1.
J Nucl Cardiol ; 8(5): 548-54, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11593218

RESUMO

BACKGROUND: The objectives of this study were 2-fold: (1) to determine the tolerance of adenosine perfusion tomography with the use of an abbreviated (3-minute) infusion in comparison to the standard (6-minute) infusion, and (2) to assess the relative diagnostic accuracy of a 3-minute adenosine infusion in patients referred for arteriography. An abbreviated adenosine infusion may decrease the frequency and duration of side effects and be a more cost-effective alternative. METHODS AND RESULTS: We prospectively randomized 599 patients undergoing adenosine myocardial perfusion tomography to either a 3-minute or 6-minute adenosine infusion at 140 microg/kg per minute. Among the 599 enrolled patients, 142 subsequently underwent coronary angiography. Patients randomized to the 3-minute adenosine infusion tolerated the procedure better than those randomized to the standard infusion (P <.01). Flushing, headache, neck pain, and atrioventricular block were all significantly less frequent (P <.01) with the abbreviated infusion. Moreover, patients receiving the abbreviated infusion had less hypotension and tachycardia (P <.05). The sensitivity of the test for detection of coronary artery disease was 88% for both the 3- and 6-minute infusions. In patients with abnormal scan results, perfusion defect size was slightly larger in those receiving a 6-minute infusion versus those receiving a 3-minute infusion (P =.05). CONCLUSIONS: An abbreviated 3-minute adenosine infusion, in combination with perfusion tomography, has similar sensitivity for detection of coronary artery disease and is better tolerated than the standard 6-minute infusion.


Assuntos
Adenosina , Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adenosina/efeitos adversos , Adulto , Idoso , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo
2.
Circulation ; 102(4): 438-44, 2000 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-10908217

RESUMO

BACKGROUND: We investigated the hemodynamic and coronary vasodilatory effects of CGS-21680, a potent selective adenosine A(2A) agonist, as well as its potential use as a new stress modality in combination with perfusion scintigraphy. METHODS AND RESULTS: A stenosis of the left anterior descending coronary artery (LAD) was produced in dogs to reduce the reactive hyperemic response to <20%. Adenosine and CGS-21680 were then separately infused to maximize left circumflex coronary artery (LCx) flow velocity. (201)Tl (0.5 mCi) and (99m)Tc-sestamibi (5 mCi) were injected at the maximal dose of CGS-21680. Heart rate decreased with adenosine but increased during CGS-21680 infusion (P<0.005). The decrease in systolic blood pressure was more prominent with adenosine than with CGS-21680 (P<0.005). In the control LCx zone, maximal myocardial blood flow (MBF) (measured by radioactive microspheres) increased 3.1-fold during adenosine infusion (P<0.005) and 3.8-fold during CGS-21680 infusion (P<0.005). In the stenotic LAD zone, MBF did not change significantly. During adenosine and CGS-21680 infusion, stenosis/control zone MBF ratios were comparable (0.32+/-0.11 versus 0.27+/-0.10, P=NS), and transmural (201)Tl and (99m)Tc-sestamibi count-activity ratios (0.48+/-0.11 and 0.51+/-0.09, respectively) were also comparable (P=NS). Myocardial scintigraphy uncovered perfusion defects in all dogs. CONCLUSIONS: CGS-21680 elicits coronary vasodilation comparable to that of adenosine and produces profound heterogeneity of MBF and of (201)Tl and (99m)Tc-sestamibi myocardial uptake, rendering it a promising agent for pharmacological myocardial perfusion imaging.


