Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Res Int ; 169: 112846, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37254420

RESUMO

Heat and acid-induced milk gels do not melt or flow upon heating and thus show great potential as a dairy-based protein source for cooking, e.g. for stews. Understanding how processing, e.g. acidification, affects the cooking behavior of these gels is therefore of great industrial interest. The cooking integrity of gels produced by rapidly acidifying milk using citric acid at temperatures of 60, 75, and 90 °C, was determined by analyzing composition, texture, and spatial water distribution before and after cooking. Increasing the acidification temperature from 60 to75 °C resulted in a significant reduction of yield, due to decreased moisture content of the gels. With increasing content of solids, the gels grew harder and denser, as observed by texture profile analysis and low-field Nuclear Magnetic Resonance. Upon cooking the 60 °C gel lost a significant amount of moisture, due to the contraction of the porous protein network. The more compact gels, prepared at 75 and 90 °C, did not lose mass indicating good cooking integrity, i.e. a gel that keeps its structure during cooking. Acidification temperature thus greatly influenced cooking integrity. The effect was mainly ascribed to the density of the gel texture, a result of the speed of protein aggregation and calcium recovery.


Assuntos
Temperatura Alta , Leite , Animais , Temperatura , Leite/química , Culinária , Géis/química
2.
Food Res Int ; 158: 111554, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35840247

RESUMO

There is an increasing demand to produce high-quality plant-based meat analogs rich in tenderness and juiciness, presenting a significant challenge in creating oil-containing fibrous structures. A novel oil addition approach was developed by adding oil-in-water (O/W) emulsion during high-moisture extrusion processing. The current study investigated the effect of oil content using O/W emulsion on high-moisture extrudates prepared from soy protein isolate (SPI) and wheat gluten (WG) (SPI-WG). The oil content in fibrous SPI-WG extrudate could be up to 8.0% using O/W emulsion, whereas only 4.0% was possible by direct oil addition. O/W emulsion addition significantly decreased the extrusion response parameters of die pressure and specific mechanical energy. Confocal laser scanning microscopy indicated that oil was distributed to small droplets (0.5-15.0 µm) within the protein matrix in SPI-WG extrudates. Oil-free SPI-WG extrudate presented a close-meshed protein network. In contrast, higher oil contents led to more porous structures in SPI-WG extrudates with 3.0-8.0% oil. O/W emulsion addition reduced the rubber-like texture and rheological properties of SPI-WG extrudates, which improved the textural attributes (e.g., chewiness), making them similar to those of cooked chicken breast. In addition, the mobility of water and oil protons increased with increasing oil contents in SPI-WG extrudates, indicating the water and oil binding properties were reduced. Overall, this study demonstrated the potential of using O/W emulsions to promote fibrous structures of high-moisture extrudates.


Assuntos
Glutens , Proteínas de Soja , Emulsões/química , Glutens/química , Reologia , Proteínas de Soja/química , Água/química
3.
Molecules ; 26(8)2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33924497

RESUMO

Cyclodextrins (CDs) are cyclic oligosaccharides that have found widespread application in numerous fields. CDs have revealed a number of various health benefits, making them potentially useful food supplements and nutraceuticals. In this study, the impact of α-, ß-, and γ-CD at different concentrations (up to 8% of the flour weight) on the wheat dough and bread properties were investigated. The impact on dough properties was assessed by alveograph analysis, and it was found that especially ß-CD affected the viscoelastic properties. This behavior correlates well with a direct interaction of the CDs with the proteins of the gluten network. The impact on bread volume and bread staling was also assessed. The bread volume was in general not significantly affected by the addition of up to 4% CD, except for 4% α-CD, which slightly increased the bread volume. Larger concentrations of CDs lead to decreasing bread volumes. Bread staling was investigated by texture analysis and low field nuclear magnetic resonance spectroscopy (LF-NMR) measurements, and no effect of the addition of CDs on the staling was observed. Up to 4% CD can, therefore, be added to wheat bread with only minor effects on the dough and bread properties.


