1.
Phys Eng Sci Med ; 47(1): 181-186, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38048014

RESUMO

A manufacturer has released a novel shielding solution (NSS): Rampart M1128 and claimed that the personal protective equipment (PPE) can be removed. This study investigates the scatter intensities with the NSS or the traditional shielding solutions (TSS) including the ceiling-suspended screen and the tableside lead drape. Isodose maps were generated by two series of measurements with an anthropomorphic phantom using NSS and TSS. Three survey meters were positioned at different heights to measure the scatter intensities at the eye, chest, and pelvic levels. Additional measurements were made at the primary and secondary operators? locations to evaluate the scatter intensities with different clinical projections. For the main operator positions, the isodose maps showed that NSS could result in a scatter dose that reduced by 80% to 95% compared to the same positions with TSS at the eye and chest levels. The corresponding result at the pelvic level was a reduction of 50%. These reductions should be compared to the additional protection by PPE: up to 80% reduction from lead eyeglasses and up to 95% from protective garments. Considering both operators at clinically relevant LAO projections, NSS resulted in scatter dose that was 80% to 96%, 76% to 96% and 25% to 60% lower than those of the TSS at eye, chest and pelvis levels. The protection of NSS is comparable with that of TSS alongside PPE at the eye but not at the chest and the pelvic levels under the setup of coronary angiography.


Assuntos
Proteção Radiológica , Doses de Radiação , Proteção Radiológica/métodos , Cateteres Cardíacos , Angiografia Coronária , Equipamentos de Proteção
2.
Am J Cardiol ; 203: 429-435, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37536045

RESUMO

Continuous exposure to low-level scattered radiation to staff performing cardiac angiography and intervention is of concern. A novel shielding solution (NSS) (Rampart IC M1128) has the potential to provide greater shielding for staff present at the table-side. This study aimed to investigate the effectiveness of the NSS compared with a traditional shielding solution (TSS) in a randomized controlled trial that enrolled 100 patients who underwent cardiac angiography and/or intervention which were randomized to the NSS or TSS. Baseline patient characteristics and radiation dose data were collected. Staff who were scrubbed at the table-side wore 5 real-time dosimeters on the head, collar, waist, ankle, and under the apron. The median primary operator radiation dose was significantly lower (p <0.001) for all dosimeter locations with the NSS when compared with the TSS, being reduced by 86%, 80.0%, 100%, and 50.0% for the head, collar, waist, and leg respectively. Median under-apron dose was 0.0 µSv for both NSS and TSS. Median second operator dose was reduced by 100%, 100%, and 100% for the head, collar, and waist respectively (p <0.001). Median NSS and TSS dose at the ankle and under apron was 0.0 µSv. Median scrub nurse dose was reduced by 50% and 100% for the head and collar respectively (p <0.001). Median NSS and TSS dose at the waist, ankle, and under apron was 0.0 µSv. In conclusion, the NSS tested in this study demonstrates a significant decrease in radiation dose to operators and scrub nurses when compared with traditional radiation protection measures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Cateteres Cardíacos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle
3.
Heart Lung Circ ; 31(3): 372-382, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34654649

RESUMO

AIMS: This study sought to investigate patient and operator radiation dose in patients undergoing percutaneous coronary intervention (PCI) and the impact of body mass index (BMI) on patient and operator dose. METHODS: In patients undergoing PCI, radiation dose parameters, baseline characteristics and procedural data were collected in a tertiary centre for 3.5 years. Operators wore real time dosimeters. Patients were grouped by BMI. Dose area product (DAP) and operator radiation dose were compared across patient BMI categories. Multivariable analysis was performed to investigate the impact of patient BMI and other procedural variables on patient and operator dose. RESULTS: 2,043 patients underwent 2,197 PCI procedures. Each five-unit increase in BMI increased patient dose (expressed as DAP) by an average 31% (95% CI: 29-33%) and operator dose by 27% (95% CI: 20-33%). Patient dose was 2.3 times higher and operator dose was 2.4 times higher in patients with a BMI>40 than for normal BMI patients. Multivariable analysis indicated that there were many procedural factors that were predictors for increasing operator dose and patient dose but that patient BMI was a major contributor for both operator dose and patient dose. CONCLUSION: Increasing BMI increases the DAP and operator dose for PCI procedures and BMI is demonstrated to be a major factor that contributes to both patient and operator radiation dose.


