Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 15530, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36109554

RESUMO

In this work, we present the laser cleaning of a Rubidium vapor cell and the Raman analysis of the contaminant material to be removed. The optical window of the vapor cell had gradually lost transparency due to the development of an opaque layer of unknown composition at the inner side during the normal operation of the cell. Laser cleaning was successfully performed by a frequency-doubled Nd:YAG laser focusing the beam inside the cell, avoiding any possible damage to the window. A single laser pulse was enough to clear away the black discoloration at the focal spot and locally restore the transparency of the window. The Raman spectra of the deposit showed peaks not yet described in the literature. Comparison with known Rubidium germanate spectra and simulation results strongly suggested that the unknown material was Rubidium silicate.

2.
Geroscience ; 44(2): 585-595, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34985588

RESUMO

Respiratory transmission of SARS-CoV-2 from one older patient to another by airborne mechanisms in hospital and nursing home settings represents an important health challenge during the COVID-19 pandemic. However, the factors that influence the concentration of respiratory droplets and aerosols that potentially contribute to hospital- and nursing care-associated transmission of SARS-CoV-2 are not well understood. To assess the effect of health care professional (HCP) and patient activity on size and concentration of airborne particles, an optical particle counter was placed (for 24 h) in the head position of an empty bed in the hospital room of a patient admitted from the nursing home with confirmed COVID-19. The type and duration of the activity, as well as the number of HCPs providing patient care, were recorded. Concentration changes associated with specific activities were determined, and airway deposition modeling was performed using these data. Thirty-one activities were recorded, and six representative ones were selected for deposition modeling, including patient's activities (coughing, movements, etc.), diagnostic and therapeutic interventions (e.g., diagnostic tests and drug administration), as well as nursing patient care (e.g., bedding and hygiene). The increase in particle concentration of all sizes was sensitive to the type of activity. Increases in supermicron particle concentration were associated with the number of HCPs (r = 0.66; p < 0.05) and the duration of activity (r = 0.82; p < 0.05), while submicron particles increased with all activities, mainly during the daytime. Based on simulations, the number of particles deposited in unit time was the highest in the acinar region, while deposition density rate (number/cm2/min) was the highest in the upper airways. In conclusion, even short periods of HCP-patient interaction and minimal patient activity in a hospital room or nursing home bedroom may significantly increase the concentration of submicron particles mainly depositing in the acinar regions, while mainly nursing activities increase the concentration of supermicron particles depositing in larger airways of the adjacent bed patient. Our data emphasize the need for effective interventions to limit hospital- and nursing care-associated transmission of SARS-CoV-2 and other respiratory pathogens (including viral pathogens, such as rhinoviruses, respiratory syncytial virus, influenza virus, parainfluenza virus and adenoviruses, and bacterial and fungal pathogens).


Assuntos
COVID-19 , SARS-CoV-2 , Aerossóis , Hospitais , Humanos , Pandemias
3.
Sci Rep ; 10(1): 22430, 2020 12 31.
Artigo em Inglês | MEDLINE | ID: mdl-33384436

RESUMO

The new coronavirus disease 2019 (COVID-19) has been emerged as a rapidly spreading pandemic. The disease is thought to spread mainly from person-to-person through respiratory droplets produced when an infected person coughs, sneezes, or talks. The pathogen of COVID-19 is the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). It infects the cells binding to the angiotensin-converting enzyme 2 receptor (ACE2) which is expressed by cells throughout the airways as targets for cellular entry. Although the majority of persons infected with SARS-CoV-2 experience symptoms of mild upper respiratory tract infection, in some people infections of the acinar airways result in severe, potentially fatal pneumonia. However, the induction of COVID-19 pneumonia requires that SARS-CoV-2 reaches the acinar airways. While huge efforts have been made to understand the spread of the disease as well as the pathogenesis following cellular entry, much less attention is paid to how SARS-CoV-2 from the environment reach the receptors of the target cells. The aim of the present study is to characterize the deposition distribution of SARS-CoV-2 in the airways upon exposure to cough-generated droplets and aerosol particles. For this purpose, the Stochastic Lung Deposition Model has been applied. Particle size distribution, breathing parameters supposing normal breathing through the nose, and viral loads were taken from the literature. We found that the probability of direct infection of the acinar airways due to inhalation of particles emitted by a bystander cough is very low. As the number of viruses deposited in the extrathoracic airways is about 7 times higher than in the acinar airways, we concluded that in most cases COVID-19 pneumonia must be preceded by SARS-CoV-2 infection of the upper airways. Our results suggest that without the enhancement of viral load in the upper airways, COVID-19 would be much less dangerous. The period between the onset of initial symptoms and the potential clinical deterioration could provide an opportunity for prevention of pneumonia by blocking or significantly reducing the transport of viruses towards the acinar airways. Therefore, even non-specific treatment forms like disinfection of the throat and nasal and oral mucosa may effectively keep the viral load of the upper airways low enough to avoid or prolong the progression of the disease. In addition, using a tissue or cloth in order to absorb droplets and aerosol particles emitted by own coughs of infected patients before re-inhalation is highly recommended even if they are alone in quarantine.


