1.
Mol Genet Metab ; 110(1-2): 102-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23746553

RESUMO

OBJECTIVE: Prompt ascertainment is crucial for the management of hyperammonemic infants. Because these patients are rare and recognition of hyperammonemia is often delayed, we designed and implemented an electronic medical record (EMR)-based tool to assist physicians in the detection of hyperammonemia. METHODS: We retrospectively evaluated the hospitalizations of prior hyperammonemic infants to identify codable elements that could trigger an EMR-based warning. An alert was designed and implemented and its utilization was prospectively analyzed. RESULTS: Blood gas studies were obtained universally and early in the retrospectively evaluated infants (x¯=26h before ammonia level). Prompting physicians to evaluate ammonia after ordering blood gas studies would have accelerated the initial ammonia order in 89% of retrospective cases. The alert has activated 184 times over the first six months of operation leading to 63 laboratory evaluations and detection of one hyperammonemic infant. CONCLUSION: Implementation of an EMR-based warning system can improve surveillance for hyperammonemia in a susceptible population.


Assuntos
Amônia/metabolismo , Registros Eletrônicos de Saúde , Hiperamonemia/diagnóstico , Ureia/metabolismo , Monitoramento Epidemiológico , Feminino , Humanos , Hiperamonemia/metabolismo , Hiperamonemia/patologia , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...