Assuntos
Intervenção Coronária Percutânea , Exposição à Radiação , Índice de Massa Corporal , Angiografia Coronária/efeitos adversos , Humanos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Fatores de Risco
4.
Sci Rep ; 10(1): 13314, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32769994

RESUMO

The first 8 weeks of pregnancy is a critical time, with the majority of pregnancy losses occurring during this period. Abnormal chromosome number (aneuploidy) is a common finding in human miscarriage, yet is rarely reported in domestic animals. Equine early pregnancy loss (EPL) has no diagnosis in over 80% of cases. The aim of this study was to characterise aneuploidies associated with equine EPL. Genomic DNA from clinical cases of spontaneous miscarriage (EPLs; 14-65 days of gestation) and healthy control placentae (various gestational ages) were assessed using a high density genotyping array. Aneuploidy was detected in 12/55 EPLs (21.8%), and 0/15 healthy control placentae. Whole genome sequencing (30X) and digital droplet PCR (ddPCR) validated results. The majority of these aneuploidies have never been reported in live born equines, supporting their embryonic/fetal lethality. Aneuploidies were detected in both placental and fetal compartments. Rodents are currently used to study how maternal ageing impacts aneuploidy risk, however the differences in reproductive biology is a limitation of this model. We present the first evidence of aneuploidy in naturally occurring equine EPLs at a similar rate to human miscarriage. We therefore suggest the horse as an alternative to rodent models to study mechanisms resulting in aneuploid pregnancies.


Assuntos
Aborto Animal/genética , Aneuploidia , Genoma , Doenças dos Cavalos/genética , Aborto Animal/patologia , Animais , Feminino , Estudo de Associação Genômica Ampla , Doenças dos Cavalos/patologia , Cavalos , Gravidez , Sequenciamento Completo do Genoma
5.
Br J Radiol ; 93(1112): 20200018, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32543896

RESUMO

OBJECTIVES: Radiation from cardiac angiography procedures is harmful to patients and the staff performing them. This study sought to investigate operator radiation dose for a range of procedures and different operators in order to investigate trends and optimise dose. METHODS: Real-time dosemeters (RTDs) were worn by operators for angiography procedures for 3 years. Dose-area product (DAP) and RTD were collected. RTD was normalised to DAP (RTD/DAP) to compare radiation dose and radiation protection measures. Comparisons were made across procedure categories and individual operators. RESULTS: In 7626 procedures, median and 75th percentile levels were established for operator dose for 8 procedure categories. There was a significant difference in all operator dose measures and DAP across procedure categories (p<0.001). DAP, RTD, and RTD/DAP were significantly different across 22 individual operators (p<0.001). CONCLUSION: DAP was significantly different across procedure categories and a higher RTD was seen with higher DAP. RTD/DAP can demonstrate radiation protection effectiveness and identified differences between procedures and individual operators with this measure. Procedures and individuals were identified where further optimisation of radiation protection measures may be beneficial. A reference level for operator dose can be created and audited against on a regular basis. ADVANCES IN KNOWLEDGE: This study demonstrates that operator dose can be easily and routinely measured on a case by case basis to investigate dose trends for different procedures. Normalising the operator dose to DAP demonstrates radiation protection effectiveness for the individual operator which can then be optimised as part of an ongoing audit program.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Exposição Ocupacional/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Pessoal de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Dosímetros de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiografia Intervencionista/métodos , Estudos Retrospectivos
6.
Eur Heart J Case Rep ; 3(2)2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31449617

RESUMO

BACKGROUND: Three-dimensional (3D) printing of cardiac fistulae allows for immediate understanding of their complex courses and anatomical relations. Models can be used to improve patient understanding, enhance the consenting process, facilitate communication between multidisciplinary staff at heart team meetings, and help plan surgical or percutaneous interventions. CASE SUMMARY: We report four cases where 3D printed models were used as an adjunct with traditional measures in treating patients with complex cardiac fistulae. DISCUSSION: In our cases, overall patient understanding was improved, staff at heart team meetings were more aware of anatomical anomalies and perioperatively planning saw adjustments made that may have ultimately benefited patient outcome. Our cases highlight the additional benefit that 3D printed models can play when treating patients with complex cardiac fistulae.