Assuntos
COVID-19/patologia , COVID-19/transmissão , Fenômenos Fisiológicos Respiratórios , Aerossóis , Enzima de Conversão de Angiotensina 2/metabolismo , Tosse , Humanos , Receptores Virais/metabolismo , Sistema Respiratório/virologia , SARS-CoV-2/genética , SARS-CoV-2/patogenicidade , Carga Viral
4.
Talanta ; 85(3): 1253-9, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21807179

RESUMO

A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO(3)) and bismuth tellurite (Bi(2)TeO(5)) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 µL aliquot of liquid carbon tetrachloride (CCl(4)) was dispensed with a conventional autosampler into the graphite tube. The CCl(4) was partially dried at 80°C under the mini-flow (40 cm(3) min(-1)) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 1900-2100°C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100°C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 µmol L(-1) for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 µmol L(-1) were found for Er and Nd, respectively. These LOD data correspond to 0.68 µmol mol(-1) Er and 11 µmol mol(-1) Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.


Assuntos
Tetracloreto de Carbono/química , Halogenação , Calefação , Espectrofotometria Atômica/métodos , Bismuto/química , Calibragem , Nióbio/química , Óxidos/química , Reprodutibilidade dos Testes , Espectrometria por Raios X/métodos , Espectrofotometria Atômica/instrumentação , Telúrio/química
5.
Int J Environ Health Res ; 21(6): 427-40, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21563012

RESUMO

Although pollen is one of the most widespread agents that can cause allergy, its airway transport and deposition is far from being fully explored. The objective of this study was to characterize the airway deposition of pollens and to contribute to the debate related to the increasing number of asthma attacks registered after thunderstorms. For the quantification of the deposition of inhaled pollens in the airways computer simulations were performed. Our results demonstrated that smaller and fragmented pollens may penetrate into the thoracic airways and deposit there, supporting the theory that fragmented pollen particles are responsible for the increasing incidence of asthma attacks following thunderstorms. Pollen deposition results also suggest that children are the most exposed to the allergic effects of pollens. Finally, pollens between 0.5 and 20 µm deposit more efficiently in the lung of asthmatics than in the healthy lung, especially in the bronchial region.


Assuntos
Poluentes Atmosféricos/análise , Exposição por Inalação/análise , Pólen , Asma/epidemiologia , Simulação por Computador , Humanos , Pulmão/fisiologia , Método de Monte Carlo , Tamanho da Partícula , Chuva , Fatores de Risco , Processos Estocásticos
6.
Environ Sci Technol ; 45(4): 1608-15, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21280648

RESUMO

As a result of a tragic industrial accident, a highly alkaline red mud sludge inundated settlements and agricultural areas near Ajka, Hungary on October 4, 2010. One of the major concerns about the aftermaths of the accident is the potential health effects of vast amounts of fugitive dust from red mud sediment. Thus, we studied the chemical and physical properties of particles of red mud and its respirable fugitive dust, and performed toxicity measurements. Under unfavorable meteorological conditions dry red mud sediment could emit very high amounts of respirable alkaline particles into the air. The number size distribution of fugitive dust peaks above 1 µm aerodynamic diameter; therefore, its inhalation is unlikely to affect the deep regions of the lungs. No significant mineralogical or elemental fractionation was observed between the sediment and dust, with the major minerals being hematite, cancrinite, calcite, and hydrogarnet. Although the high resuspension potential and alkalinity might pose some problems such as the irritation of the upper respiratory tract and eyes, based on its size distribution and composition red mud dust appears to be less hazardous to human health than urban particulate matter.


Assuntos
Acidentes de Trabalho , Poeira , Monitoramento Ambiental , Sedimentos Geológicos/química , Humanos , Hungria , Exposição por Inalação , Medição de Risco , Esgotos , População Urbana
7.
Appl Opt ; 48(31): 6026-34, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19881670

RESUMO

Digital holography replaces the permanent recording material of analog holography with an electronic light sensitive matrix detector, but besides the many unique advantages, this brings serious limitations with it as well. The limited resolution of matrix detectors restricts the field of view, and their limited size restricts the resolution in the reconstructed holographic image. Scanning the larger aerial hologram (the interference light field of the object and reference waves in the hologram plane) with the small matrix detector or using magnification for the coarse matrix detector at the readout of the fine-structured aerial hologram, these are straightforward solutions but have been exploited only partially until now. We have systematically applied both of these approaches and have driven them to their present extremes, over half a magnitude in extensions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...