Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mar Pollut Bull ; 98(1-2): 341-8, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26072050

RESUMO

This study analyzed the carapace distribution of Ca, Cd, Cr, Cu, Mg, Mn, Pb, Sb, U, V and Zn by GF-AAS and ICP-AES in one specimen of Caretta caretta from Mediterranean Sea. Calcium, Mg, Mn, Pb, U, Zn were mainly distributed in the central area while Cd, Cr, Cu, Sb, V in lateral areas. Cadmium, Cr, Mg, Mn, Sb, U and V were different between lateral areas. The different distribution may be related to several exposures during lifetime and/or the shell ossification during growth. Carapace may be a suitable matrix for metal biomonitoring, however, further studies are required to confirm these findings.


Assuntos
Exoesqueleto/química , Monitoramento Ambiental/métodos , Metais/farmacocinética , Tartarugas/metabolismo , Poluentes Químicos da Água/análise , Animais , Exposição Ambiental/análise , Mar Mediterrâneo , Metais/análise , Distribuição Tecidual , Poluentes Químicos da Água/farmacocinética
2.
Dermatology ; 226(3): 200-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23751225

RESUMO

BACKGROUND: Skin-lightening products are increasingly common in European cities. These products may contain substances that are banned under EU regulations as they can induce adverse effects, including cutaneous and systemic reactions (e.g., mercury, hydroquinone and topical corticosteroids). OBJECTIVES: To assess the knowledge, attitudes and practices of women regarding skin-lightening products and to quantify the potentially harmful substances in the products used. METHODS: We performed a cross-sectional study among 82 non-Italian women visiting an outpatient facility in Rome, Italy. The women completed a questionnaire on product use, side effects and risk awareness. We performed patch tests among a subgroup of 48 women who presented with contact dermatitis. We also quantified the allergenic and toxic substances in the 14 products reported, using dynamic reaction cell inductively coupled plasma mass spectrometry for metals and high-performance liquid chromatography for hydroquinone and topical corticosteroids. RESULTS: Out of the 82 women, 33 used skin-lightening products; about one fourth of these women were aware of potential risks. Three cosmetic creams and two soaps contained high concentrations of metals (Cr, Ni and Pb); hydroquinone was found in three creams and one oil. The only topical corticosteroid detected was dexamethasone, in one product. More than half of the women in the clinical evaluation had irritant contact dermatitis (i.e., negative response to patch test). CONCLUSIONS: Among immigrant women in Rome, the use of skin-lightening products seems to be fairly common, and some of these products contain potentially hazardous substances. Consumers must be informed of the potential risks, and EU regulations must be more strictly enforced.


Assuntos
Emigrantes e Imigrantes , Conhecimentos, Atitudes e Prática em Saúde , Preparações Clareadoras de Pele/química , Preparações Clareadoras de Pele/uso terapêutico , Adolescente , Adulto , África/etnologia , Ásia/etnologia , Estudos Transversais , Dermatite Irritante/diagnóstico , Dexametasona/análise , Feminino , Conhecimentos, Atitudes e Prática em Saúde/etnologia , Humanos , Hidroquinonas/análise , Metais/análise , Pessoa de Meia-Idade , Testes do Emplastro , Projetos Piloto , Cidade de Roma , Preparações Clareadoras de Pele/efeitos adversos , América do Sul/etnologia , Inquéritos e Questionários , Adulto Jovem
3.
Mar Pollut Bull ; 62(8): 1606-15, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21700299

RESUMO

Chemical elements and persistent organic pollutants (POPs) are globally present in aquatic systems and their potential transfer to loggerhead marine turtles (Caretta caretta) has become a serious threat for their health status. The environmental fate of these xenobiotics may be traced by the analysis of turtles' tissues and blood. Generally, loggerhead turtles exhibited a higher metal load than other turtle species, this could be explained by differences in diet habits being food the main source of exposure. Literature shows that muscle, liver and kidney are most considered for the quantification of chemical elements, while, organic compounds are typically investigated in liver and fat. This paper is an overview of the international studies carried out on the quantification of chemical elements, polychlorinated biphenyls (PCBs), organochlorines (OCs) and perfluorinated compounds (PFCs), in tissues, organs and fluids of C. caretta from the Mediterranean Sea, the Atlantic and the Pacific Oceans.