Assuntos
Adenosina/análogos & derivados , Anti-Hipertensivos/farmacologia , Circulação Coronária/efeitos dos fármacos , Contração Miocárdica/efeitos dos fármacos , Fenetilaminas/farmacologia , Compostos Radiofarmacêuticos/farmacologia , Tecnécio Tc 99m Sestamibi/farmacologia , Tálio/farmacologia , Adenosina/farmacologia , Animais , Cães , Agonistas do Receptor Purinérgico P1 , Vasodilatação/efeitos dos fármacos
3.
J Am Coll Cardiol ; 35(5): 1152-61, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10758955

RESUMO

OBJECTIVES: The study assessed whether end-diastolic wall thickness (EDWT), measured with echocardiography, is an important marker of myocardial viability in patients with suspected myocardial hibernation, and it compared this index to currently established diagnostic modalities of dobutamine stress echocardiography (DSE) and rest-redistribution thallium-201 (T1-201) scintigraphy. BACKGROUND: Because myocardial necrosis is associated with myocardial thinning, preserved EDWT may provide a simple index of myocardial viability that is readily available from the resting echocardiogram. METHODS: Accordingly, 45 patients with stable coronary artery disease and ventricular dysfunction underwent rest 2D echocardiograms, DSE and rest-redistribution T1-201 tomography before revascularization and a repeat resting echocardiogram > or =2 months later. RESULTS: Global wall motion score index decreased from 2.38 +/- 0.73 to 1.94 +/- 0.82 after revascularization (p < 0.001). Thirty-eight percent of severely dysfunctional segments recovered resting function. Compared to segments without recovery of resting function, those with recovery had greater EDWT (0.94 +/- 0.18 cm vs. 0.67 +/- 0.22 cm, p < or = 0.0001) and a higher T1-201 uptake (78 +/- 13% vs. 59 +/- 21%; p < 0.0001). An EDWT >0.6 cm had a sensitivity of 94% and specificity of 48% for recovery of function. Similarly, a T1-201 maximal uptake of > or =60% had a sensitivity of 91% and specificity of 50%. Receiver operating characteristic curves for prediction of recovery of regional and global function were similar for EDWT and maximum T1-201 uptake. Combination of EDWT and any contractile reserve during DSE for recovery of regional function improved the specificity to 77% without a significant loss in sensitivity (88%). CONCLUSIONS: End-diastolic wall thickness is an important marker of myocardial viability in patients with suspected hibernation, and it can predict recovery of function similar to T1-201 scintigraphy. Importantly, a simple measurement of EDWT < or =0.6 cm virtually excludes the potential for recovery of function and is a valuable adjunct to DSE in the assessment of myocardial viability.


Assuntos
Cardiotônicos , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico , Dobutamina , Ecocardiografia/normas , Teste de Esforço/normas , Miocárdio Atordoado/etiologia , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/normas , Idoso , Doença das Coronárias/fisiopatologia , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Volume Sistólico
4.
Rev Port Cardiol ; 19 Suppl 1: I39-46, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10750438

RESUMO

Left ventricular (LV) function and volumes have major diagnostic and prognostic importance in patients with heart diseases. Those measurements are most commonly obtained with echocardiographic techniques. Recently, with the use of electrocardiographic gating during the acquisition of myocardial perfusion scintigraphy, it has become possible to simultaneously assess LV perfusion, function and volumes. Both technetium-99m labeled agents and thallium-201, the most commonly used tracers for perfusion scintigraphy, can be used for gated perfusion purposes. Many authors compared gated perfusion images to echocardiography, in regard to LV global and segmental wall motion as well as volumes. We performed gated single photon emission computed tomography (SPECT) and echocardiography in 109 consecutive patients (53 male, 56 female, mean age 63 +/- 14 years) within 15 days of each other. Gated tomographic data, including LV volumes, LV ejection fraction and segmental wall motion, were processed using an automatic algorithm whereas echocardiography used standard techniques. To obtain interobserver and intraobserver variability of regional wall motion, we randomly re-analyzed 34 of the 109 gated SPECT studies. The correlations between gated tomography and echocardiography with respect to end-diastolic volume, end-systolic volume and left ventricular ejection fraction were good to excellent (all p < 0.001, r values > or = 0.68) regardless of the use of post-stress or rest/redistribution images, thallium-201 or technetium-99m tracers. The agreement between both techniques, regarding segmental wall motion analysis were also good. Intraobserver and interobserver variability for regional wall motion were good to excellent, with an agreement of 90% and 88%, respectively. Other authors also had similar results in different studies with different populations, tracers, imaging acquisition and processing protocols. Thus, quantitative gated SPECT, using a variety of protocols and with either Tl-201 or Tc-99m tracers, has a good correlation with echocardiography for the measurements of absolute LV volumes and LV global and regional function. This technique is highly reproducible and can be used clinically for those measurements, with the additional advantage that the ventricular performance parameters are obtained from the perfusion images. Furthermore, contrary to echocardiographic techniques used to assess LV volumes and LV function, which are quite labor intensive and more observer-dependent, the gated SPECT technique is nearly totally automatic, and highly reproducible.


