to 679.5 µg/mL and 27 to 593 units, respectively. Seroconversion to serum anti-PA and TNA was found only in case patients with measurable toxemia. This is the first report of quantitative analysis of serum LF in cutaneous anthrax and the first to associate acute stage toxemia with subsequent antitoxin antibody responses.


Assuntos
Antraz/epidemiologia , Antraz/imunologia , Antígenos de Bactérias/imunologia , Antitoxinas/sangue , Toxinas Bacterianas/imunologia , Surtos de Doenças , Animais , Anticorpos Antibacterianos/sangue , Anticorpos Neutralizantes/sangue , Bangladesh/epidemiologia , Humanos , Imunoglobulina G/sangue , Dermatopatias Bacterianas
2.
J Immunol Methods ; 333(1-2): 89-106, 2008 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-18304568

RESUMO

Quantification of anthrax lethal toxin (LTx) neutralization activity (TNA) is pivotal in assessing protective antibody responses to anthrax vaccines and for evaluation of immunotherapies for anthrax. We have adapted and redesigned the TNA assay to establish a unifying, standardized, quantitative and validated technology platform for LTx neutralization in the J774A.1 murine cell line. Critical design features of this platform are 1) the application of a free-form or constrained 4 parameter logistic (4-PL) function to model neutralization responses within and between boundary limits of 100% cell survival and 95% cell lysis and 2) to exploit innovative assay curve recognition algorithms for interpretive endpoints. The assay was validated using human serum ED50 (dilution of serum effecting 50% neutralization) as the primary reportable value (RV). Intra-operator and intermediate precision, expressed as the coefficient of variation (%CV), were high at 10.5-15.5%CV and 13.5-14.5%CV respectively. TNA assay dilutional linearity was demonstrated for human sera using linear regression analysis of log(10) transformed data with slope=0.99, intercept=-0.03 and r(2)=0.985. Assay accuracy, inferred from the precision and linearity data and using a spike-recovery approach, was high with a percent error (%E) range of only 3.4-20.5%E. The lower limit of detection (LLOD) was ED50=12 and the lower limit of quantification (LLOQ) was ED50=36. The cell-based assay was robust, tolerating incubation temperatures from 35 to 39 degrees C, CO(2) concentrations from 3% to 7% and reporter substrate (MTT) concentrations of 2.5-7.5 mg/ml. Strict assay quality control parameters were met for up to 25 cell culture passages. The long term (50 month) assay stability, determined using human reference standards AVR414 and AVR801, indicated high precision, consistent accuracy and no detectable assay drift. A customized software program provided two additional assay metrics, Quantification Titer (QT) and Threshold Titer (TT), both of which demonstrate acceptable accuracy, precision and dilutional linearity. The TT was also used to establish the assay reactivity threshold (RT). The application of the assay to sera from humans, Rhesus macaques and rabbits was demonstrated separately and by aggregate dilutional linearity analysis of the ED50 (slope=0.98, intercept=0.003, r(2)=0.989). We propose this TNA assay format with a qualified standard reference serum and customized interpretive software as a unifying platform technology for determination of functional serologic responses to anthrax vaccines and for evaluation of anthrax immunotherapeutics.


Assuntos
Antraz/imunologia , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Bacillus anthracis/imunologia , Toxinas Bacterianas/imunologia , Modelos Imunológicos , Testes de Neutralização/métodos , Animais , Antraz/prevenção & controle , Vacinas contra Antraz/imunologia , Linhagem Celular , Humanos , Macaca mulatta , Camundongos , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...