Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gels ; 8(6)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35735704

RESUMO

Poloxamer is a triblock copolymer with amphiphilicity and reversible thermal responsiveness and has wide application prospects in biomedical applications owing to its multifunctional properties. Poloxamer hydrogels play a crucial role in the field of tissue engineering and have been regarded as injectable scaffolds for loading cells or growth factors (GFs) in the last few years. Hydrogel micelles can maintain the integrity and stability of cells and GFs and form an appropriate vascular network at the application site, thus creating an appropriate microenvironment for cell growth, nerve growth, or bone integration. The injectability and low toxicity of poloxamer hydrogels make them a noninvasive method. In addition, they can also be good candidates for bio-inks, the raw material for three-dimensional (3D) printing. However, the potential of poloxamer hydrogels has not been fully explored owing to the complex biological challenges. In this review, the latest progress and cutting-edge research of poloxamer-based scaffolds in different fields of application such as the bone, vascular, cartilage, skin, nervous system, and organs in tissue engineering and 3D printing are reviewed, and the important roles of poloxamers in tissue engineering scaffolds are discussed in depth.

2.
Molecules ; 27(6)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35335291

RESUMO

In this study, density functional theory was employed to calculate the adsorption of polycaprolactone (PCL) by pure hydroxyapatite (HA), Zn-doped HA, and Ag-doped HA, and the interaction of PCL on the surface of HA (001) was simulated. The results show that there was significant electron transfer between the carbonyl O in PCL and the Zn, Ag, and Ca in HA, forming coordinate bonds. The binding energies of Ag-doped HA/PCL and Zn-doped HA/PCL were much higher than those of HA/PCL. HA doped with Ag had the highest binding energy to PCL. Therefore, we believe that when HA is doped with Ag atoms, its adsorption capacity for PCL can be increased. The results obtained in this study can be used as a guide for the development of HA/PCL bone graft composite material doped with appropriate metal ions to improve its adsorption capacity.


Assuntos
Durapatita , Polímeros , Poliésteres , Zinco
3.
Nanomaterials (Basel) ; 12(3)2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35159828

RESUMO

Graphene can be used as a drug carrier of doxorubicin (DOX) to reduce the side effects of doxorubicin. However, there is limited research on the surface chemical modifications and biological effects of graphene oxide (GO). Therefore, it is necessary to explore the DOX affinity of different oxygen-containing functional groups in the graphene system. We constructed graphene system models and studied the structure and distribution of epoxy and hydroxyl groups on the carbon surface. Based on molecular dynamics simulations and density functional theory (DFT), we investigated the interaction between DOX and either pristine graphene or GO with different ratios of oxygen-containing groups. The hydroxyl groups exhibited a stronger affinity for DOX than the epoxy groups. Therefore, the DOX loading capacity of graphene systems can be adjusted by increasing the ratio of hydroxyl to epoxy groups on the carbon surface.

4.
Materials (Basel) ; 15(3)2022 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-35160743

RESUMO

Owing to the limitations of traditional systemic drug delivery in the treatment of bone diseases with side effects on normal cells, the selection of materials with high affinities for bones, as targeting ligands to modify drug carriers, has become an important research topic. Tetracyclines (TCs) have an adsorption effect on hydroxyapatite (HAp). Thus, they can be used as bone-targeting ligands and combined with drug carriers. In this study, density functional theory is used to analyze the interaction mechanism of TC, oxytetracycline (OTC), chlortetracycline, and HAp. We calculate the electrostatic potential (ESP) and molecular orbitals to predict the possible binding sites of TCs on the HAp surface. The adsorption energy is used to compare the affinities of the three TCs to HAp. An independent gradient model analysis is performed to study the weak interaction between TCs and HAp. The coordination bond between TCs and the HAp surface is evaluated by conducting a charge density difference analysis. The results show that OTC has the highest affinity to HAp because the introduction of hydroxyl groups change the adsorption configuration of OTC. Thus, OTC adsorbed on HAp in a broken-line shape exposes more binding sites. This study provides a theoretical basis for TCs as bone-targeting ligands in treating bone diseases and in improving the safety of treatment by selecting different bone-targeting ligands.

5.
Materials (Basel) ; 14(16)2021 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-34443046

RESUMO

In this review, we describe the application of thermosensitive hydrogels composed of poloxamer in medicine, especially for oral cavities. Thermosensitive hydrogels remain fluid at room temperature; at body temperature, they become more viscous gels. In this manner, the gelling system can remain localized for considerable durations and control and prolong drug release. The chemical structure of the poloxamer triblock copolymer leads to an amphiphilic aqueous solution and an active surface. Moreover, the poloxamer can gel by forming micelles in an aqueous solution, depending on its critical micelle concentration and critical micelle temperature. Owing to its controlled-release effect, a thermosensitive gel based on poloxamer 407 (P407) is used to deliver drugs with different characteristics. As demonstrated in studies on poloxamer formulations, an increase in gelling viscosity decreases the drug release rate and gel dissolution time to the extent that it prolongs the drug's duration of action in disease treatment. This property is used for drug delivery and different therapeutic applications. Its unique route of administration, for many oral diseases, is advantageous over traditional routes of administration, such as direct application and systemic treatment. In conclusion, thermosensitive gels based on poloxamers are suitable and have great potential for oral disease treatment.

