Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 8(1): 1855, 2017 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-29187751

RESUMO

Metal nanoparticles prepared by exsolution at the surface of perovskite oxides have been recently shown to enable new dimensions in catalysis and energy conversion and storage technologies owing to their socketed, well-anchored structure. Here we show that contrary to general belief, exsolved particles do not necessarily re-dissolve back into the underlying perovskite upon oxidation. Instead, they may remain pinned to their initial locations, allowing one to subject them to further chemical transformations to alter their composition, structure and functionality dramatically, while preserving their initial spatial arrangement. We refer to this concept as chemistry at a point and illustrate it by tracking individual nanoparticles throughout various chemical transformations. We demonstrate its remarkable practical utility by preparing a nanostructured earth abundant metal catalyst which rivals platinum on a weight basis over hundreds of hours of operation. Our concept enables the design of compositionally diverse confined oxide particles with superior stability and catalytic reactivity.

2.
Microsc Microanal ; 22(5): 939-947, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27619633

RESUMO

The development of the helium ion microscope (HIM) enables the imaging of both hard, inorganic materials and soft, organic or biological materials. Advantages include outstanding topographical contrast, superior resolution down to <0.5 nm at high magnification, high depth of field, and no need for conductive coatings. The instrument relies on helium atom adsorption and ionization at a cryogenically cooled tip that is atomically sharp. Under ideal conditions this arrangement provides a beam of ions that is stable for days to weeks, with beam currents in the order of picoamperes. Over time, however, this stability is lost as gaseous contamination builds up in the source region, leading to adsorbed atoms of species other than helium, which ultimately results in beam current fluctuations. This manifests itself as horizontal stripe artifacts in HIM images. We investigate post-processing methods to remove these artifacts from HIM images, such as median filtering, Gaussian blurring, fast Fourier transforms, and principal component analysis. We arrive at a simple method for completely removing beam current fluctuation effects from HIM images while maintaining the full integrity of the information within the image.

3.
Nanotechnology ; 24(33): 335706, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-23892516

RESUMO

The invention of the atomic force microscope led directly to the possibility of carrying out nanomechanical tests with forces below the nanonewton and the ability to test nanomaterials and single molecules. As a result there is a pressing need for accurate and traceable force calibration of AFM measurements that is not satisfactorily met by existing calibration methods. Here we present a force reference device that makes it possible to calibrate the normal stiffness of typical AFM microcantilevers down to 90 pN nm(-1) with very high accuracy and repeatability and describe how it can be calibrated traceably to the International System of Units via the ampere and the metre, avoiding in that way the difficulties associated with traceability to the SI kilogram. We estimate the total uncertainty associated with cantilever calibration including traceability to be better than 3.5%, thus still offering room for future improvement.

4.
Nanotechnology ; 14(12): 1279-88, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21444981

RESUMO

Calibration of atomic force microscope (AFM) cantilevers is necessary for the measurement of nanonewton and piconewton forces, which are critical to analytical applications of AFM in the analysis of polymer surfaces, biological structures and organic molecules at nanoscale lateral resolution. We have developed a compact and easy-to-use reference artefact for this calibration, using a method that allows traceability to the SI (Système International). Traceability is crucial to ensure that force measurements by AFM are comparable to those made by optical tweezers and other methods. The new non-contact calibration method measures the spring constant of these artefacts, by a combination of electrical measurements and Doppler velocimetry. The device was fabricated by silicon surface micromachining. The device allows AFM cantilevers to be calibrated quite easily by the 'cantilever-on-reference' method, with our reference device having a spring constant uncertainty of around ± 5% at one standard deviation. A simple substitution of the analogue velocimeter used in this work with a digital model should reduce this uncertainty to around ± 2%. Both are significant improvements on current practice, and allow traceability to the SI for the first time at these nanonewton levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...