Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(24)2022 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-36560066

RESUMO

Frequency-modulated continuous wave (FMCW) radars are currently being investigated for remote vital signs monitoring (measure of respiration and heart rates) as an innovative wireless solution for healthcare and ambient assisted living. However, static reflectors (furniture, objects, stationary body parts, etc.) within the range or range angular bin where the subject is present contribute in the Doppler signal to a direct current (DC) offset. The latter is added to the person's information, containing also a useful DC component, causing signal distortion and hence reducing the accuracy in measuring the vital sign parameters. Removing the sole contribution of the unwanted DC offset is fundamental to perform proper phase demodulation, so that accurate vital signs monitoring can be achieved. In this work, we analyzed different DC offset calibration methods to determine which one achieves the highest accuracy in measuring the physiological parameters as the transmitting frequency varies. More precisely, by using two FMCW radars, operating below 10 GHz and at millimeter wave (mmWave), we applied four DC offset calibration methods to the baseband radar signals originated by the cardiopulmonary activities. We experimentally determined the accuracy of the methods by measuring the respiration and the heart rates of different subjects in an office setting. It was found that the linear demodulation outperforms the other methods if operating below 10 GHz while the geometric fitting provides the best results at mmWave.


Assuntos
Radar , Processamento de Sinais Assistido por Computador , Humanos , Monitorização Fisiológica/métodos , Sinais Vitais , Respiração , Frequência Cardíaca/fisiologia , Algoritmos
2.
Sensors (Basel) ; 22(24)2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36560268

RESUMO

Unmanned ground vehicles (UGVs) find extensive use in various applications, including that within industrial environments. Efforts have been made to develop cheap, portable, and light-ranging/positioning systems to accurately locate their absolute/relative position and to automatically avoid potential obstacles and/or collisions with other drones. To this aim, a promising solution is the use of ultrasonic systems, which can be set up on UGVs and can potentially output a precise reconstruction of the drone's surroundings. In this framework, a so-called frequency-modulated continuous wave (FMCW) scheme is widely employed as a distance estimator. However, this technique suffers from low repeatability and accuracy at ranges of less than 50 mm when used in combination with low-resource hardware and commercial narrowband transducers, which is a distance range of the utmost importance to avoid potential collisions and/or imaging UGV surroundings. We hereby propose a modified FMCW-based scheme using an ad hoc time-shift of the reference signal. This was shown to improve performance at ranges below 50 mm while leaving the signal unaltered at greater distances. The capabilities of the modified FMCW were evaluated numerically and experimentally. A dramatic enhancement in performance was found for the proposed FMCW with respect to its standard counterpart, which is very close to that of the correlation approach. This work paves the way for the future use of FMCWs in applications requiring high precision.

3.
Sci Rep ; 12(1): 7651, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35538128

RESUMO

In light of the continuously and rapidly growing senior and geriatric population, the research of new technologies enabling long-term remote patient monitoring plays an important role. For this purpose, we propose a single-input-multiple-output (SIMO) frequency-modulated continuous wave (FMCW) radar system and a signal processing technique to automatically detect the number and the 2-D position (azimuth and range information) of stationary people (seated/lying down). This is achieved by extracting the vital signs signatures of each single individual, separating the Doppler shifts caused by the cardiopulmonary activities from the unwanted reflected signals from static reflectors and multipaths. We then determine the number of human subjects present in the monitored environment by counting the number of extracted vital signs signatures while the 2-D localization is performed by measuring the distance from the radar where the vital signs information is sensed (i.e., locating the thoracic region). We reported maximum mean absolute errors (MAEs) of 0.1 m and 2.29[Formula: see text] and maximum root-mean-square errors (RMSEs) of 0.12 m and 3.04[Formula: see text] in measuring respectively the ranges and azimuth angles. The experimental validation demonstrated the ability of the proposed approach in monitoring paired human subjects in a typical office environment.


Assuntos
Algoritmos , Radar , Idoso , Frequência Cardíaca , Humanos , Monitorização Fisiológica/métodos , Processamento de Sinais Assistido por Computador , Sinais Vitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...