Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Acta Anaesthesiol Scand ; 54(6): 744-50, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20397977

RESUMO

BACKGROUND: The role of gravity in the redistribution of pulmonary blood flow during one-lung ventilation (OLV) has been questioned recently. To address this controversial but clinically important issue, we used an experimental approach that allowed us to differentiate the effects of gravity from the effects of hypoxic pulmonary vasoconstriction (HPV) on arterial oxygenation during OLV in patients scheduled for thoracic surgery. METHODS: Forty patients with chronic obstructive pulmonary disease scheduled for right lung tumour resection were randomized to undergo dependent (left) one-lung ventilation (D-OLV; n=20) or non-dependent (right) one-lung ventilation (ND-OLV; n=20) in the supine and left lateral positions. Partial pressure of arterial oxygen (PaO2) was measured as a surrogate for ventilation/perfusion matching. Patients were studied before surgery under closed chest conditions. RESULTS: When compared with bilateral lung ventilation, both D-OLV and ND-OLV caused a significant and equal decrease in PaO(2) in the supine position. However, D-OLV in the lateral position was associated with a higher PaO2 as compared with the supine position [274.2 (77.6) vs. 181.9 (68.3) mmHg, P<0.01, analysis of variance (ANOVA)]. In contrast, in patients undergoing ND-OLV, PaO2 was always lower in the lateral as compared with the supine position [105.3 (63.2) vs. 187 (63.1) mmHg, P<0.01, ANOVA]. CONCLUSION: The relative position of the ventilated vs. the non-ventilated lung markedly affects arterial oxygenation during OLV. These data suggest that gravity affects ventilation-perfusion matching independent of HPV.


Assuntos
Gravitação , Oxigênio/sangue , Posicionamento do Paciente , Postura/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Respiração Artificial/métodos , Idoso , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Cuidados Intraoperatórios , Pulmão/fisiopatologia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Pressão Parcial , Pneumonectomia , Circulação Pulmonar , Ventilação Pulmonar , Testes de Função Respiratória , Decúbito Dorsal/fisiologia
2.
Ann Fr Anesth Reanim ; 28(10): 868-77, 2009 Oct.
Artigo em Francês | MEDLINE | ID: mdl-19854607

RESUMO

The different concepts treating of "residual curarization" were presented according to two directions: the analysis of their contents--epidemiologic, clinical, instrumental--and the description of the pharyngeal striated muscles functions in these contexts. It appears that certain, too marked, "residual curarization" levels remain a well-evidenced factor increasing some morbidities in numerous clinical situations. All the methods of instrumental monitoring of the level of curarization--mecanography, electromyography, accelerometry--appeared useful to document the levels of "residual curarization" before patient's extubation or awakening. Today, for our speciality, it became particularly clear that: neither the selected muscle-- adductor pollicis--, neither the test currently privileged--train-of-four 2Hz--, nor the thresholds currently selected--0.90 or 1.00--did not constitute the unavoidable proof of a "residual curarization" complete absence. For the healthy volunteer receiving a curare, a train of four of the adductor pollicis greater than 0.90 can exist in presence of spirometric alterations evidencing the lack of adequate pharyngeal dilatation. In daily routine, the pharyngeal control is already disturbed by numerous molecules including: benzodiazepines, halogenated vapours, propofol, i.e. even under non-hypnotic concentrations. Faced to such evidences, our medical speciality will, undoubtedly, have to acquire new knowledge to develop muscle relaxant management control processes eliminating the surmorbidities related to "residual curarization". These tests must be validated also to exclude morbidity-prone dysfunctions of the pharyngeal striated muscles. Considering this new paradigm would be a major safety evolution for our speciality.


Assuntos
Anestésicos/farmacologia , Monitoramento de Medicamentos , Fármacos Neuromusculares não Despolarizantes/farmacologia , Músculos Faríngeos/efeitos dos fármacos , Humanos
3.
Anesth Analg ; 100(5): 1348-1351, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15845682

RESUMO

In this study we quantitatively evaluated, by a stable paralysis/stable infusion rate method, the difference between two standardized paralysis levels--train-of-four (TOF) count of 2 responses and posttetanic count (PTC) of 2. Ten ASA physical status I-II consenting adult patients scheduled for elective surgery were anesthetized (sufentanil/propofol), tracheally intubated, mechanically normoventilated with a fixed O(2)/air mixture, and normothermic; oropharynx and thenar temperatures were maintained above 36 degrees and 32.5 degrees C, respectively. After partial recovery from 200 microg/kg mivacurium (MIV), stable tactile TOF and PTC counts of 2 paralysis levels were induced on the adductor pollicis muscle by manual adjustments of an infusion pump containing MIV. The paralysis levels and the infusion rates were considered as stable once they remained constant at 4 consecutive time points separated by 5 min each. Infusion rates observed were: TOF count 2-6 (2-11) and PTC 2-17 (3-18) microg . kg(-1) . min(-1) (P < 0.001; Wilcoxon's paired comparison test). Under the present conditions, obtaining and maintaining a PTC of 2 requires MIV infusion rates far in excess of the "standard" recommendations mentioned in the literature for MIV infusion management.


