Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Can Geriatr J ; 23(4): 277-282, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33282047

RESUMO

BACKGROUND: Delirium is characterized by fluctuating attention or arousal, with high prevalence in the orthopaedic ward. Our aim was to: 1) establish the prevalence of delirium on an orthopaedic ward, and 2) compare delirium prevalence using a single geriatrician assessment vs. multiple 3D-CAM (3-Minute Diagnostic Interview for Confusion Assessment Method) assessments during the day. We hypothesized that multiple assessments would increase the detection rate due to the fluctuating nature of delirium. METHODS: Comparative study conducted at an academic hospital in Hamilton, Ontario. Participants included patients 65 years and older admitted to the orthopaedic ward (n=55). After a geriatrician made the first assessment of delirium by 3D-CAM on each patient, teams with specialized geriatrics training re-assessed participants up to four times. Delirium rates based on first assessment were compared to cumulative end-of-day rates to determine if detection increased with multiple assessments. RESULTS: The prevalence of delirium was 30.9% (17 participants) using multiple assessments. Of these cases, 13 (76.4%) were detected in the initial geriatrician assessment. In patients with hip fractures, 70.6% (12 of 17) were identified as delirious by multiple assessments. CONCLUSION: As symptoms fluctuate, multiple daily CAM assessments may increase the identification of delirium in orthopaedic inpatients.

2.
Clin Exp Obstet Gynecol ; 38(3): 247-50, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21995157

RESUMO

This study examined the factors that influence the optimal dose of epidural anesthesia (EA), its effect on labor duration, and the frequency of vacuum and forceps administration at the end of delivery. The study group included 100 women who underwent vaginal delivery with EA with administration of 0.125% bupivacaine. A control group included 100 vaginally delivered women, without EA administration. In both groups delivery was stimulated by syntocinon. The level of labor pain influenced the optimal bolus dose of EA more than the body mass. However, the maintenance dose was influenced by both of these factors equally. Labor in the study group was somewhat shorter. In the group with EA the percentage of forceps and vacuum extractor application was twice that in the control group. There was no difference in average value of 5-minute Apgar scor in newborns.


Assuntos
Anestesia Epidural , Anestésicos Locais/administração & dosagem , Trabalho de Parto , Forceps Obstétrico/estatística & dados numéricos , Vácuo-Extração/estatística & dados numéricos , Adulto , Índice de Massa Corporal , Bupivacaína/administração & dosagem , Estudos de Casos e Controles , Relação Dose-Resposta a Droga , Feminino , Humanos , Dor do Parto/tratamento farmacológico , Medição da Dor , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...