7.
Br J Radiol ; 92(1093): 20180367, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30209953

RESUMO

OBJECTIVE:: This study compares the performance of bi-plane coronary angiography against single plane angiography in terms of the volume of contrast used (ml) and the total dose-area product (DAP) (µGym2) to the patient measured directly via flat panel detectors. METHODS:: A total of 5176 adult diagnostic cardiac angiograms from a hospital in Brisbane, Australia were retrospectively studied. Patients with aortograms, iliac or femoral artery imaging, and stenting or graft interventions were excluded. Student's t-tests were used to compare means, and confounding variables were compared using multivariate regression. This quantified the effects of bi-plane system use holding constant other factors (e.g.) body mass index (BMI), age, room, sex, number of digital acquisitions and fluoro time. RESULTS:: Bi-plane imaging had an average difference in mean contrast use of -15.1 ml [15.5% 95% confidence interval (CI) (-13.2, -17.0) p<0.001], multivariate regression demonstrated a -27.0 ml reduction in contrast use [28% 95% CI (-29.0, -24.83) p<0.0001] when the significant effects of fluoro time, number of digital acquisitions, BMI and sex were held constant. Bi-plane imaging had an average difference in mean DAP of + 887.1 µGym2 [23% 95% CI (+1110.7, +663.4) p < 0.001], whilst multivariate regression found a +628.3 Gym2 increase in DAP [16% 95% CI (+467.5, +789.3) p<0.001] when the significant effects of fluoro time, number of digital acquisitions, BMI and sex were held constant. CONCLUSION:: These results demonstrate that bi-plane imaging uses less contrast media than single-plane imaging for coronary angiography at the expense of more radiation. Bi-plane imaging may be preferable in patients with renal impairment, however single plane imaging may be preferable in those without renal impairment. ADVANCES IN KNOWLEDGE:: This is a large cohort and statistically comprehensive study comparing bi-plane and single plane coronary angiography. Other studies 4, 5, 6, 12 have used Student's t-tests to measure the difference between means, however this provides no causative information on the differences found. This study provides a view of the causative impact of bi-plane usage on DAP and contrast use via multivariate regression modelling.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Austrália , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fatores de Risco
8.
J Med Radiat Sci ; 66(1): 20-29, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30488575

RESUMO

INTRODUCTION: Diagnostic coronary angiography (CA) uses ionising radiation with relatively high doses, which impact on both patients and staff. This study sought to identify which patient and procedural factors impact patient and operator dose the most during CA. METHODS: Patient and procedure related variables impacting on Kerma area product (PKA ) and operator dose (OD) were collected for 16 months. Procedures were separated into 10 different procedure categories. PKA was used for patient dose and OD was measured with an instantly downloadable dosimeter (IDD) - downloaded at the end of each procedure. High and low radiation dose was defined by binary variables based on the 75th percentile of the continuous measures. Univariate and multivariate regression were used to identify predictors. RESULTS: Of 3860 patients included, the IDD was worn for 2591 (61.7%). Obesity (BMI > 30 compared to BMI < 25) was the strongest predictor for both a PKA (odds ratio (OR) = 19.1 (95% CI 13.5-26.9) P < 0.001) and OD (OR = 3.3 (2.4-4.4) P < 0.001) above the 75th percentile. Male gender, biplane imaging, the X-ray unit used, operator experience and procedure type also predicted a high PKA . Radial access, male gender, biplane imaging and procedure type also predicted a high OD. CONCLUSION: Radiation dose during CA is multifactorial and is dependent on patient and procedure related variables. Many factors impact on both PKA and OD but obesity is the strongest predictor for both patients and operators to receive a high radiation dose.