Assuntos
Isoquinolinas/administração & dosagem , Relaxamento Muscular/efeitos dos fármacos , Fármacos Neuromusculares não Despolarizantes/farmacologia , Adulto , Anestesia , Feminino , Humanos , Infusões Intravenosas , Isoquinolinas/farmacologia , Masculino , Pessoa de Meia-Idade , Mivacúrio
4.
Br J Anaesth ; 88(1): 56-60, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11881884

RESUMO

BACKGROUND: We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. METHODS: We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. RESULTS: PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. CONCLUSION: A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.


Assuntos
Respiração por Pressão Positiva Intrínseca/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Respiração Artificial/métodos , Mecânica Respiratória , Toracotomia , Idoso , Dióxido de Carbono/sangue , Humanos , Pessoa de Meia-Idade , Monitorização Intraoperatória , Oxigênio/sangue , Pressão Parcial
5.
Anesthesiology ; 93(3): 653-61, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10969297

RESUMO

BACKGROUND: The predictive accuracy of target concentration infusions of propofol has been documented only for less than 4 h, and no prospective study of sufentanil target controlled infusion is available. The authors investigated the predictive accuracy of pharmacokinetic models for propofol and sufentanil coadministered during long-lasting surgery. METHODS: Ten patients, American Society of Anesthesiologists physical status I and II, were studied during extended cervicofacial surgery. Target controlled infusion of propofol and sufentanil was administered during surgery using decisional algorithms, taking into consideration pain assessment, hemodynamic changes, and peroperative blood losses. Intrasubject data analysis included calculation of performance error, median performance error, median absolute performance error, divergence, and wobble. RESULTS: The range of plasma target concentrations was 2-5 microgram/ml for propofol and 0.2-1 ng/ml for sufentanil. Median performance error was -12.1% for propofol and -10% for sufentanil. The wobble values were 11.6% and 22.3% for propofol and sufentanil, respectively. The pharmacokinetic sets used slightly overpredicted the concentrations, with negative values of divergence of 2.92% and 0.22% units/h for propofol and sufentanil, for a mean infusion period of 762 min. CONCLUSIONS: This prospective study demonstrates the predictive accuracy of the pharmacokinetic model for sufentanil infusion and confirms that for propofol during long-lasting surgery using standardized rules for the management of target controlled infusion and blood loss replacement.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Propofol/administração & dosagem , Sufentanil/administração & dosagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Propofol/farmacocinética , Estudos Prospectivos , Sufentanil/farmacocinética
6.
Anesth Analg ; 90(1): 35-41, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10624972

RESUMO

UNLABELLED: We compared the effects of position and fraction of inspired oxygen (F(IO)2) on oxygenation during thoracic surgery in 24 consenting patients randomly assigned to receive an F(IO)2 of 0.4 (eight patients, Group 0.4), 0.6 (eight patients, Group 0.6), or 1.0 (eight patients, Group 1.0) during the periods of two-lung (TLV) and one-lung ventilation (OLV) in the supine and lateral positions. TLV and OLV were maintained while the patients were first in the supine and then in the lateral position for 15 min each. Thereafter, respiratory mechanical data were obtained, and arterial blood gas samples were drawn. Pao2 decreased during OLV compared with TLV in both the supine and lateral positions. In all three groups, Pao2 was significantly higher during OLV in the lateral than in the supine position: 101 (72-201) vs 63 (57-144) mm Hg in Group 0.4; 268 (162-311) vs 155 (114-235) mm Hg in Group 0.6; and 486 (288-563) vs 301 (216-422) mm Hg in Group 1.0, respectively (P < 0.02, Wilcoxon's signed rank test). We conclude that, compared with the supine position, gravity augments the redistribution of perfusion as a result of hypoxic pulmonary vasoconstriction, when patients are in the lateral position, which explains the higher Pao2 during OLV. IMPLICATIONS: This study compares oxygenation during thoracic surgery during periods of two-lung and one-lung ventilation with patients in the supine and lateral positions when using three different fraction of inspired oxygen values. Arterial oxygen tension was decreased in all three groups during one-lung ventilation in comparison with the two-lung ventilation values, but the decrease was significantly less in the lateral, compared with the supine position.


