A qQNMR methodology using nitrogen-14 as the quadrupolar nucleus of choice has been introduced for the first time as a robust and validated method to determine and quantify L-carnitine in food supplements. The quantification has been carried out by the alternative use of a calibration curve or by addition of ammonium chloride as internal standard. The method was validated at seven concentration levels in the range of 5.58-99.26 mM, affording intra- and inter day accuracies lower than 6.84% (expressed in CV), robustness towards temperature and recycle delay, limit of detection (LOD) of 2.48 mM, limit of quantification (LOQ) of 5.58 mM and remarkably with absence of matrix effect.