Assuntos
Angiografia Coronária , Exposição Ocupacional/análise , Doses de Radiação , Exposição à Radiação/análise , Idoso , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Proteção Radiológica , Estudos Retrospectivos
9.
J Med Radiat Sci ; 65(4): 247-249, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30506849

RESUMO

Radiation dose to patients undergoing cardiac imaging procedures in cardiac catheterisation laboratories (cath labs) can be relatively high, so implementing strategies to reduce dose is important. Lowering the fluoroscopy pulse rate is a simple, yet effective method to reduce radiation dose. Sensible, iterative changes made in this area have the potential for significant patient and staff radiation dose reduction.


Assuntos
Fluoroscopia/métodos , Doses de Radiação , Fenômenos Eletrofisiológicos , Fluoroscopia/efeitos adversos , Humanos , Exposição Ocupacional/prevenção & controle
10.
J Am Coll Cardiol ; 71(11): 1246-1254, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-29544609

RESUMO

BACKGROUND: Transesophageal echocardiography operators (TEEOP) provide critical imaging support for percutaneous structural cardiac intervention procedures. They stand close to the patient and the associated scattered radiation. OBJECTIVES: This study sought to investigate TEEOP radiation dose during percutaneous structural cardiac intervention. METHODS: Key personnel (TEEOP, anesthetist, primary operator [OP1], and secondary operator) wore instantly downloadable personal dosimeters during procedures requiring TEE support. TEEOP effective dose (E) and E per unit Kerma area product (E/KAP) were calculated. E/KAP was compared with C-arm projections. Additional shielding for TEEOP was implemented, and doses were measured for a further 50 procedures. Multivariate linear regression was performed to investigate independent predictors of radiation dose reduction. RESULTS: In the initial 98 procedures, median TEEOP E was 2.62 µSv (interquartile range [IQR]: 0.95 to 4.76 µSv), similar to OP1 E: 1.91 µSv (IQR: 0.48 to 3.81 µSv) (p = 0.101), but significantly higher than secondary operator E: 0.48 µSv (IQR: 0.00 to 1.91 µSv) (p < 0.001) and anesthetist E: 0.48 µSv (IQR: 0.00 to 1.43 µSv) (p < 0.001). Procedures using predominantly right anterior oblique (RAO) and steep RAO projections were associated with high TEEOP E/KAP (p = 0.041). In a further 50 procedures, with additional TEEOP shielding, TEEOP E was reduced by 82% (2.62 µSv [IQR: 0.95 to 4.76] to 0.48 µSv [IQR: 0.00 to 1.43 µSv] [p < 0.001]). Multivariate regression demonstrated shielding, procedure type, and KAP as independent predictors of TEEOP dose. CONCLUSION: TEE operators are exposed to a radiation dose that is at least as high as that of OP1 during percutaneous cardiac intervention. Doses were higher with procedures using predominantly RAO projections. Radiation doses can be significantly reduced with the use of an additional ceiling-suspended lead shield.


Assuntos
Ecocardiografia Transesofagiana , Exposição Ocupacional , Intervenção Coronária Percutânea/métodos , Exposição à Radiação , Proteção Radiológica/métodos , Austrália , Ecocardiografia Transesofagiana/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde , Doses de Radiação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle
11.
Pacing Clin Electrophysiol ; 40(8): 947-954, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28618036

RESUMO

BACKGROUND: Electrophysiology procedures require fluoroscopic guidance, with the associated potentially adverse effects of ionizing radiation. Newer fluoroscopy systems have more features that enable dose-reduction strategies. This study aimed to investigate any reduction in radiation dose between an older fluoroscopy system (Philips Integris H5000, Philips Healthcare, Einhoven, Netherlands) and one of the latest systems (Siemens Artis Q, Siemens Healthcare, Erlangen, Germany), optimized with dose-reduction strategies. METHODS: Radiation dose measures were collected over a 2-year period in a single electrophysiology laboratory. Procedures were separated into seven groups: devices, biventricular devices, electrophysiology studies, standard radiofrequency ablation, complex atrial ablation, ablation for ventricular arrhythmias, and pulmonary vein isolation. In the first year, an older fluoroscopy system was used, and in the second year, a new system, with dose reduction strategies. Comparisons were also made to the literature with regard to radiation dose levels. RESULTS: Patient characteristics, fluoroscopy times, number of digital acquisitions, procedural times, and procedural success were largely similar between the old and new system across procedure groups. Overall dose area product (DAP) was reduced by 91% (5.0 [2.0-17.0] to 0.45 [0.16-2.61] Gycm2 [P > 0.001]) with the new system and was lower across all groups. DAP readings with the new system are some of the lowest published in the literature in all groups. CONCLUSION: An optimized contemporary digital fluoroscopy system, with low radiation dose configuration and continued good procedural practice, can result in ultra-low radiation levels for all electrophysiology procedures, without compromising procedural time or procedural success.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Fluoroscopia/métodos , Doses de Radiação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
Heart Lung Circ ; 25(3): 282-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26672437