Assuntos
Pão , Triticum , gama-Ciclodextrinas/química , Ciclodextrinas/química , Espectroscopia de Ressonância Magnética
4.
Foods ; 9(3)2020 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-32138384

RESUMO

Wheat flour is widely used on an industrial scale in baked goods, pasta, food concentrates, and confectionaries. Ash content and moisture can serve as important indicators of the wheat flour's quality and use, but the routinely applied assessment methods are laborious. Partial least squares regression models, obtained using Raman spectra of flour samples and the results of reference gravimetric analysis, allow for fast and reliable determination of ash and moisture in wheat flour, with relative standard errors of prediction of the order of 2%. Analogous calibration models that enable quantification of carbon, oxygen, sulfur, and nitrogen, and hence protein, in the analyzed flours, with relative standard errors of prediction equal to 0.1, 0.3, 3.3, and 1.4%, respectively, were built combining the results of elemental analysis and Raman spectra.

5.
Polymers (Basel) ; 11(4)2019 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-31010147

RESUMO

An easy-to-prepare pH sensor based on electrochemically obtained polypyrrole doped with methyl orange ions is described. It enables the determination of a pH value in the 3-13 range for volumes below 1 µL. In a wide pH range, resonance and pre-resonance methyl orange Raman spectra, excited with the 514.5 nm line of an Ar+ laser, changed noticeably in function of H+ concentration. Two types of measurements were performed. In the first case, Raman spectra of the analyzed solutions were collected for samples placed on the sensor surface using a confocal microscope equipped with a 10x objective. Next, measurements were conducted for the same samples without the sensor. On the basis of these spectra, partial least-squares models were elaborated and validated. Relative standard errors of prediction for calibration, validation, and test samples were found to be in the 3.7%-3.9% range. An analogous model build using spectra registered without the sensor was characterized by slightly worse parameters.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 196: 413-417, 2018 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-29499570

RESUMO

FT-Raman quantitative analysis of nutritional parameters of yoghurts was performed with the help of partial least squares models. The relative standard errors of prediction for fat, lactose and protein determination in the quantified commercial samples equalled to 3.9, 3.2 and 3.6%, respectively. Models based on attenuated total reflectance spectra of the liquid yoghurt samples and of dried yoghurt films collected with the single reflection diamond accessory showed relative standard errors of prediction values of 1.6-5.0% and 2.7-5.2%, respectively, for the analysed components. Despite a relatively low signal-to-noise ratio in the obtained spectra, Raman spectroscopy, combined with chemometrics, constitutes a fast and powerful tool for macronutrients quantification in yoghurts. Errors received for attenuated total reflectance method were found to be relatively higher than those for Raman spectroscopy due to inhomogeneity of the analysed samples.


Assuntos
Análise Espectral Raman/métodos , Iogurte/análise , Análise Multivariada , Análise de Componente Principal , Razão Sinal-Ruído
7.
Talanta ; 178: 294-298, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136825

RESUMO

Pasta aside from bread is the most consumed cereal-based product in the world. Its taste and cooking ease makes it the basis of many cuisines. The pasta dough formed by mixing flour and water is extruded through an extrusion die to mould the appropriate pasta form and is dried to obtain a stable product. The concentration of moisture in the pasta dough is a one of key parameters determining the final quality of the product. Monitoring the moisture content of pasta after extrusion is also critically important. It enables a selection of suitable drying conditions that ensure the appropriate parameters of pasta, such as texture, color and taste, are met. A method for the quantitative determination of moisture content in pasta dough and in pasta based on the partial least squares treatment of infrared spectra registered using a single-reflection attenuated total reflectance diamond accessory is described. Results of a similar quality were found using models derived from near infrared spectra obtained in a diffuse reflectance mode and slightly worse based on Raman spectra. Relative standard errors of prediction calculated for moisture quantification by ATR/NIR/Raman techniques amounted to 2.54/3.16/5.56% and 2.15/3.32/5.67%, for calibration and validation sets, respectively. The proposed procedures can be used for fast and efficient pasta moisture quantification and may replace the current, more laborious methods used.