Assuntos
Pneumopatias Obstrutivas/fisiopatologia , Consumo de Oxigênio/fisiologia , Postura/fisiologia , Respiração Artificial , Adulto , Idoso , Gasometria , Método Duplo-Cego , Feminino , Humanos , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Testes de Função Respiratória , Mecânica Respiratória/fisiologia , Decúbito Dorsal/fisiologia
7.
Anesth Analg ; 87(1): 185-9, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9661571

RESUMO

UNLABELLED: We were looking for a clinical test to indicate a train-of-four (TOF) ratio of approximately 0.9. We compared the adductor pollicis muscle (AP) visually evaluated response to ulnar nerve 100-Hz, 5-s tetanus (RF100 Hz) with the measured AP TOF ratio in 30 ASA physical status I or II adult anesthetized (propofol, sufentanil, N2O/O2) patients. After the induction of anesthesia, the left ulnar nerve was stimulated at the wrist (single twitch and TOF) and the resultant isometric force was measured. When TOF was assessed, the independent investigators, unaware of the left AP-measured TOF ratios, visually evaluated the presence or absence of AP fading elicited by right ulnar nerve 100-Hz, 5-s tetanus. The 30 patients were randomly allocated to receive either 0.5 mg/kg atracurium (n = 15) or 0.1 mg/kg vecuronium (n = 15). The neuromuscular blockade was allowed to resolve spontaneously. A multiple logistic regression analysis was performed by computing the 771 visual observations. The probabilities of success of 100-Hz, 5-s tetanus to detect TOF ratios of 0.8, 0.85, and 0.9 were 99%, 96%, and 67%, respectively. The sensitivity and specificity of 100-Hz, 5-s tetanus as an indicator of TOF ratios of 0.85 and 0.9 are 100% and 75%, 54% and 67%, respectively. We conclude that RF100 Hz visual assessment seems to be highly sensitive in evaluating residual paralysis, as the absence of RF100 Hz visual fading at the AP is compatible with a TOF ratio > 0.85. IMPLICATIONS: After the administration of muscle relaxants, the absence of visual fading at the adductor pollicis, elicited in anesthetized patients by 100-Hz, 5-s tetanus, is compatible with a train-of four ratio > 0.85. Therefore, clinical observation of fading after 100-Hz, 5-s tetanus seems to be a highly sensitive test in evaluating residual paralysis.


Assuntos
Anestesia Geral/métodos , Estimulação Elétrica , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/inervação , Nervo Ulnar/efeitos dos fármacos , Nervo Ulnar/fisiologia , Adulto , Atracúrio , Humanos , Contração Isométrica/efeitos dos fármacos , Contração Isométrica/fisiologia , Pessoa de Meia-Idade , Fármacos Neuromusculares não Despolarizantes , Brometo de Vecurônio
8.
J Cardiothorac Vasc Anesth ; 12(2): 137-41, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9583541

RESUMO

OBJECTIVE: To examine the effects of end-inspiratory pause (EIP) of different durations on pulmonary mechanics and gas exchange during one-lung ventilation (OLV) for thoracic surgery. DESIGN: A prospective clinical study. SETTING: A university hospital. PARTICIPANTS: Eleven patients undergoing elective pulmonary resection with pulmonary hyperinflation on their preoperative pulmonary function studies. INTERVENTIONS: Patients were anesthetized, paralyzed, and intubated with a double-lumen endotracheal tube. Their lungs were ventilated with a Siemens 900C ventilator (Siemens; Solna, Sweden), with constant inspiratory flow. Tidal volume, respiratory rate, and inspiratory time were kept constant during the study. MEASUREMENTS AND RESULTS: During one-lung ventilation in the lateral decubitus position, three levels of EIP (0%, 10%, and 30%) were applied to the dependent lung in random order. After 15 minutes on the given ventilatory pattern, end-inspiratory and end-expiratory occlusions of at least 5 seconds were performed to obtain respiratory mechanics data. Arterial blood gas samples were drawn to assess gas exchange. Altering the duration of end-inspiratory pause from 0% to 30% resulted in a significant increase in intrinsic positive end-expiratory pressure (PEEPi) from 4.1 cm H2O to 7.0 cm H2O. Arterial oxygenation was significantly decreased from 109.7 to 80.5 mmHg and there was a significant negative correlation between the value of partial pressure of arterial oxygen (PaO2) and PEEPi by altering the duration of end-inspiratory pause. From the preoperative pulmonary function studies, the value of functional residual capacity (FRC) (% predicted) showed a significant negative correlation with the PaO2 changes. Partial pressure of arterial carbon dioxide (PaCO2) was not altered significantly by increasing the duration of end-inspiratory pause. CONCLUSION: During the period of OLV in the lateral position of patients with preexisting pulmonary hyperinflation, the magnitude of PEEPi increased and oxygenation decreased significantly, whereas the efficacy of ventilation was not changed by the addition of an end-inspiratory pause to the ventilatory pattern. Because arterial oxygenation is affected by the presence of pulmonary hyperinflation, the method of ventilation should take into account the magnitude of preoperative pulmonary hyperinflation.