Assuntos
Monitoramento Ambiental , Compostos Orgânicos/análise , Plásticos/análise , Tartarugas/metabolismo , Poluentes Químicos da Água/análise , Animais , Oceanos e Mares , Compostos Orgânicos/farmacocinética , Plásticos/farmacocinética , Distribuição Tecidual , Poluentes Químicos da Água/farmacocinética
4.
Anal Chim Acta ; 624(1): 59-67, 2008 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-18706310

RESUMO

With Regulation No. 1881/2006 the European Union fixed a maximum level for lead in milk. Consequently, there is the need to determine very low concentration of elements that may be present in milk in trace and ultratrace levels. Quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) combined with dynamic reaction cell (DRC) has been widely employed in order to reach very low concentration, requested for this product. Furthermore, the DRC technology can help in removing polyatomic and argon-based interferences. In the present study, a method for the determination of arsenic, cadmium, chromium and lead in bovine milk was validated according to the EU common standards by means of DRC-ICP-MS. The main parameters evaluated in the validation were: recovery, repeatability and within-laboratory reproducibility, detection and quantification limits, linearity range and measurement uncertainty. Additionally, stability studies of the analyte in solution and ruggedness studies were carried out. The results obtained for limit of detection (LoD) and limit of quantification (LoQ) in microg kg(-1) were respectively: As, 3.1 and 9.5; Cd, 0.08 and 0.24; Cr, 0.229 and 0.693; Pb, 0.5 and 1.5. While for the recovery: As, 91%; Cd 96%; Cr 99%; Pb, 95%. As for the repeatability: As, 7%; Cd, 3%; Cr, 6%; Pb, 4%.


Assuntos
Arsênio/análise , Cádmio/análise , Cromo/análise , Contaminação de Alimentos/análise , Chumbo/análise , Leite/química , Animais , Calibragem , União Europeia , Humanos , Fórmulas Infantis/química , Espectrometria de Massas/métodos , Leite Humano/química , Reprodutibilidade dos Testes
5.
Anal Chim Acta ; 597(2): 195-202, 2007 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-17683730

RESUMO

Depleted uranium (DU) is a by-product of the uranium enrichment process for nuclear fuel. According to the Commission Decision 2002/657/EC, a confirmatory method for the quantification of DU in freeze-dried fish was developed by isotope ratio dynamic reaction cell inductively coupled plasma-mass spectrometry (IR-DRC-ICP-MS). A preliminary study was performed to determine the following parameters: instrumental detection limit (IDL), isotopic ratio measurement limit (IRML), percentage of DU (P(DU)) in presence of natural uranium (NU) and limit of quantification (LoQ(DU)). The analyses were carried out by means of IR-DRC-ICP-MS. Ammonia was the reaction gas used for the dynamic reaction cell. In addition, a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) was employed to calculate the within-laboratory reproducibility. For the confirmatory method the following parameters were determined: (a) trueness; (b) precision; (c) critical concentrations alpha and beta (CC(alpha), CC(beta)); (d) specificity; (e) stability. Trueness was assessed by using the recovery tests. The recovery and within-laboratory reproducibility were determined by fortifying the blank digested solution of dogfish tissue: six aliquots were fortified at 1, 1.5 and 2 times the LOQ(DU) with 25.0, 37.5 and 50.0 ng L(-1) or 4.16, 6.24, 8.32 microg kg(-1) with a recovery of -8.2, +9.5 and +9.6%, respectively and a within-laboratory reproducibility (three analytical run) of 15.5, 8.0 and 11.0%, respectively. The results for the decision limit and the detection capability were: CC(alpha) = 11.69 ng L(-1) and CC(beta) = 19.8 ng L(-1). The digested solutions resulted to be stable during testing time (60 days) and the method can be considered highly specific as well.

