Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 126(1-4): 185-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17616545

RESUMO

In modern radiation therapy such as intensity modulated radiation therapy or proton therapy, one is able to cover the target volume with improved dose conformation and to spare surrounding tissue with help of modern measurement techniques. Novel thermoluminescence dosimetry (TLD) foils, developed from the hot-pressed mixture of LiF:Mg,Cu,P (MCP TL) powder and ethylene-tetrafluoroethylene (ETFE) copolymer, have been applied for 2-D dosimetry of radiotherapeutical proton beams at INFN Catania and IFJ Krakow. A TLD reader with 70 mm heating plate and CCD camera was used to read the 2-D emission pattern of irradiated foils. The absorbed dose profiles were evaluated, taking into account correction factors specific for TLD such as dose and energy response. TLD foils were applied for measuring of dose distributions within an eye phantom and compared with predictions obtained from the MCNPX code and Eclipse Ocular Proton Planning (Varian Medical Systems) clinical radiotherapy planning system. We demonstrate the possibility of measuring 2-D dose distributions with point resolution of about 0.5 x 0.5 mm(2).


Assuntos
Metais/efeitos da radiação , Nêutrons , Terapia com Prótons , Radiometria/instrumentação , Radiometria/métodos , Dosimetria Termoluminescente/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
2.
Radiat Prot Dosimetry ; 118(2): 213-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16735573

RESUMO

At the Institute of Nuclear Physics of the Polish Academy of Sciences (IFJ) in Kraków, a two-dimensional (2-D) thermoluminescence (TL) dosimetry system was developed within the MAESTRO (Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology) 6 Framework Programme and tested by evaluating 2-D dose distributions around radioactive sources. A thermoluminescent detector (TLD) foil was developed, of thickness 0.3 mm and diameter 60 mm, containing a mixture of highly sensitive LiF:Mg,Cu,P powder and Ethylene TetraFluoroEthylene (ETFE) polymer. Foil detectors were irradiated with (226)Ra brachytherapy sources and a (90)Sr/(90)Y source. 2-D dose distributions were evaluated using a prototype planar (diameter 60 mm) reader, equipped with a 12 bit Charge Coupled Devices (CCD) PCO AG camera, with a resolution of 640 x 480 pixels. The new detectors, showing a spatial resolution better than 0.5 mm and a measurable dose range typical for radiotherapy, can find many applications in clinical dosimetry. Another technology applicable to clinical dosimetry, also developed at IFJ, is the Si microstrip detector of size 95 x 95 mm(2), which may be used to evaluate the dose distribution with a spatial resolution of 120 microm along one direction, in real-time mode. The microstrip and TLD technology will be further improved, especially to develop detectors of larger area, and to make them applicable to some advanced radiotherapy modalities, such as intensity modulated radiotherapy (IMRT) or proton radiotherapy.


Assuntos
Radiometria/instrumentação , Radiometria/métodos , Radioterapia/métodos , Dosimetria Termoluminescente/métodos , Braquiterapia/métodos , Humanos , Imagens de Fantasmas , Fótons , Prótons , Doses de Radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
3.
Radiat Prot Dosimetry ; 120(1-4): 117-20, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16614087

RESUMO

The dosimetry around the X-ray tube with a needle-like anode (NAXT), developed at the Institute of Nuclear Studies, for interstitial brachytherapy has been performed using (1) dye films (Gafchromic XR-T), (2) large-area thermoluminescent (TL) detectors--prepared either by gluing TL powder onto thin Al foil (so-called planar detectors with spatial resolution of 0.1 mm) and (3) miniature (2 mm diameter and 0.5 mm thick) TL detectors. The measurements were performed in following geometries. (1) Needle inside a PMMA cylinder--the planar TL detector mounted on the surface of the cylinder. (2) Needle inside a thick block of PMMA and TL detector mounted vertically 7 mm from needle axis. TL detectors were read with the planar (2D) thermoluminescence reader, developed at IFJ, with a sensitive CCD (charge couple device) camera. Gafchromic films were evaluated with a system based on Agfa Arcus 1200 scanner and calibrated with X rays (35 kV) filtered with 0.03 mm Mo and with Co-60 photons. The intensity distribution of TL light on the planar detector was calibrated in terms of absorbed dose to water, using (137)Cs gamma-rays. TL planar detectors seem to be a promising tool for 2D dosimetry of miniature X-ray sources. Obtained results for TLDs and Gafchromic films seem to be comparable but differences have been found. Both methods are useful for measurements of dose distribution around the NAXT X-rays source.