Assuntos
Pneumopatias Obstrutivas/fisiopatologia , Pulmão/fisiopatologia , Troca Gasosa Pulmonar/fisiologia , Respiração Artificial/métodos , Procedimentos Cirúrgicos Torácicos , Idoso , Dióxido de Carbono/sangue , Procedimentos Cirúrgicos Eletivos , Humanos , Pessoa de Meia-Idade , Oxigênio/sangue , Pressão Parcial , Pneumonectomia , Respiração com Pressão Positiva , Postura , Estudos Prospectivos
9.
Anesth Analg ; 86(4): 880-4, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9539619

RESUMO

UNLABELLED: We studied patients undergoing elective pulmonary surgery to establish whether observing interrupted expiratory flow (IEF) on the flow-volume curves constructed by the Ultima SV respiratory monitor is a reliable way to identify patients with dynamic pulmonary hyperinflation and intrinsic positive end-expiratory pressure (PEEPi). Patients' tracheas were intubated with a double-lumen endotracheal tube and ventilated with a Siemens 900C constant flow ventilator. In 30 patients, PEEPi was determined by the end-expiratory occlusion (EEO) method during the periods of two-lung and one-lung ventilation in the lateral position. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of the IEF method were calculated. From the 122 measurement pairs, PEEPi was identified with the EEO method in 65 occasions. The mean level of PEEPi was 4.4 cm H2O. During one-lung ventilation, the level of PEEPi and the number of true-positive findings was significantly higher (PEEPi = 4.7 cm H2O and 32 episodes) than during two-lung ventilation (2.9 cm H2O and 19 episodes). When the level of PEEPi was higher than 5 cm H2O, the predictive value of IEF was 100%. The overall sensitivity of the IEF method was 0.78, its specificity was 0.91, and its predictive value was 0.92. In conclusion, examination of the flow-volume curves displayed on the respiratory monitor may identify patients with dynamic hyperinflation and PEEPi during anesthesia for thoracic surgery. IMPLICATIONS: To identify patients with intrinsic positive end-expiratory pressure during anesthesia without the need to interrupt mechanical ventilation, the flow-volume curves of an online respiratory monitor may be examined. The presence of an interrupted expiratory flow may suggest the presence of intrinsic positive end-expiratory pressure with a reasonable accuracy.


Assuntos
Monitorização Intraoperatória/instrumentação , Respiração por Pressão Positiva Intrínseca/diagnóstico , Ventilação Pulmonar/fisiologia , Respiração Artificial , Adulto , Idoso , Procedimentos Cirúrgicos Eletivos , Volume Expiratório Forçado/fisiologia , Capacidade Residual Funcional/fisiologia , Humanos , Inalação/fisiologia , Intubação Intratraqueal/instrumentação , Pulmão/cirurgia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Pressão , Reprodutibilidade dos Testes , Volume Residual/fisiologia , Respiração/fisiologia , Sensibilidade e Especificidade , Toracotomia , Volume de Ventilação Pulmonar/fisiologia , Ventiladores Mecânicos
10.
Br J Anaesth ; 81(6): 854-60, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10211008

RESUMO

We have investigated the pharmacokinetics and pharmacodynamics of propofol in 11 patients with end-stage renal disease (ESRD) compared with nine healthy patients during and after a manually controlled three-stage infusion of propofol 21, 12 and 6 mg kg-1 h-1 lasting a minimum of 2 h. Mean total body clearance was not reduced significantly in the ESRD group (30.66 (SD 8.47) ml kg-1 min-1) compared with the control group (33.75 (7.8) ml kg-1 min-1). ESRD patients exhibited a greater, but not statistically significant, volume of distribution at steady state compared with patients in the control group (11.25 (8.86) vs 5.79 (2.14) litre kg-1, respectively). Elimination half-life values were unchanged by renal failure. Mean times to induction of anaesthesia were similar in both groups: 177 (SD 57) and 167 (58) s for the ESRD and control groups, respectively. Waking time after cessation of propofol infusion was significantly shorter in the ESRD group (474 (156) s) compared with the control group (714 (240) s) (P < 0.05). Mean plasma concentrations on waking were similar. We conclude that the pharmacokinetic and pharmacodynamic profiles of propofol after infusion were not markedly affected by renal failure.


