Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 29(4): 559-64, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16565794

RESUMO

The purpose of the study was to assess the clinical safety and efficacy of the "Recovery(TM)" (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a "Recovery(TM)" IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. "Recovery" filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean: 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following "Recovery" filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.


Assuntos
Embolia Pulmonar/terapia , Tromboembolia/terapia , Filtros de Veia Cava , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Tromboembolia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
Obes Surg ; 12(1): 121-3, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11868288

RESUMO

BACKGROUND: Port site herniation is an uncommon event that usually occurs as a result of incomplete fascial closure. This allows the omentum or viscera to herniate through the incompletely closed defect. However, in laparoscopic surgery for morbid obesity, the omentum and viscera can herniate through the thick preperitoneal space even with a complete closure of the fascia. CASE REPORT: A 19-year-old female with BMI 55 underwent uneventful long limb laparoscopic Roux-en-Y gastric bypass. On postoperative day 1 the patient had limited pain, was ambulating well, and was tolerating slps of liquids. A limited upper GI series performed on postoperative day 2 revealed no leak or obstruction. Several hours later the patient developed abdominal pain associated with nausea, which progressed to vomiting. CT of the abdomen suggested a port site herniation into the left subcostal port. The cause of the obstruction appeared to be herniation through the left subcostal port site. At laparotomy, a segment of bowel just distal to the anastomosis was found herniated through the port site. The Richter's hernia was reduced. Careful inspection of the fascia revealed a complete fascial closure, with the strangulated portion of the bowel incarcerated in the preperitoneal space. Following repair of the preperitoneal defect, her subsequent recovery was unremarkable. CONCLUSION: Laparoscopic surgery for morbid obesity presents the possibility for preperitoneal herniation. Closure, using a fascial closure device, under laparoscopic control, may offer a solution by closing both the fascia and peritoneum all at once.


Assuntos
Derivação Gástrica/efeitos adversos , Enteropatias/etiologia , Laparoscopia/efeitos adversos , Adulto , Feminino , Derivação Gástrica/métodos , Hérnia , Humanos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...