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) patients are at a high risk of acute kidney injury (AKI). This study aimed to investigate AKI and the relationship with iodinated contrast media (ICM), whether there are significant pre- or peri- procedural variables predicting AKI, and whether AKI impacts on hospital length of stay and mortality. METHODS: Serum creatinine (SC) levels pre- and post- (peak) TAVR were recorded in 209 consecutive TAVR patients. AKI was defined by the Valve Academic Research Consortium 2 (VARC2) criteria. Baseline characteristics, procedural variables, hospital length of stay (LOS) and mortality at 72hours, 30 days and one year were analysed. RESULTS: Eighty-two of 209 (39%) patients suffered AKI. Mean ICM volume was 228cc, with no difference between patients with AKI and those with no AKI (227cc (213-240(95%CI)) vs 231cc (212-250) p=0.700)). Univariate and multivariate analysis demonstrated that chronic kidney disease, respiratory failure, previous stroke, the need for blood transfusion and valve repositioning were all predictors of AKI. Acute kidney injury increased LOS (5.6 days (3.8 - 7.5) vs 3.2 days (2.6 - 3.9) no AKI (P=0.004)) but was not linked to increased mortality. Mortality rates did increase with AKI severity. CONCLUSION: Acute kidney injury is a common complication of TAVR. The severity of AKI is important in determining mortality. Acute kidney injury appears to be independent of ICM use but pre-existing renal impairment and respiratory failure were predictors for AKI. Transcatheter aortic valve replacement device repositioning or retrieval was identified as a new risk factor impacting on AKI.


Assuntos
Injúria Renal Aguda/mortalidade , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/sangue , Injúria Renal Aguda/etiologia , Idoso de 80 Anos ou mais , Creatinina/sangue , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/sangue , Fatores de Risco
13.
J Med Radiat Sci ; 62(4): 239-45, 2015 12.
Artigo em Inglês | MEDLINE | ID: mdl-27512569

RESUMO

INTRODUCTION: Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. METHODS: Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. RESULTS: When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. CONCLUSION: Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.


Assuntos
Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Cirurgia Assistida por Computador/métodos , Valva Aórtica/diagnóstico por imagem , Humanos , Radiografia/métodos , Radiografia/normas , Cirurgia Assistida por Computador/normas , Raios X
14.
Cardiovasc Revasc Med ; 15(8): 388-92, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25456416

RESUMO

BACKGROUND: Patients with degenerated surgical bioprosthetic valves may be at high risk for further surgery because of age, comorbidities and the difficulties of repeat procedures. Percutaneous valve-in-valve implantation offers what may be a simpler and safer procedure. METHODS: From May 2009 to March 2014 at the Prince Charles Hospital 1625 patients underwent surgical aortic valve replacement while 262 underwent transcatheter aortic valve implantation. Twelve patients had valve-in-valve implants for degenerated bioprosthetic aortic valves. RESULTS: These implants were deployed successfully without major valvular or paravalvular regurgitation. There were no periprocedural deaths, myocardial infarcts, neurological events or major vascular complications. Two patients died after 1624 and 1319days. Median survival for the remainder is 581days; they are stable with New York Heart Association class I/II functional status although 4 have a degree of patient-prosthesis mismatch, one has moderate aortic regurgitation and one required surgery for a late aortic dissection. CONCLUSION: Transcatheter valve-in-valve implantation is safe and effective treatment for patients with failed bioprosthetic aortic valves for whom reoperation is considered to be hazardous.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/fisiopatologia , Austrália , Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Resultado do Tratamento
15.
J Med Radiat Sci ; 61(3): 135-41, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26229649

RESUMO

INTRODUCTION: Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. METHODS: Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P KA), skin surface entrance dose (K AR), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P KA. RESULTS: 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3-6.1). Median K AR = 581 mGy (374-876). Median P KA = 3908 uGym(2) (2489-5865) DRL = 5865 uGym(2). 947 patients were included in the PCI group where median FT was 11.2 min (7.7-17.4). Median K AR = 1501 mGy (928-2224). Median P KA = 8736 uGym(2) (5449-12,900) DRL = 12,900 uGym(2). CONCLUSION: This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.