Assuntos
Anestésicos Intravenosos/sangue , Falência Renal Crônica/sangue , Propofol/sangue , Adulto , Período de Recuperação da Anestesia , Anestesia Intravenosa , Anestésicos Intravenosos/farmacocinética , Estado de Consciência/efeitos dos fármacos , Feminino , Meia-Vida , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Propofol/farmacocinética
11.
J Clin Monit ; 13(4): 261-8, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9269620

RESUMO

OBJECTIVE: During surgery, computers can be of great use to support the anesthesiologist in providing task automation. In this paper we describe a closed loop blood pressure controller and show the results of its clinical evaluation. METHODS: The controller is based on a simple and robust Proportional-Integral controller and a supervising, rule based, expert system. Adaptive control is necessary because the sensitivity of the patients to sodium nitroprusside varies over a wide range. Thirty-three clinical tests during cardiac surgery, including the cardiopulmonary bypass phase, were performed. RESULTS: On average the controller was in automatic mode for 90.6 +/- 9.6% of the time. The performance during automatic control showed the mean arterial pressure to be within 10 mmHg of the setpoint for 71.4 +/- 15.5% of the time. The average absolute distance to the setpoint was 8.1 +/- 7.2 mmHg. CONCLUSIONS: The overall performance of the controller was noted as very satisfactory by the anesthesiologists.


Assuntos
Monitores de Pressão Arterial , Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória/instrumentação , Algoritmos , Conversão Análogo-Digital , Valva Aórtica/cirurgia , Automação , Pressão Sanguínea/efeitos dos fármacos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ponte Cardiopulmonar , Sistemas Computacionais , Ponte de Artéria Coronária , Desenho de Equipamento , Estudos de Avaliação como Assunto , Sistemas Inteligentes , Feminino , Hemorreologia , Humanos , Bombas de Infusão , Masculino , Valva Mitral/cirurgia , Nitroprussiato/administração & dosagem , Nitroprussiato/uso terapêutico , Processamento de Sinais Assistido por Computador , Software , Vasodilatadores/administração & dosagem , Vasodilatadores/uso terapêutico
12.
Anesth Analg ; 84(5): 1034-7, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9141927

RESUMO

This investigation analyzed the changes in inspiratory airway pressures during transition from two-lung to one-lung ventilation in patients tracheally intubated with a double-lumen endotracheal tube (DLT) using a classical method of intubation without fiberoptic bronchoscopy. All patients were anesthetized in a standardized fashion. Ventilation was accomplished with the Siemens 900 constant-flow mechanical ventilator (Solna, Sweden). Peak (Ppeak) and plateau (Pplateau) inspiratory airway pressures were recorded with an on-line respiratory monitor before and after clamping the tracheal limb of the DLT. The position of the DLTs was evaluated by fiberoptic bronchoscopy with the patient in supine position. Of the 51 intubations, the DLT was malpositioned in 15 cases (29.5%). Ppeak and Pplateau increased significantly when switched from two-lung ventilation to one-lung ventilation in both correctly and incorrectly positioned DLTs. When the DLT was in a correct position, Ppeak increased by a mean of 55.1% and Pplateau increased by a mean of 41.9%. When the DLT was malpositioned, this increase was significantly larger (74.9% and 68.8%, respectively). Three tests commonly used as markers of malpositioned DLTs were evaluated based on the data of this study, and it was established that, although the pressure differences related to position are statistically significant, as a single value, they cannot be used for clinical decision making.


Assuntos
Pulmão/cirurgia , Respiração Artificial , Mecânica Respiratória , Resistência das Vias Respiratórias , Anestesia Geral , Humanos , Intubação Intratraqueal , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Respiração Artificial/métodos , Sensibilidade e Especificidade
13.
Br J Anaesth ; 77(4): 496-9, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8942335

RESUMO

To test if recovery of neuromuscular transmission is complete after the use of neostigmine under standardized conditions, we have measured adductor pollicis mechanical activity in response to 0.1 Hz (twitch height), train-of-four (TOF) and 100 Hz (RF 100 Hz) ulnar nerve stimulations. We studied 56 adult anaesthetized (thiopentone, fentanyl, nitrous oxide in oxygen) patients, allocated randomly to one of four groups (n = 14) to receive rocuronium (group Roc), vecuronium (group Vec), atracurium (group Atr) or pancuronium (group Pan). Recovery of neuromuscular transmission was studied for 15 min after neostigmine 40 micrograms kg-1 was given at 25% recovery of twitch height. Fifteen minutes after antagonism, the TOF ratio was 0.91 (SEM 0.01), 0.88 (0.02) and 0.92 (0.01) (ns), and RF 100 Hz was 0.78 (0.01), 0.79 (0.02) and 0.78 (0.01) (ns) respectively, in patients in groups Roc, Vec and Atr, respectively. In patients in group Pan, TOF ratio and RF 100 Hz were only 0.76 (0.01) and 0.33 (0.04) respectively (P < 0.01, one-way analysis of variance, Duncan's multiple classification range tests). In contrast with pancuronium, antagonism of rocuronium-, vecuronium- and atracurium-induced neuromuscular blocks produced a similar high degree of recovery of neuromuscular transmission.


