Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PDA J Pharm Sci Technol ; 75(3): 258-272, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33199514

RESUMO

This study investigated the liquid leakage mechanism through microchannels in a flexible single-use packaging system composed of multilayer plastic film. Based on this study, a relationship between the maximum allowable leakage limit (MALL) and the loss of package integrity can be established under different use-case conditions. The MALL is defined as the greatest leak size that does not pose any risk to the product. A specifically designed liquid leak test was used to determine the leakage time, i.e., the time it takes for a package to show leakage. As a result, this method was able to determine the leak size for which no liquid leakage is observed after 30 days. This leak size varied between 2 µm and 10 µm and can be considered the MALL for liquid egress under different use-case conditions. This article also compared the MALL results of this liquid leak test with those of the microbial ingress test, showing a direct correlation between both tests. As test samples, an ethylene vinyl acetate multilayer film (300 µm thick) and a polyethylene multilayer film (400 µm thick) were cut into 50 mm patches. Before the patches were assembled in a filter holder to form a leak-tight seal, artificial leaks in sizes of 2 -25 µm were laser drilled into the center of each patch. The test units were filled aseptically with culture media and mounted vertically on the test setup. Various pressures were applied to each test unit to simulate the constraints that single-use systems may be subject to under real-world conditions. To detect the exact leakage time, electric circuits with timers were attached below each film patch. Microscopic investigations, including light microscopy and computed tomography, were used to interpret and understand the physics and geometries of the microchannels to explain any deviation from the expected results.


Assuntos
Embalagem de Medicamentos , Embalagem de Produtos , Lasers , Plásticos , Polietileno
2.
PDA J Pharm Sci Technol ; 73(5): 459-469, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31004038

RESUMO

An aerosol microbial ingress test was specifically designed and used to create a predictive model in order to determine the maximum allowable leakage limit (MALL) of single-use systems (SUSs). The MALL is defined as the greatest leak size that does not pose any risk to the product. The procedure involved taking test samples of film material from single-use bags. As test samples, an ethylene vinyl acetate multilayer film (300 µm thick) and a polyethylene multilayer film (400 µm thick) were cut into 50 mm patches. Artificial defects of 1-100 µm were laser-drilled in the middle of each film patch. The patch was assembled on a holder and properly sealed. The test units were filled aseptically with culture media and placed inside an aerosol chamber. Various pressures were applied to the test unit to simulate the constraints that single-use systems may be subject to under real-world conditions. After an aerosolization cycle with spores of Bacillus atrophaeus, a minimum concentration of 106 CFU/cm2 was reached on the film surface. The test units were incubated for 14 days at 30°C-35°C and visually inspected for bacterial ingress. Thirty samples per defect size were tested. Logistic regression was used to indicate the MALL for a single-use system according to the required risk level. With this method, the probability of the occurrence or absence of ingress for a specific defect size was reported according to the experimental data. In addition to physical parameters, such as the pressure applied and the film material, the effect of the probabilistic nature of the microorganisms in determining the MALL is considered. Although finding an experimental model to predict the MALL for real-life process conditions was the ultimate objective, this paper also presents the microbial ingress test data obtained so far for two extreme conditions. Potential constraints, such as vibration, shock, acceleration, liquid movement, and pressure differentials, observed during normal usage were simulated using two extreme differential pressures, 0 mbar and 300 mbar. The estimated MALL for typical use-case conditions are 10-20 µm for storage applications and 2-10 µm for shipping conditions. The microbial integrity test method used in this article was able to detect bacterial ingress down to 3 µm defect size.LAY ABSTRACT: As use of single-use systems (SUSs) is increasingly expanding into all process steps of commercial manufacturing, integrity failure can significantly impact drug safety, availability, and costs. Consequently, growing industry scrutiny on single-use system integrity (SUSI) is raising the need to develop good science behind reliable determinations of liquid leakage and microbial ingress as well as the appropriate physical integrity testing technologies. In the current study, microbial ingress testing by the aerosol method is used to determine the maximum allowable leakage limit (MALL) for SUSs. To define the MALL, it is generally assumed that a system or product will not show any microbial ingress or leakage at a certain defect size. Statistical analysis of the experimental data in this study indicated the MALL with probability at a certain defect size for each system. As a result, the method studied provides a more accurate way of predicting ingress and increasing safety down the line for drug manufacturers and patients alike.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Embalagem de Medicamentos , Preparações Farmacêuticas/normas , Bacillus/isolamento & purificação , Polietileno/química , Polivinil/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...