Assuntos
Braquiterapia/instrumentação , Dosimetria Fotográfica/instrumentação , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Corantes/química , Corantes/efeitos da radiação , Eletrodos , Dosimetria Fotográfica/métodos , Agulhas , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos , Raios X
4.
Radiat Prot Dosimetry ; 120(1-4): 129-32, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16614089

RESUMO

A novel method of determining two-dimensional (2-D) dose distributions is presented, using in-house developed, large-area (a few cm(2)) thermoluminescent (TL) detectors based on LiF powder plated on Al foil. An in-house developed planar large-area TL reader equipped with a coupled charge device (CCD) camera is used for readout, providing digital images of 2-D dose distributions on the surface of these large-area TL detectors. The capability of the newly developed system is demonstrated by mapping 2-D dose distributions around a brachytherapy source, at dose ranges and source geometries relevant for clinical radiotherapy. Examples of local and dynamic evaluation of TL output from conventional TL detectors are also shown.


Assuntos
Semicondutores , Processamento de Sinais Assistido por Computador/instrumentação , Dosimetria Termoluminescente/instrumentação , Transdutores , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
5.
Radiat Prot Dosimetry ; 122(1-4): 36-40, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17351268

RESUMO

The analytical model of Xapsos used for calculating microdosimetric spectra is based on the observation that straggling of energy loss can be approximated by a log-normal distribution of energy deposition. The model was applied to calculate microdosimetric spectra in spherical targets of nanometer dimensions from heavy ions at energies between 0.3 and 500 MeV amu(-1). We recalculated the originally assumed 1/E(2) initial delta electrons spectrum by applying the Continuous Slowing Down Approximation for secondary electrons. We also modified the energy deposition from electrons of energy below 100 keV, taking into account the effective path length of the scattered electrons. Results of our model calculations agree favourably with results of Monte Carlo track structure simulations using MOCA-14 for light ions (Z = 1-8) of energy ranging from E = 0.3 to 10.0 MeV amu(-1) as well as with results of Nikjoo for a wall-less proportional counter (Z = 18).


Assuntos
Biopolímeros/química , Biopolímeros/efeitos da radiação , Íons Pesados , Modelos Químicos , Nanoestruturas/química , Nanoestruturas/efeitos da radiação , Radiometria/métodos , Simulação por Computador , Transferência Linear de Energia , Modelos Moleculares , Tamanho da Partícula , Doses de Radiação , Espalhamento de Radiação
6.
Radiat Prot Dosimetry ; 122(1-4): 378-81, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17261540

RESUMO

The microdosimetric one hit detector model was applied to calculate the dose response, energy response and relative thermoluminescence (TL) efficiency, eta, of high sensitive LiF:Mg,Cu,P and Al(2)O(3):C detectors after their irradiations by X rays, gamma rays, beta electrons and heavy charged particles (HCP). Microdosimetric distributions in 60 nm targets for photons and beta rays were calculated using the TRION MC track structure code, for HCP using the analytical model of Xapsos with modified transport of secondary electrons and the model of Olko & Booz. The calculated values of eta compare favourably with a broad spectrum of experimental data, including ICHIBAN experiments with HCP. The model offers a method for calculating the thermoluminescence response of TL foils applied to 2-D dosimetry of radiotherapeutic proton beams.


Assuntos
Algoritmos , Transferência Linear de Energia , Modelos Teóricos , Dosimetria Termoluminescente/instrumentação , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
7.
Radiat Prot Dosimetry ; 110(1-4): 623-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353719

RESUMO

In the dosimetry of boron neutron capture therapy (BNCT) beams, thermoluminescent (TL) detectors are typically applied in phantom measurements to determine the spatial distribution of the gamma ray and neutron dose. Pairs of 6LiF and 7LiF are applied to discriminate between the thermal neutron and gamma ray field components, exploiting the high cross section for (n,alpha) reaction of 6Li. At the Institute of Nuclear Physics (INP) in Kraków (Poland) a prototype TL-based measuring set has been constructed and tested. This set consists of a miniature TL detector (of 2 mm diameter and 0.4 mm thickness) placed inside a miniature container made of non-thermoluminescent 6LiF. The outer dimensions of the set are 4.5 mm diameter and 1.4 mm thickness, enabling its application in place of a thermoluminescence dosemeter pellet in typical phantoms. The detector sets were tested in the BNCT beam of the Studsvik reactor. By exploiting the ratio of TL signals of the unshielded and shielded detectors, it was possible to estimate the contributions of the thermal and epithermal components of the neutron field.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Raios gama/uso terapêutico , Nêutrons/uso terapêutico , Proteção Radiológica/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Dosimetria Termoluminescente/instrumentação , Transdutores , Carga Corporal (Radioterapia) , Terapia por Captura de Nêutron de Boro/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Miniaturização , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...