Assuntos
Inibidores da Colinesterase/farmacologia , Neostigmina/farmacologia , Junção Neuromuscular/efeitos dos fármacos , Fármacos Neuromusculares não Despolarizantes/antagonistas & inibidores , Transmissão Sináptica/efeitos dos fármacos , Adulto , Androstanóis/antagonistas & inibidores , Anestesia Geral , Atracúrio/antagonistas & inibidores , Humanos , Pessoa de Meia-Idade , Junção Neuromuscular/fisiologia , Pancurônio/antagonistas & inibidores , Rocurônio , Brometo de Vecurônio/antagonistas & inibidores
14.
Acta Anaesthesiol Scand ; 40(5): 574-8, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8792887

RESUMO

BACKGROUND: Since neostigmine was introduced for reversal of neuromuscular block, there has been controversy about the optimum dose for antagonizing neuromuscular block. The purpose of this study was to characterise recovery of neuromuscular transmission following a vecuronium-induced block 15 min after neostigmine administration using different stimulation patterns, and to determine the effects of different doses of neostigmine given at various pre-reversal twitch heights. METHODS: Adductor pollicis (AP) mechanical activity in response to low (0.1 and 2 Hz) and high (50 and 100 Hz) frequency stimulation, was recorded 15 min after 20, 40 and 80 micrograms/kg neostigmine, given to reverse a vecuronium-induced block at 10, 25 and 50% pre-reversal twitch height (TH). Fifty four ASA class I and II anaesthetised (methohexital, fentanyl, N2O/O2) young adult patients were studied and randomly allocated into 9 groups of 6 patients each. RESULTS: In contrast to twitch height (TH) and residual force after 50 Hz, 5 s tetanic stimulation (RF50Hz), the greater sensitivity of train-of-four (TOF) ratio and residual force after 100 Hz, 5 s tetanic stimulation (RF100Hz) points out the best reversal conditions (prereversal TH and the optimal neostigmine dose) (P < 0.001, two-way analysis of variance). The highest reversal scores (about 0.9 TOF ratio and RF100Hz) were obtained when 40 micrograms/kg of neostigmine was given at 25 and 50% TH. A 0.9 TOF ratio was also observed when 40 micrograms/kg of neostigmine was given at 10% TH, but, under these conditions, RF100Hz was only 0.6 (P < 0.05, Duncan test). CONCLUSION: To optimise the reversal action of neostigmine in order to obtain the highest neuromuscular transmission recovery (0.9 TOF ratio and RF100Hz) during a vecuronium-induced neuromuscular block, the 40 micrograms/kg dose has to be given at 25 to 50% recovery of TH.


Assuntos
Inibidores da Colinesterase/administração & dosagem , Neostigmina/administração & dosagem , Bloqueio Neuromuscular , Fármacos Neuromusculares não Despolarizantes/antagonistas & inibidores , Brometo de Vecurônio/antagonistas & inibidores , Adolescente , Adulto , Humanos , Pessoa de Meia-Idade , Junção Neuromuscular/efeitos dos fármacos , Junção Neuromuscular/fisiologia , Transmissão Sináptica/efeitos dos fármacos
15.
Anesth Analg ; 82(1): 139-42, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8712390

RESUMO

We studied the possible effects of repetitive (1-min interval) 50- and 100-Hz tetanic stimuli on 50-Hz and 100-Hz tetanic fade ratios (RF50HZ and RF100HZ). We also evaluated the sensitivity of the recorded responses to these two tests to assess residual neuromuscular block (isometric adductor pollicis mechanical activity), either during spontaneous recovery, or 15 min after neostigmine administration, in 22 adult anesthetized (thiopental, fentanyl, N2O/O2) patients receiving vecuronium. Two 50-Hz and two 100-Hz, 5-s duration, tetanic stimulations were randomly assessed at 1-min intervals: in a spontaneous (SPO) group (n = 11), when train-of-four (TOF) ratio spontaneously regained 0.7, and in a neostigmine (NEO) group (n = 11), 15 min after 40 micrograms/kg neostigmine was given intravenously at 25% return of control twitch tension. In the SPO group, when TOF ratio was 0.7, RF50HZ was 0.92 +/- 0.01 before and after subsequent tetanic stimulation, while RF100HZ was 0.48 +/- 0.05 and 0.47 +/- 0.05, respectively (not significant [NS]). In the NEO group, when TOF ratio was approximately 0.9, RF50HZ was 0.93 +/- 0.01 before and after subsequent tetanic stimulation, while RF100HZ was 0.80 +/- 0.02 and 0.78 +/- 0.02, respectively (NS). From patient to patient, both RF50HZ and RF100HZ were also identical. In conclusion, in patients receiving vecuronium, 1) 5-s, 50- and 100-Hz tetanic stimuli may be repeated without changes at 1-min intervals and, 2) in contrast to RF50HZ, recorded RF100HZ enables one to determine residual neuromuscular block during spontaneous recovery (P < 0.001) such as after neostigmine reversal (P < 0.05).


