Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 73: 44-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23274215

RESUMO

A feasibility study regarding the production of radioactive carbon black and nanotubes has been performed by proton beam irradiation. Experimental and theoretical excitation functions of the nuclear reaction (nat)C(p,x)(7)Be in the proton energy range 24-38 MeV are reported, with an acceptable agreement. We have demonstrated that sufficient activities of (7)Be radioisotope can be produced in carbon black and nanotube that would facilitate studies of their possible impact on human and environment.


Assuntos
Berílio/química , Radioisótopos de Carbono/química , Nanotubos de Carbono/química , Compostos Radiofarmacêuticos/química , Fuligem/química , Ciclotrons , Estudos de Viabilidade , Humanos , Nanotecnologia
2.
Arch Toxicol ; 85(7): 751-73, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21479952

RESUMO

We present in this article an outline of some cyclotron-based irradiation techniques that can be used to directly radiolabel industrially manufactured nanoparticles, as well as two techniques for synthesis of labelled nanoparticles using cyclotron-generated radioactive precursor materials. These radiolabelled nanoparticles are suitable for a range of different in vitro and in vivo tracing studies of relevance to the field of nanotoxicology. A basic overview is given of the relevant physics of nuclear reactions regarding both ion-beam and neutron production of radioisotopes. The various issues that determine the practicality and usefulness of the different methods are discussed, including radioisotope yield, nuclear reaction kinetics, radiation and thermal damage, and radiolabel stability. Experimental details are presented regarding several techniques applied in our laboratories, including direct light-ion activation of dry nanoparticle samples, neutron activation of nanoparticles and suspensions using an ion-beam driven activator, spark-ignition generation of nanoparticle aerosols using activated electrode materials, and radiochemical synthesis of nanoparticles using cyclotron-produced isotopes. The application of these techniques is illustrated through short descriptions of some selected results thus far achieved. It is shown that these cyclotron-based methods offer a very useful range of options for nanoparticle radiolabelling despite some experimental difficulties associated with their application. For direct nanoparticle radiolabelling, if care is taken in choosing the experimental conditions applied, useful activity levels can be achieved in a wide range of nanoparticle types, without causing substantial thermal or radiation damage to the nanoparticle structure. Nanoparticle synthesis using radioactive precursors presents a different set of issues and offers a complementary and equally valid approach when laboratory generation of the nanoparticles is acceptable for the proposed studies, and where an appropriate radiolabel can be incorporated into the nanoparticles during synthesis.


Assuntos
Marcação por Isótopo/métodos , Nanopartículas/química , Nanopartículas/efeitos da radiação , Radioisótopos/química , Ciclotrons , Nanopartículas Metálicas/química , Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/toxicidade , Nanopartículas/toxicidade , Traçadores Radioativos , Termodinâmica
3.
J Fluoresc ; 17(1): 29-36, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17165123

RESUMO

This paper deals with the photo-induced fluorimetric determination of the herbicide Fluometuron with the aid of a continuous-flow assembly of the emergent and new methodology known as Multicommutation which was provided with an on-line photoreactor. Maximum fluorescence intensity was observed at basic pH solutions, 1x 10(-4) mol l(-1) NaOH, after 1.4 min of irradiation and being the maximum at lambda(exc) 247.0 nm and lambda(em) 325.0 nm. The influence of different experimental parameters either chemical (pH, surfactants presence, solvent polarity and temperature) or hydrodynamic (time of photo-degradation, size and number of different segments and flow-rate) was tested. The linear dynamic range was from 0.01 to 4.0 mg l(-1) of Fluometuron; the inter-day reproducibility (as R.S.D.) of the slope was 0.001% and 1.7% from the peaks intra-day reproducibility. A large series of potential interferents was studied and finally the method was applied to human urine, soil, formulation and water samples.


Assuntos
Fluorescência , Herbicidas/análise , Compostos de Metilureia/análise , Automação , Herbicidas/química , Concentração de Íons de Hidrogênio , Compostos de Metilureia/química , Estrutura Molecular , Peso Molecular , Fotólise , Sensibilidade e Especificidade , Espectrometria de Fluorescência , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...