1.
Artif Organs ; 39(5): 409-15, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25818075

RESUMO

Patients with aortic stenosis tend to develop ventricular conduction problems, which are known adverse events following transcatheter aortic valve implantation (TAVI). Changes in ventricular conduction status after TAVI were analyzed in 195 consecutive patients from a single institute registered in FRANCE2 between February 2010 and June 2012. Among the 195 patients, 29 had a prior pacemaker implantation (+PM) and 6 had acute catastrophic hemodynamics that made a full electrocardiogram (ECG) unavailable. Among the remaining 160, PM was newly required in 28 (17.5%, PM+) but not in 132 (PM-), which included 21 (13.1%) who developed new left bundle branch block (BBB), 12 (7.5%) had right BBB, and 99 (61.9%) had no change. While PM requirement had no correlation with preoperative factors, there was significant association with the development of right BBB with Edwards Sapien/XT (P = 0.003), and new left BBB (P = 0.012) and complete heart block requiring PM with CoreValve (22.6% vs. Edwards Sapien/XT, 7.4%, P = 0.016). Whereas postoperative survival regarding PM status (+PM, PM+, PM-), vascular access, valve size or type showed no difference, delayed heart block (n = 12, Day 2 or later) was associated with poor survival (P = 0.038) compared with the remaining PM+ patients with earlier onset (n = 16, Day 0 or 1). As a result, PM+ patients (n = 28) had significantly longer intensive care unit (ICU) stay and hospitalization than PM- or +PM patients. The results suggest that ventricular conduction problems requiring PM occurred more frequently after TAVI (17.5%) than with usual surgical replacement. Nonetheless, conduction problems failed to influence postoperative survival for up to 3 years on average with use of PM, but therefore did increase medical costs.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Ventrículos do Coração/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...