Assuntos
Estimulação Elétrica/métodos , Contração Isométrica/efeitos dos fármacos , Contração Isométrica/fisiologia , Fármacos Neuromusculares não Despolarizantes/farmacologia , Brometo de Vecurônio/farmacologia , Adolescente , Adulto , Atropina/farmacologia , Inibidores da Colinesterase/farmacologia , Estudos de Avaliação como Assunto , Humanos , Hipóxia/fisiopatologia , Pessoa de Meia-Idade , Neostigmina/farmacologia , Junção Neuromuscular/efeitos dos fármacos , Junção Neuromuscular/fisiologia , Sensibilidade e Especificidade , Transmissão Sináptica/efeitos dos fármacos , Transmissão Sináptica/fisiologia
16.
Anesth Analg ; 81(2): 385-8, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7618732

RESUMO

Eight morbidly obese patients (body mass index [BMI] = 46) were studied during general anesthesia and controlled mechanical ventilation. To evaluate the effect of large tidal volume ventilation on oxygenation and ventilation, the baseline 13 mL/kg tidal volume (VT) (calculated by the ideal body weight) was increased in 3 mL/kg volume increments to 22 mL/kg, while ventilatory rate (RR) and inspiratory time (TI) were kept constant. Each volume increment was maintained for 15 min. Gas exchange was assessed by measuring the arterial blood oxygen tensions, and calculating the indices of alveolar-arterial oxygen tension difference [P(A-a)O2] and arterial/alveolar oxygen tension ratio (a/A). Peak inspiratory airway pressure (Ppeak), end-inspiratory airway pressure (Pplateau), and compliance of the respiratory system (CRS) were recorded using the Capnomac Ultima (Datex, Helsinki, Finland) on-line respiratory monitor. Increasing tidal volumes to 22 mL/kg increased the recorded Ppeak (26.3 +/- 4.1 vs 37.9 +/- 3.2 cm H2O, P < 0.008), Pplateau (21.5 +/- 3.6 vs 27.7 +/- 4.3 cm H2O, P < 0.01), and CRS (39.8 +/- 7.7 vs 48.5 +/- 8.3 mL/cm H2O) significantly without improving arterial oxygen tension and resulted in severe hypocapnia. Since changes in arterial oxygenation were small and not statistically significant, mechanical ventilation of morbidly obese patients with large VTS seems to offer no advantage to smaller (13 mL/kg ideal body weight) VTS.


Assuntos
Anestesia Geral , Obesidade Mórbida/fisiopatologia , Consumo de Oxigênio , Respiração Artificial , Volume de Ventilação Pulmonar , Adulto , Peso Corporal , Volume de Reserva Expiratória , Feminino , Capacidade Residual Funcional , Humanos , Hipocapnia/etiologia , Inalação , Complacência Pulmonar , Masculino , Monitorização Intraoperatória , Obesidade Mórbida/sangue , Obesidade Mórbida/metabolismo , Oxigênio/sangue , Pressão , Troca Gasosa Pulmonar , Ventilação Pulmonar , Respiração , Relação Ventilação-Perfusão
17.
Br J Anaesth ; 74(1): 12-5, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7880697

RESUMO

We recorded adductor pollicis mechanical activity in response to low (0.1 and 2 Hz) and high (50 and 100 Hz) frequency stimulation 15 min after edrophonium 250, 500 and 1000 micrograms kg-1, given to antagonize vecuronium-induced block at 10, 25 and 50% pre-reversal twitch height. We studied 54 ASA class I and II anaesthetized (methohexitone, fentanyl, nitrous oxide) young adult patients allocated randomly to nine groups of six patients each. The greater sensitivity of train-of four (TOF) ratio and residual force after 100-Hz, 5-s tetanic stimulation (RF100) to residual deficit allowed discrimination more readily between the effects of edrophonium dose and pre-reversal twitch height (P < 0.001, two-way analysis of variance). The highest reversal scores (approximately 0.9 TOF ratio and 0.6 RF100) were obtained when edrophonium 500-1000 mg kg-1 was given at 50% twitch height (P < 0.05, Duncan's test).