6.
Scanning ; 2021: 5535403, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34221213

RESUMO

The spread and application of computer-aided design/computer-aided manufacturing (CAD/CAM) technology have contributed to the rapid development of digitalization in dentistry. The accuracy of scan results is closely related to the devising subsequent treatment plans and outcomes. Professional standards for evaluating scanners are specified in the American National Standard/American Dental Association Standard 132 (ANSI/ADA No. 132). The aims of this study were to use the three samples mentioned in ANSI/ADA No. 132 and evaluate the accuracy and reproducibility of two extraoral scanners and an intraoral scanner based on the inspection standards recommended by ANSI/ADA No. 132. In this study, two trained operators used two extraoral scanners (E4, 3Shape, Denmark & SHINING DS100+, Shining, China) and an intraoral scanner (TRIOS SERIES3, 3Shape, Denmark) to perform 30 scans of each of the three samples at a temperature of 25 ± 2°C and export standard tessellation language files and used reverse engineering software to perform measurements and iterative nearest point matching experiments. The measured values obtained were compared with the reference values measured by a coordinate measuring machine (NC8107, Leader Metrology, USA). We performed a normal distribution test (Shapiro-Wilk test), the nonparametric Kruskal-Wallis test, and an independent-samples t-test to analyze the reproducibility of each scan for different models. The experimental results indicate that the trueness and precision of the two extraoral scanners and the intraoral scanner had a slight mean deviation. The trueness and precision of the three scanners on the curved surface and groove areas are poor. The accuracy and reproducibility of E4 outperformed SHINING and TRIOS. The iterative closest point matching experiment also showed good matching results. The two extraoral scanners and the intraoral scanner in this study can meet the basic clinical requirements in terms of accuracy, and we hope that digital technology will be more widely used in dentistry in the future.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Tecnologia Digital , Reprodutibilidade dos Testes , Software
7.
Scanning ; 2021: 6675604, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33936357

RESUMO

BACKGROUND: Autogenous tooth transplantation is a reliable method for repairing missing teeth. Although it recently became a recognized and feasible treatment method in dentistry, the long-term efficacy of root canal therapy (RCT) has not been well confirmed. This study is aimed at determining whether RCT has a good effect on the success rate of teeth with complete roots in autogenous tooth transplantation. MATERIALS AND METHODS: Data were collected from the Korea University Guro Hospital. Data of patients who underwent autogenous tooth transplantation within 9 years were collected. We selected 29 teeth with complete roots as the research subjects in our study. None of the patients had any systemic diseases. All cases in this study were obtained with patient permission. RESULTS: According to the tooth vitality test, the autogenous teeth tested negative in dental pulp test and function. Nine of the 29 teeth with autogenous tooth transplantation were treated with RCT and survived throughout the observation period. However, 20 autogenous teeth were not treated with RCT, and eight of them did not survive. All statistical analyses were performed using IBM SPSS 20.0. The null hypothesis was rejected (p < 0.05). CONCLUSION: For complete root teeth, the success rate after autogenous tooth transplantation after RCT is higher than that of teeth not treated with RCT.


Assuntos
Tratamento do Canal Radicular , Dente , Humanos , Raiz Dentária/cirurgia , Transplante Autólogo , Resultado do Tratamento
8.
J Mol Graph Model ; 104: 107835, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33444978

RESUMO

Weak interactions play a very important role in the fields of supramolecular chemistry, molecular physics, materials science, etc. They have a great impact on the structure of the compounds in the gas, liquid and solid phases and the mechanism of some reaction processes. In this study, we visualized the intermolecular interactions between H2O and different graphene systems through density functional theory. Because the surface of Graphene oxide (GO) has epoxy groups, hydroxyl groups, and other oxygen-containing groups. These groups are prone to hydrogen bonding with hydrogen atoms of H2O, and we further explain some of them based on the acid-base theory. Also, we obtained the components of interactions between different graphene complex and H2O by energy decomposition. Then we found that for systems with moderate strength hydrogen bonding, such as hydroxyl functional group systems, electrostatic attraction is dominant while the dispersion attraction and induction function play an auxiliary role together.


Assuntos
Grafite , Ligação de Hidrogênio , Radical Hidroxila , Oxigênio , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...