Assuntos
Farinha/análise , Espectroscopia de Infravermelho com Transformada de Fourier , Vibração , Água/análise , Culinária
8.
Talanta ; 161: 655-659, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27769461

RESUMO

Diffuse reflectance Fourier transform infrared spectroscopy (DRIFTS) is a fast, reliable and cost effective analytical method, requiring minimal or no sample preparation. It is commonly used in the course of qualitative and quantitative analysis of pharmaceutical ingredients and food. We demonstrate that simpler and cheaper specular reflectance (SR) accessory working in a DRIFTS like mode (SR-DL) can be an alternative for DIRFTS attachment. An application of a modified SR accessory for quantitative analysis of solids samples is presented. As a case study the concentration of cinnarizine in commercial tablets has been determined from DRIFTS and SR-DL infrared (IR) and near-infrared (NIR) spectra recorded using DTGS (deuterated triglicine sulphate) detector in the IR and NIR regions and InGaAs (indium-gallium arsenide) detector in the NIR range. Based on these spectra Partial Least Squares (PLS) models were constructed and relative standard errors of prediction (RSEP) were calculated for the calibration, validation and analysed data sets. They amounted to 2.4-2.5%, 2.1-2.7% and 2.0-2.6% for the DRIFTS attachment while 2.1-2.2%, 2.0-2.3% and 1.9-2.6%, respectively, for the modified SR accessory. Obtained error values indicate that modified SR accessory can be effectively used for quantification of solid pharmaceutical samples in the mid- and near-infrared regions.


Assuntos
Cinarizina/análise , Comprimidos/análise , Análise dos Mínimos Quadrados , Espectrofotometria Infravermelho , Espectroscopia de Infravermelho com Transformada de Fourier , Espectroscopia de Luz Próxima ao Infravermelho
9.
Food Chem ; 211: 560-3, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27283667

RESUMO

A procedure for the quantitative determination of gluten in wheat flour based on partial least squares (PLS) treatment of FT-Raman data is described. Results of similar quality were found using a PLS model derived from NIR (near infrared) spectra obtained in DRIFTS (diffuse reflectance infrared Fourier transform spectroscopy) mode and of slightly worse quality from the model constructed based on IR (infrared) spectra registered using a single reflection ATR (attenuated total reflection) diamond accessory. The relative standard errors of prediction (RSEP) were calculated for the calibration, validation and analysed data sets. These errors amounted to 3.2-3.6%, 3.5-3.8% and 4.8-5.7% for the three techniques applied, respectively. The proposed procedures can be used as simple, fast and accurate methods for the quantitative analysis of gluten in flour.


Assuntos
Farinha/análise , Glutens/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Triticum/química
10.
Talanta ; 138: 285-289, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25863403

RESUMO

Fat, protein, carbohydrates and dry matter were quantified in commercial bovine milk samples, with the relative standard errors of prediction (RSEP) in the 3.4-6.1% range, using the partial least squares (PLS) method based on Raman spectra of liquid milk samples. Results of a better quality were obtained from a PLS model derived from IR spectra registered using single reflection ATR diamond accessory, which yielded RSEP values of 2.4-4.4%. The data indicated IR single reflection ATR spectroscopy and Raman spectroscopy in combination with multivariate modelling using the PLS method, allowed for the reliable, simultaneous quantitative determination of macronutrients in milk. The low signal to noise ratio of Raman spectra affects the quality of fat quantification especially for strongly defatted milk samples.


Assuntos
Laticínios/análise , Leite/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Espectral Raman/métodos , Animais , Calibragem , Bovinos , Análise dos Mínimos Quadrados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...