16.
Int J Cardiovasc Imaging ; 29(7): 1537-45, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23925712

RESUMO

Adequate vascular access for femoral trans-catheter aortic valve replacement is fundamental to the success of the procedure. Assessment of vascular calibre, tortuosity and calcification is performed by angiography and multi-slice computed tomography (MSCT). Can DynaCT provide the same information as MSCT? 15 Patients underwent MSCT, angiography and DynaCT. Vessel diameter measurements were taken in three positions of the left and right ilio-femoral arteries. Tortuosity was assessed using an index of the direct distance and the distance taken by the artery between two points. Calcification was assessed in MSCT and DynaCT using a simple scoring system. Concordance correlation coefficient of arterial calibre between angiography and MSCT was 0.96 (95 % CI 0.94-0.97). DynaCT and angiography was 0.94 (95 % CI 0.91-0.96) and Dyna CT and MSCT, 0.95 (95 % CI 0.92-0.97). Bland-Altman tests demonstrate a mean difference between the angiogram and the MSCT of 0.06 mm (+0.97, -1.42), angiogram and DynaCT, 0.13 mm, (+1.00, -0.87), DynaCT and MSCT, 0.2 mm, (+1.15, -0.76). Tortuosity comparisons gave a median tortuosity index for MSCT 1.29 and DynaCT 1.23 (p = 0.472). Calcification comparisons of MSCT and DynaCT using correlation coefficients demonstrate a correlation of 0.245 (p = 0.378). Effective radiation doses were: DynaCT; 3.63 ± 0.65 mSv and angiography; 0.57 ± 0.72 mSv, MSCT; 7.15 ± 2.58 mSv. DynaCT is equal to MSCT and angiography in assessing femoral artery calibre. Like MSCT, it can assess tortuosity and can produce 3D images but is inferior in the assessment of calcification.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Artéria Femoral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Calcificação Vascular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Masculino , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença
19.
J Med Radiat Sci ; 60(2): 67-70, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26229610

RESUMO

A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. This case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.

20.
EuroIntervention ; 8(5): 538-45, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22995079

RESUMO

AIMS: The clinical value of optimising implant angles during transcatheter aortic valve replacements (TAVR) remains undefined. The Aortic Valve Guide (AVG) is a proprietary software that provides structured analysis of three-dimensional images from rotational angiography (DynaCT). This study compares AVG with preprocedural multislice computed tomography (MSCT) and DynaCT in optimal implant angle prediction for TAVR, and evaluates if an optimised implant angle is associated with reduced paravalvular regurgitation (PVR). METHODS AND RESULTS: One hundred and six consecutive patients were included, comprising three groups. Group 1 (n=19) underwent no preprocedural MSCT or DynaCT (or AVG); Group 2 (n=44) underwent periprocedural DynaCT, without AVG; Group 3 (n=43) had DynaCT with AVG. Implant angles yielded were graded as excellent, satisfactory or poor. Group 3 were more likely than Groups 2 and 1 to have excellent implant angles (83.7% vs. 52.3% vs. 42.1%, respectively, p=0.001). In 100 patients who had 30-day transthoracic echocardiogram follow-up, an excellent implant angle was significantly more likely to be associated with no PVR than a non-excellent angle (41.3% vs. 21.6%, respectively, p=0.045), independent of operator experience and THV used. CONCLUSIONS: Optimising implant angles may be important in reducing PVR. This is significantly more likely to be achieved with AVG rotational angiography.


Assuntos
Angiografia/métodos , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fluoroscopia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Imageamento Tridimensional/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...