6.
Anal Chim Acta ; 573-574: 432-8, 2006 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-17723557

RESUMO

An inductively coupled plasma mass spectrometer (ICP-MS), equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulizing system (Apex-ACM) to reduce the oxide formation, was used in the determination of Al, Co, Cr, Mn, Ni and Se in serum samples. The effect of the operating conditions of the DRC system was studied to get the best signal-to-background (S/B) ratio. The potentially interfering molecular ions at the masses m/z27Al, 59Co, 52Cr, 55Mn, 60Ni and 78Se, were significantly reduced in intensity by using NH3 and H2, as the reaction cell gases in the DRC, while a proper Dynamic Bandpass Tuning parameter q (RPq) value was optimized. The detection limits for 27Al, 59Co, 52Cr, 55Mn, 60Ni and 78Se, estimated with 3-sigma method, resulted to be 0.14, 0.003, 0.002, 0.01, 0.01 and 1.8 microg L(-1), respectively. This analytical method was developed on both a human serum certified reference material and a lyophilized animal serum produced and proposed in an intercomparison study. The results obtained for the reference samples agreed satisfactorily with the certified values. Precision (expressed as CV%) between sample replicates was better than 10% for elements determination, with the only exception of aluminium (14%).

7.
Anal Chim Acta ; 579(2): 202-8, 2006 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-17723744

RESUMO

A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulization system (APEX-IR) was employed to determine 17 elements (Al, As, Ba, Cd, Co, Cr, Li, Mn, Mo, Ni, Pb, Sb, Se, Sn, Sr, V, and Zr) in blood samples. Ammonia (for Al, Cr, Mn, and V) and O2 (for As and Se) were used as reacting gases. Selection of the best flow rate of the gases and optimization of the quadrupole dynamic bandpass tuning parameter (RPq) were carried out, using digested blood diluted 1+9 with deionized water and spiked with 1 microg L(-1) of Al, Cr, Mn, V and 5 microgL(-1) of As and Se. Detection limits were determined in digested blood using the 3sigma criterion. The desolvating system allowed a sufficient sensitivity to be achieved to determine elements at levels of ng L(-1) without detriment of signal stability. The accuracy of the method was tested with the whole blood certified reference material (CRM), certified for Al, As, Cd, Co, Cr, Mn, Mo, Ni, Pb, Sb, Se, and V, and with indicative values for Ba, Li, Sn, Sr, and Zr. The addition calibration approach was chosen for analysis. In order to confirm the DRC data, samples were also analyzed by means of sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), operating in medium (m/Deltam=4000) and high (m/Deltam=10,000) resolution mode and achieving a good agreement between the two techniques.

8.
J AOAC Int ; 84(6): 1972-5, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11767170

RESUMO

The feasibility of producing and certifying new certified reference materials (CRMs) for trace elements in honey was investigated. Preliminary steps for preparation of candidate materials are performed at the Institute for Reference Materials and Measurements, Joint Research Centre of the European Commission (EC-JRC-IRMM). Two different types of honey, Acacia and Eucalyptus, were tested for determination of 10 trace elements. To each type of honey was added a given amount of high purity deionized water to obtain aqueous solutions with an acceptable degree of homogeneity which would require only minimal manipulation before analysis. Average values obtained for the trace elements by means of inductively coupled plasma-based techniques were as follows (in microg/ kg +/- SD): Acacia honey, As, 1.10+/-0.20; Cd, 0.328+/-0.035; Cr, 1.90+/-0.22; Cu, 67.0+/-5; Fe, 215+/-30; Hg, < 0.75; Mn, 82.1+/-6.2; Ni, 21.0 3.0; Pb, 2.30+/-0.25; Se, 9.10+/-1.2; Zn, 167+/-22; Eucalyptus honey, As, 5.99+/-0.10; Cd, 0.592+/-0.074; Cr, 1.50+/-0.07; Cu, 219 24; Fe, 1008+/-114; Hg, <0.75; Mn, 1009+/-51; Ni, 11.3+/-1.5; Pb, 5.00+/-0.40; Se, 5.60+/-0.91; Zn, 791+/-91. When these 2 pilot materials are ready, the certification project will be launched in full compliance with current rules set by EC-JRC-IRMM. If the project is successful, the new CRMs will be put primarily at the disposal of the National Reference Laboratories for trace elements.


Assuntos
Análise de Alimentos/métodos , Análise de Alimentos/normas , Mel/análise , Mel/normas , Oligoelementos/análise , Oligoelementos/normas , Itália , Espectrometria de Massas/métodos , Projetos Piloto , Padrões de Referência , Espectrofotometria Atômica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...