Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 17(3-4): 203-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12455737

RESUMO

OBJECTIVE: There is no commonly accepted in vivo calibration method for pulse oximeters available up to now. On the basis of a prototype device for the calibration of pulse oximeters which was introduced recently, a second approach based on the same concept was tackled in order to design a reliable method for standardized calibration of pulse oximeters. METHODS: An extensive clinical database of time-resolved optical transmission spectra of patient fingers is used to simulate the behavior of patients. A device which is capable of playing back these spectroscopic data to pulse oximeters, and a database where the oxygen status measured with the reference method (Co-Oximetry) is stored, are the main parts of the concept. The playback device has an artificial finger as interface to the pulse oximeters and serves to collect light from the pulse oximeter for analysis and to playback simulated light to the pulse oximeter. The light intensity emitted by two LEDs which illuminates the pulse oximeter detector is controlled via a computer in such a way that it is the same as if the pulse oximeter light had passed the finger. The pulse oximeter display during the data playback can thus be compared to the true SaO2 of the patient. The device is tested with 4 pulse oximeters based on 100 patient spectra. RESULTS: For the four pulse oximeters used in this investigation, an Agilent Technologies CMS monitor (formerly Hewlett-Packard), an Ivy 2000 with Masimo Set technology and Nellcor N-3000 and N-395, there is good correlation between SPO2 and SaO2, and mean and standard deviation of in vivo SpO2-SaO2 and playback SpO2-SaO2 are in good agreement. For two instruments, Nellcor N3000 and Agilent CMS Monitor, a quantitative comparison between the in vivo and in vitro SpO, results was derived. A mean of the deviation playback vs. in vivo SpO2 is less than 0.5% SpO2. The error limits are comparable with the calibration error of the conventional calibration routine. The device is also capable of data playback even in situations with rapid desaturation changes, as displayed in Figure 2. For the other tested pulse oximeters the results are comparable. CONCLUSIONS: Compared to the first prototype the current version is simpler and less expensive in production. Many of previously existing problems are solved and the applicability to a large variety of pulse oximeters and sensors is given. The novel concept for the calibration of pulse oximeters is a tool for assessing the performance of pulse oximeters.


Assuntos
Oximetria/instrumentação , Calibragem , Desenho de Equipamento , Humanos
2.
J Toxicol Clin Toxicol ; 35(1): 35-40, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9022650

RESUMO

BACKGROUND: MDA is the abbreviation for methylene dianiline (p,p' diaminodiphenylmethane; 4,4'-methylenedianiline; CAS 101-77-9); and for methylendioxyamphetamine (MDMA, N, alpha-dimethyl-1,3-benzodioxole-5-ethanamine; CAS 42542-10-9). While the former is used for the production of polyurethane foams, the latter is a psychometric drug, which is becoming increasingly popular in the techno scene. METHODS: We report six participants of a technoparty (1 female, 5 males, ages 17-25) who were admitted to the hospital with severe colicky abdominal pain and subsequently developed symptoms of hepatotoxicity. They had ingested an alcoholic beverage that had been spiked with a powdery substance they dubbed MDA. RESULTS: All patients showed similar clinical symptoms, with an identical time course. Acute jaundice developed within 2 days after ingestion. Enzymes indicating cholestasis increased steadily over 7 days and reached peak values of 800 U/L (AP) and 380 U/L (GGT), whereas transaminases remained moderately elevated. Between days 5 and 7, all patients became febrile for one day, their body temperatures rising up to 40 degrees C. There was no evidence for hemolysis or an infectious hepatitis. Toxicological analysis revealed the presence of p,p'-diaminodiphenylmethane (4,4'-methylenedianiline) at a concentration of 130 mg/L in one of two urine extracts examined. CONCLUSIONS: The analytical data indicate that the participants of the technoparty assumed the aniline-derivative, the cause of Epping Jaundice, was methylendioxyamphetamine because the same abbreviation, MDA, is used for both compounds. An overview of the acute liver toxicity of aniline derivatives is given and the possibility of amphetamine-induced liver damage is discussed.


Assuntos
Compostos de Anilina/toxicidade , Carcinógenos/toxicidade , Hepatopatias/etiologia , 3,4-Metilenodioxianfetamina/intoxicação , Adolescente , Adulto , Compostos de Anilina/sangue , Compostos de Anilina/urina , Doença Hepática Induzida por Substâncias e Drogas , Diagnóstico Diferencial , Feminino , Humanos , Testes de Função Hepática , Masculino , Prontuários Médicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...