Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Biomater ; 159: 394-409, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36669547

RESUMO

Vagus nerve stimulation (VNS) is being actively explored as a treatment for multiple conditions as part of bioelectronic medicine research. Reliable and safe VNS in mouse models is a critical need for understanding mechanisms of these. We report on the development and evaluation of a microfabricated cuff electrode (MouseFlex) constructed of polyimide (PI) and with iridium oxide (IrOx) electrodes that is thermoformed to 86 µm ± 12 µm radius to interface the mouse cervical vagus nerve (r ≈ 50 µm). Innovative bench-top methods were used to evaluate the stimulation stability and electrochemical properties of electrodes. Our aggressive stimulation stability (Stim-Stab) test utilized 1 billion pulses at a 1000 Hz with a current density of 6.28 A/cm2 (1.51 mC/cm2/phase) delivering 3023 × 103 C/cm2 to evaluate electrode lifetimes, and all electrodes remained functional. We also investigated the effects of thermoforming on their impedance, charge storage capacity (CSC), and charge injection capacity (CIC). The modest changes in electrochemical properties indicate that the thermoforming process was well tolerated. Thermoformed electrode safety and efficacy were evaluated in-vivo by performing acute VNS in mice and monitoring their heart and respiration rate as biomarkers. Their electrochemical properties were also measured before, during and after VNS. Bradycardia and bradypnea were reliably induced at stimulation currents of 100 to 200 µA, well below the in-vivo CIC of ∼1250 µA (∼0.5 mC/cm2), supporting their safety and efficacy. The electrode impedance increased and CIC decreased during in-vivo use, but largely reversed these changes in in-vitro testing after enzymatic cleaning, supporting their tolerance for surgical use. STATEMENT OF SIGNIFICANCE: Vagus nerve stimulation (VNS) is a rapidly growing aspect of healthcare and bioelectronic medicine research. Reliable and safe VNS in mice with small diameter (d ≈ 100 µm) nerves has been a challenge due to achieving intimate contact with the nerve, and the stimulation stability of commonly used electrodes. We demonstrate a microfabricated (MouseFlex) cuff electrode constructed of polyimide with IrOx electrodes that is thermoformed to contact the mouse cervical vagus. Bench studies highlight the stimulation stability exceeded 109 pulses at 6.28 A/cm2 and their electrochemical properties were measured before, during, and after bench and nerve stimulation. Nerve stimulation induced bradycardia and bradypnea at currents below the in-vivo charge injection capacity, supporting their safety, efficacy, and tolerance for surgical handling.


Assuntos
Estimulação do Nervo Vago , Camundongos , Animais , Estimulação do Nervo Vago/métodos , Bradicardia , Eletrodos , Nervo Vago/fisiologia , Coração , Estimulação Elétrica
2.
Biosens Bioelectron ; 200: 113886, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34995836

RESUMO

Novel research in the field of bioelectronic medicine requires neuromodulation systems that pair high-performance neurostimulation and bio-signal acquisition hardware with advanced signal processing and control algorithms. Although mice are the most commonly used animal in medical research, the size, weight, and power requirements of such bioelectronic systems either preclude use in mice or impose significant constraints on experimental design. Here, a fully-implantable recording and stimulation neuromodulation system suitable for use in mice is presented, measuring 2.2 cm3 and weighing 2.8 g. The bidirectional wireless interface allows simultaneous readout of multiple physiological signals and complete control over stimulation parameters, and a wirelessly rechargeable battery provides a lifetime of up to 5 days on a single charge. The device was implanted to deliver vagus nerve stimulation (n = 12 animals) and a functional neural interface (capable of inducing acute bradycardia) was demonstrated with lifetimes exceeding three weeks. The design utilizes only commercially-available electrical components and 3D-printed packaging, with the goal of facilitating widespread adoption and accelerating discovery and translation of future bioelectronic therapeutics.


Assuntos
Técnicas Biossensoriais , Tecnologia sem Fio , Animais , Fontes de Energia Elétrica , Camundongos , Próteses e Implantes , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...