Assuntos
Edrofônio/farmacologia , Bloqueio Nervoso , Junção Neuromuscular/efeitos dos fármacos , Estimulação Elétrica Nervosa Transcutânea , Brometo de Vecurônio/antagonistas & inibidores , Adolescente , Adulto , Relação Dose-Resposta a Droga , Humanos , Pessoa de Meia-Idade , Contração Muscular/efeitos dos fármacos , Contração Muscular/fisiologia , Junção Neuromuscular/fisiologia , Transmissão Sináptica
18.
Br J Anaesth ; 73(6): 791-4, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7880668

RESUMO

In 24 ASA I-II adults anaesthetized with thiopentone, fentanyl and nitrous oxide in oxygen, we studied neuromuscular transmission with isometric adductor pollicis monitoring. Patients received mivacurium 0.2 mg kg-1 followed by an infusion lasting at least 60 min and adjusted to maintain twitch height at 1-5%. After termination of the mivacurium infusion, when twitch height spontaneously regained 25% of its control value, the patients were allocated to two groups of 12 patients each. In group NEO patients received neostigmine 40 micrograms kg-1 and atropine 15 micrograms kg-1 and in group SPO neuromuscular transmission was allowed to recover spontaneously. Twitch height was measured every 10 s and train-of-four (TOF) (2 Hz) every 3 min. After 15 min, residual force after tetanic stimulation (50 and 100 Hz, 5-s duration (RF50HZ, RF100HZ), 1 min apart) were recorded sequentially. At 15 min, mean TOF ratio was greater in group NEO (0.94 (SEM 0.01)) than in group SPO (0.87 (0.02)) (P < 0.01). All patients in group NEO recovered to a TOF ratio greater than 0.7 after 6 min compared with 15 min in group SPO (P < 0.005). A TOF ratio greater than 0.9 was observed in all patients in group NEO compared with only six in group SPO (P < 0.025). Nevertheless, RF50HZ and RF100HZ did not differ significantly (0.92 (0.01) (group NEO), 0.91 (0.01) (group SPO) and 0.83 (0.02) (group NEO), 0.78 (0.03) (group SPO), respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Isoquinolinas , Neostigmina/administração & dosagem , Bloqueio Nervoso , Junção Neuromuscular/efeitos dos fármacos , Fármacos Neuromusculares não Despolarizantes , Adulto , Análise de Variância , Período de Recuperação da Anestesia , Procedimentos Cirúrgicos Eletivos , Fentanila , Humanos , Contração Isométrica , Perna (Membro)/cirurgia , Mivacúrio , Placa Motora , Neostigmina/farmacologia , Óxido Nitroso , Transmissão Sináptica , Tiopental
19.
J Clin Anesth ; 6(4): 297-302, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7946365

RESUMO

STUDY OBJECTIVE: To evaluate the predictive accuracy of midazolam during cardiac anesthesia so as to orient the selection of the most appropriate pharmacokinetic model for use in a computer-assisted continuous-infusion system. DESIGN: Retrospective analysis. SETTING: Operating room at a university hospital. PATIENTS: 66 consecutive middle-aged and elderly coronary patients scheduled for coronary artery bypass graft (CABG) surgery. INTERVENTIONS: Patients were anesthetized using a variable-rate infusion of alfentanil combined with midazolam in an attempt to achieve and maintain target concentrations of 100 ng/ml or 500 ng/ml. MEASUREMENTS AND MAIN RESULTS: A total of 323 arterial blood samples were taken, and serum midazolam concentrations were measured by high-performance liquid chromatography. Predicted midazolam concentrations were calculated using 3 selected data sets. Their bias, inaccuracy, and dispersion were assessed by determining the median performance error, the median absolute performance error (MDAPE), and the 10th and 90th percentiles. Two of the selected data sets of midazolam, with a clearance lower than 5 ml/kg/min, were very accurate (MDAPE less than 20%) in predicting low or high prebypass concentrations of midazolam in adult patients with good left ventricular function. CONCLUSIONS: Two of the 3 pharmacokinetic data sets of midazolam studied may be selected when using a computer-assisted infusion system in adult coronary patients.


Assuntos
Anestesia Intravenosa , Ponte de Artéria Coronária , Midazolam/administração & dosagem , Midazolam/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Alfentanil/administração & dosagem , Sistemas Computacionais , Feminino , Previsões , Humanos , Bombas de Infusão , Masculino , Midazolam/sangue , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...