Assuntos
Ecocardiografia , Imagem do Acúmulo Cardíaco de Comporta , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Idoso , Ecocardiografia/estatística & dados numéricos , Feminino , Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
5.
J Nucl Med ; 40(11): 1857-65, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10565781

RESUMO

UNLABELLED: The purpose of this study was to evaluate left ventricular volumes and function by gated SPECT using different tracers and protocols in comparison with quantitative echocardiography. Gated myocardial perfusion scintigraphy permits simultaneous assessment of left ventricular perfusion, function and volumes. Information is scanty regarding the accuracy of absolute left ventricular volumes measurements by this technique. METHODS: We performed gated SPECT and echocardiography within 15 d of each other in 109 consecutive patients (53 men, 56 women; mean age 63 +/- 14 y). Gated tomographic data, including left ventricular volumes and ejection fraction, were processed using an automatic algorithm, whereas echocardiography used standard techniques. RESULTS: The correlations between gated tomography and echocardiography with respect to end-diastolic volume, end-systolic volume and left ventricular ejection fraction were good to excellent (all P < 0.001, r values > or = 0.68), regardless of the use of poststress or rest/redistribution images, 201Tl or 99mTc tracers. End-systolic volume was similar with gated tomography and echocardiography (P = ns), but end-diastolic volume and left ventricular ejection fraction were significantly higher with echocardiography (P < or = 0.05). CONCLUSION: Quantitative gated tomography, using either 201Tl or 99mTc tracers, has a good correlation with echocardiography for the assessment of left ventricular volumes and ejection fraction. These results support the clinical use of this new technique.


Assuntos
Ecocardiografia , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
J Nucl Cardiol ; 6(4): 412-7, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10461608

RESUMO

BACKGROUND: We compared estimates of left ventricular ejection fraction (LVEF) assessed by gated single photon emission computed tomography (SPECT), using both technetium-99m sestamibi and thallium-201, with those obtained by first-pass radionuclide angiography (FPRNA) in patients with a broad spectrum of LVEF and perfusion abnormalities. METHODS: Sixty-three patients were randomly selected to undergo a dual isotope gated SPECT study (rest Tl-201 followed by adenosine Tc-99m sestamibi scintigraphy). Studies were processed by use of the Cedars quantitative gated SPECT software. FPRNA was acquired during an intravenous bolus injection of Tc-99m sestamibi and processed with a commercially available software. RESULTS: The estimates of LVEF were similar (P = NS) with Tl-201 gated SPECT (54% +/- 15%), Tc-99m gated SPECT (54% +/- 16%), and FPRNA (54% +/- 12%). There was an excellent correlation between Tc-99m and Tl-201 gated SPECT (Pearson's r = 0.92, P < .0001). There were also good linear correlations between Tc-99m sestamibi gated SPECT and FPRNA (Pearson's r = 0.85, P < .0001), as well as between Tl-201 gated SPECT and FPRNA (Pearson's r = 0.84, P < .0001). In the 16 patients with LVEF < 50%, Tc-99m sestamibi gated SPECT and FPRNA (Pearson's r = 0.84, P < .0001) and Tl-201 gated SPECT and FPRNA (Pearson's r = 0.92, P < .0001) correlated well. CONCLUSION: LVEF can be accurately assessed by gated SPECT with either Tc-99m sestamibi or Tl-201 in properly selected patients with normal or depressed left ventricular function.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Volume Sistólico/fisiologia , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda/fisiologia , Ventriculografia de Primeira Passagem , Adenosina , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...