Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(17): e37983, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669375

RESUMO

The purpose of this study is to investigate the serum inflammatory factors in patients with high-altitude polycythemia (HAPC) and their correlation with cognitive function. The subjects were recruited and placed into a HAPC group and control group. Serum samples were collected, and inflammatory factors (interleukin-1beta [IL-1ß], monocyte chemoattractant protein-1 [MCP-1], and tumor necrosis factor-alpha [TNF-α]) were measured using ELISA kits. The mini-mental State Examination (MMSE) was used to assess cognitive function. According to the MMSE scores, HAPC group was further divided into normal cognitive function group (HNCF) and cognitive dysfunction group (HCDF). In comparison with the control group, the MMSE scores in the HAPC group were significantly low (P < .05), whereas the serum levels of IL-1ß, MCP-1, and TNF-α were significantly high (P < .01). Among the HAPC group (n = 60), 21 belonged to the HCDF and 39 belonged to the HNCF. Compared with the HNCF, the IL-1ß, MCP-1, and TNF-α in the HCDF were significantly increased (P < .01). The Pearson correlation analysis showed that inflammatory factors were positively correlated with hemoglobin, and negatively correlated with MMSE. Serum inflammatory cytokines IL-1, MCP-1, and TNF-α were increased in HAPC, and HAPC exhibited cognitive dysfunction. Considering chronic hypoxia environment influences the change of the red blood cell metabolic and inflammatory factor, red blood cells and inflammatory factor in plateau is likely to be affected by patients with vascular lesions, increase cognitive impairment.


Assuntos
Altitude , Quimiocina CCL2 , Cognição , Interleucina-1beta , Policitemia , Fator de Necrose Tumoral alfa , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença da Altitude/sangue , Estudos de Casos e Controles , Quimiocina CCL2/sangue , Cognição/fisiologia , Disfunção Cognitiva/sangue , Disfunção Cognitiva/etiologia , Inflamação/sangue , Interleucina-1beta/sangue , Policitemia/sangue , Fator de Necrose Tumoral alfa/sangue , Idoso
2.
Biomed Tech (Berl) ; 65(2): 219-227, 2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-31527289

RESUMO

Coronary stents made of zinc (Zn)-0.8 copper (Cu) (in wt%) alloy were developed as biodegradable metal stents (Zn-Cu stents) in this study. The mechanical properties of the Zn-Cu stents and the possible gain effects were characterized by in vitro and in vivo experiments compared with 316L stainless steel stents (316L stents). Young's modulus of the as-extruded Zn-0.8Cu alloy and properties of the stents, including their intrinsic elastic recoil, stent trackability were evaluated compared with 316L stents. In vivo study was also conducted to evaluate restoration of pulsatility of vessel segment implanted stents. Both Zn-Cu stents and 316L stents have good acute lumen gain. By comparison, the advantages of Zn-Cu stents are as follows: (I) Zn-Cu stents have less intrinsic elastic recoil than 316L stents; (II) stent trackability indicates that Zn-Cu stents have a smaller push force when passing through curved blood vessels, which may cause less mechanical stimulation to blood vessels; (III) in vivo study suggests that Zn-Cu stents implantation better facilitates the recovery of vascular pulsatility.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Stents , Zinco/química , Módulo de Elasticidade , Aço Inoxidável
3.
Catheter Cardiovasc Interv ; 96(2): E119-E128, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31659805

RESUMO

OBJECTIVES: The aim of this study is to improve local-drug delivery efficiency and tissue absorption using the ultrasound (US)-responsible drug coating based on a newly developed US-controlled paclitaxel release balloon. BACKGROUND: Low availability of the drug coating remains a major concern of the current drug coated balloon (DCB). The goal of this study is to develop a method to use an US-responsible paclitaxel-loaded microcapsules (PM) as the main content of balloon drug coating to enhance bioavailability of DCB. METHODS: An US-controlled paclitaxel release balloon is designed and fabricated based on the US-responsible paclitaxel-loaded poly (lactic-co-glycolic acid) (PLGA) microcapsules. Rapid exchange percutaneous transluminal coronary angioplasty (PTCA) balloon catheters were coated with the PM. The deployment processes of the paclitaxel-loaded microcapsules coated balloons (PMCB) under US, PMCB without US and a homogenous matrix of paclitaxel and iopromide coated balloon (PICB) were then placed in healthy and stent implanted porcine coronary arteries. RESULTS: In vitro release assay demonstrated an ability of US (1 MHz, 1.22 W/cm2 , 1 minute) to affect the release kinetics of paclitaxel from PM by inducing a 76 ± 5.4% increase in the rate of release. The paclitaxel content in target vessels are 203 ± 37 µg/g for PMCB under US, 85 ± 23 µg/g for PMCB without US, and 107 ± 31 µg/g for PICB 1-hr post-surgery. The availability of the drug for the PMCB reaches 27% under US. CONCLUSIONS: The US-controlled paclitaxel release balloon significantly improved the drug content of the target vessels in the porcine model.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Vasos Coronários/metabolismo , Paclitaxel/administração & dosagem , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Ondas Ultrassônicas , Animais , Fármacos Cardiovasculares/química , Fármacos Cardiovasculares/farmacocinética , Preparações de Ação Retardada , Portadores de Fármacos , Liberação Controlada de Fármacos , Masculino , Paclitaxel/química , Paclitaxel/farmacocinética , Solubilidade , Sus scrofa
4.
Sci Rep ; 9(1): 18549, 2019 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811206

