Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Med ; 126(3): 484-493, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32902826

RESUMO

PURPOSE: To compare size and morphologic features of three-dimensional aneurysm models, obtained with a semi-automated segmentation software (Stroke VCAR, GE, USA) from cerebral CT angiography (CTA) data, to three-dimensional aneurysm models obtained with digital subtraction angiography (DSA, with 3D rotational angiography acquisition-3DRA), considered as the reference standard. METHODS: In this retrospective study, we reviewed 132 patients, with a total number of 137 intracranial aneurysm, who underwent CTA and subsequent DSA examination, supplemented with 3DRA. We compared neck length, short axis and long axis measured on 3DRA model to the same variables measured on 3D-CTA model by two blinded readers and to the automatic software dimensions. Therefore, statistics analysis assessed intra-observer and inter-observer variability and differences between patients with or without subarachnoid hemorrhage (SAH). RESULTS: There were no significant differences in short-axis and long-axis measurements between 3D angiographic and 3D-CTA models, while comparison of neck lengths revealed a statistically significant difference, which tended to be greater for smaller neck lengths (partial volume effect and "kissing vessels" artifact). There were significant differences between manual and automatic data measured for the same three variables, and the presence of SAH did not affect aneurysm 3D reconstruction. Inter-observer agreement resulted moderate for neck length and substantial for short axis and long axis. CONCLUSION: The examined 3D-CTA segmentation system is a reproducible procedure for aneurysm morphologic characterization and, in particular, for assessment of aneurysm sac dimensions, but considerable carefulness is required in neck length interpretation.


Assuntos
Angiografia Digital/métodos , Angiografia por Tomografia Computadorizada/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral/métodos , Feminino , Humanos , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estatísticas não Paramétricas , Hemorragia Subaracnóidea/diagnóstico por imagem , Adulto Jovem
2.
AJNR Am J Neuroradiol ; 37(2): 279-84, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26405085

RESUMO

BACKGROUND AND PURPOSE: The flow-diverter stent has been proved a feasible, safe, and efficient technique, particularly for the treatment of large and broad-neck carotid siphon aneurysms. Wide-neck bifurcation aneurysms remain, in some cases, a challenge for neurointerventionalists. We report the outcomes of the treatment of saccular middle cerebral artery bifurcation aneurysms with flow diversion in our institution. MATERIALS AND METHODS: From the institution data base, all saccular, nondissecting MCA bifurcation aneurysms, treated with flow-diverter stents, were retrospectively reviewed. Technical issues, immediate posttreatment and follow-up angiographic findings, and clinical outcomes were assessed. RESULTS: Fourteen patients with 15 aneurysms were included in the study. Ischemic complications, as confirmed by MR imaging, occurred in 6 patients (43%). Procedure-related morbidity and mortality at last follow-up were 21% and 0%, respectively. Angiographic follow-up was available for 13 aneurysms, with a mean follow-up of 16 months. Complete occlusion was obtained for 8 aneurysms (62%). CONCLUSIONS: Compared with other available therapeutic options, the flow-diverter stent does not appear to be a suitable solution for the treatment of saccular MCA bifurcation aneurysms.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adolescente , Adulto , Idoso , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 36(2): 330-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25339649

RESUMO

BACKGROUND AND PURPOSE: Flow-diverting stents can be used to treat intracranial aneurysms that are not amenable to treatment with coils. We analyzed ophthalmic consequences due to coverage of the origin of the ophthalmic artery by flow-diverting stents for the treatment of internal carotid artery aneurysms. MATERIALS AND METHODS: From April 2009 to April 2013, the clinical and angiographic outcomes of all 28 patients treated for aneurysms with flow-diverting stents covering the origin of the ophthalmic artery were prospectively collected. The origin of the ophthalmic artery in relation to the target aneurysm was classified by using a 4-type classification. A complete ophthalmic examination was performed by a single ophthalmologist 48 hours before and 1 week after covering the ophthalmic artery. RESULTS: Ophthalmic artery patency was normal at the end of endovascular treatment in 24/28 cases (85.7%). With extensive ophthalmic examinations, 11 patients (39.3%) showed new ophthalmic complications. Patients with the ophthalmic artery originating from the aneurysm sac were at high risk for retinal emboli (4/5, 80%). Patients with the ophthalmic artery originating from the inner curve of the carotid siphon were at high risk for optic nerve ischemic atrophy (3/4, 75%). CONCLUSIONS: This prospective study shows that covering the ophthalmic artery with a flow-diverting stent is not without potential complications. Ophthalmic complications can occur but are often not diagnosed. The anatomic disposition of the ophthalmic artery in relation to the carotid siphon and aneurysm should be clearly understood because some configurations have a higher risk. When not required, covering of the ophthalmic artery by flow-diverting stents should be avoided.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/cirurgia , Artéria Oftálmica/cirurgia , Stents/efeitos adversos , Adulto , Idoso , Artéria Carótida Interna/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
4.
Radiol Med ; 118(3): 415-30, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22872461

RESUMO

PURPOSE: The authors evaluated the usefulness of three-dimensional rotational angiography (3DRA) in surgical planning and postoperative evaluation of cerebral aneurysms. MATERIALS AND METHODS: A total of 111 consecutive aneurysms in 100 patients (32 emergency referrals due to haemorrhage) were evaluated with 3DRA over a period of 3 years. The rotational study was always performed with a single injection of 20 cc of contrast agent in the afferent vessel after diagnostic cerebral angiography in the two orthogonal projections. Three-dimensional reconstructions were obtained for the pre- and postoperative assessment. RESULTS: Three-dimensional RA provides a virtual view of the surgical field with the same orientation required for the surgical approach and, compared with surgical findings, reliably defined location, orientation, morphology and relationship with parent vessels of the aneurysm in all cases. Postoperatively, it allowed better assessment of any residual lesion and of the relationship between surgical clips and parent vessels, compared with standard 2D angiography. CONCLUSIONS: 3DRA is a reliable method for preliminary assessment of cerebral aneurysms undergoing surgery. It provides multiple projections with a preview of the surgical field and study of lesion characteristics, which can help achieve faster and safer surgery. Compared with 2D angiography, the 3D model, with its multiple views, allows better assessment of postoperative outcomes. The method also significantly reduces the number of angiographic projections and therefore radiation and contrast-medium dose to the patient.


Assuntos
Angiografia Cerebral/métodos , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Análise de Variância , Meios de Contraste , Craniotomia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...