RESUMO

The Cordimax stent has proved non-inferior to the Cypher Select durable polymer sirolimus-eluting stent for the primary endpoint of angiographic in-stent late luminal loss and in-stent mean diameter stenosis at 9 months. The trial was designed to compare the efficacy and safety of the Cordimax stent with the Xience V stent in patients undergoing coronary revascularization. This randomized, multicenter trial enrolled 3697 patients treated with Cordimax stent (2460 patients) and Xience V stent (1237 patients). The primary efficacy endpoint was a target-lesion failure (TLF) at 1 year and the primary safety endpoint was a composite of death or myocardial infarction (MI) at 3 years. 3399 patients (91.9%) completed 3-year follow-up. At 1 year, the primary efficacy endpoint occurred in 86 (3.5%) patients in the Cordimax group versus 40 (3.2%) patients in the Xience V group (0.3% absolute risk difference, 95% CI -1.0-1.5%, Pnon-inferiority < 0.0001). At 3 years, the primary safety endpoint occurred in 39 (1.6%) patients in the Cordimax group versus 19 (1.5%) patients in the Xience V group (0.05% absolute risk difference, 95% CI -0.8-0.9%, Pnon-inferiority < 0.0001). The incidence of target lesion revascularization was low in Cordimax group compared with Xience V group (3.6% versus 5.1%, P = 0.03). There were no differences between Cordimax and Xience V in terms of Cardiac death (0.3% versus 0.4%, P = 0.70), myocardial infarction (1.2% versus 0.9%, P = 0.37), and the stent thrombosis (0.4% versus 0.6%, P = 0.61). In conclusion, safety and efficacy outcomes of Cordimax stent were non-inferior to the Xience V stent 3 years after stent implantation.


Assuntos
Estenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Implantes Absorvíveis/efeitos adversos , Assistência ao Convalescente , Idoso , Estenose Coronária/complicações , Estenose Coronária/mortalidade , Preparações de Ação Retardada/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Polímeros/química , Trombose/epidemiologia , Trombose/etiologia , Resultado do Tratamento
5.
Acta Biomater ; 97: 657-670, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31401346

RESUMO

In the present study, a novel biodegradable Zn-0.8Cu coronary artery stent was fabricated and implanted into porcine coronary arteries for up to 24 months. Micro-CT analysis showed that the implanted stent was able to maintain structural integrity after 6 months, while its disintegration occurred after 9 months of implantation. After 24 months of implantation, approximately 28 ±â€¯13 vol% of the stent remained. Optical coherence tomography and histological analysis showed that the endothelialization process could be completed within the first month after implantation, and no inflammation responses or thrombosis formation was observed within 24 months. Cross-section analysis indicated that the subsequent degradation products had been removed in the abluminal direction, guaranteeing that the strut could be replaced by normal tissue without the risk of contaminating the circulatory system, causing neither thrombosis nor inflammation response. The present work demonstrates that the Zn-0.8Cu stent has provided sufficient structural supporting and exhibited an appropriate degradation rate during 24 months of implantation without degradation product accumulation, thrombosis, or inflammation response. The results indicate that the Zn-0.8Cu coronary artery stent is promising for further clinical applications. STATEMENT OF SIGNIFICANCE: Although Zn and its alloys have been considered to be potential candidates of biodegradable metals for vascular stent use, by far, no Zn-based stent with appropriate medical device performance has been reported because of the low mechanical properties of zinc. The present work presents promising results of a Zn-Cu biodegradable vascular stent in porcine coronary arteries. The Zn-Cu stent fabricated in this work demonstrated adequate medical device performance both in vitro and in vivo and degraded at a proper rate without safety problems induced. Furthermore, large animal models have more cardiovascular similarities as humans. Results of this study may provide further information of the Zn-based stents for translational medicine research.


Assuntos
Implantes Absorvíveis , Vasos Coronários , Teste de Materiais , Stents , Tomografia de Coerência Óptica , Animais , Cobre/química , Cobre/metabolismo , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Suínos , Fatores de Tempo , Zinco/química , Zinco/metabolismo
6.
BMC Plant Biol ; 19(1): 37, 2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30669983

RESUMO

BACKGROUND: Short chain oxylipins in plants as the main volatile organic carbon have been speculated to playing an important role for plant innate immunity, however, not yet intensively studied and far away established as the fully recognized algae defense signals. RESULTS: The production of 1-octen-3-ol is self-amplified via the fatty acid-oxylipin metabolic cycle through positive feedback loop. Production of 1-octen-3-ol may act as a messenger that induces P. haitanensis to be in a "primed" state and ready for defense by upregulating the synthesis of methyl jasmonic acid, indole-3-acetic acid, and gibberellin A3. Production of these oxylipins also adjust the redox state in cells, resulting in host defense activation. CONCLUSIONS: We provide the first demonstration that 1-octen-3-ol from P. haitanensis, can act as a self-stimulating community messenger. The multiple effects of 1-octen-3-ol may explain why P. haitanensis, a very ancient lineage within plant kingdom, thrives in the niche of intertidal zones.


Assuntos
Octanóis/metabolismo , Oxilipinas/metabolismo , Rodófitas/metabolismo , Transdução de Sinais , Bactérias/metabolismo , Ácidos Graxos não Esterificados/metabolismo , Expressão Gênica , Metabolismo dos Lipídeos , Lipoxigenase/genética , Lipoxigenase/metabolismo , Oxirredução , Fosfolipases/metabolismo , Rodófitas/genética , Rodófitas/imunologia , Rodófitas/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...