Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Aging Phys Act ; 30(2): 225-236, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34438366

RESUMO

The authors investigated the agreement between StepWatch3™ (SW3) and ActiGraph™ wGT3X+ monitors for measuring step-based metrics in patients with peripheral artery disease and older adults. In 23 patients with peripheral artery disease and 38 older participants, the authors compared the metrics obtained during an outdoor (400-m track) walking session (step count) and a 7-day free-living period (step count and 60/30/5/1-min maximal or peak step accumulation) using the SW3 (ankle) and the wGT3X+ (hip) with the low-frequency extension filter enabled (wGT3X+/LFE) or not (wGT3X+/N). During outdoor walking session, agreement was high, particularly for wGT3X+/LFE: correlations ≥.98, median absolute percentage errors <1%, and significant equivalence using a ± 15% equivalence zone or narrower. In free living, no wGT3X+ method was equivalent to SW3 for step count. The wGT3X+/LFE was equivalent to SW3 regarding all step accumulation metrics using a ± 20% equivalence zone or narrower, with median absolute percentage errors <11%. The wGT3X+/LFE method is the best option for comparisons with SW3 in peripheral artery disease and older adults.


Assuntos
Benchmarking , Doença Arterial Periférica , Actigrafia , Idoso , Humanos , Doença Arterial Periférica/diagnóstico , Caminhada
2.
Sensors (Basel) ; 21(9)2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-34064381

RESUMO

We aimed at showing how Global Positioning System (GPS) along with a previously validated speed processing methodology could be used to measure outdoor walking capacities in people with multiple sclerosis (MS). We also deal with methodological issues that may occur when conducting such measurements, and explore to what extent GPS-measured outdoor walking capacities (maximal walking distance [MWDGPS] and usual walking speed) could be related to traditional functional outcomes (6-min total walking distance) in people with MS. Eighteen people with MS, with an Expanded Disability Status Scale score ≤6, completed a 6-min walking test and an outdoor walking session (60 min maximum) at usual pace during which participants were wearing a DG100 GPS receiver and could perform several walking bouts. Among the 12 participants with valid data (i.e., who correctly completed the outdoor session with no spurious GPS signals that could prevent the detection of the occurrence of a walking/stopping bout), the median (90% confidence interval, CI) outdoor walking speed was 2.52 km/h (2.17; 2.93). Ten participants (83% (56; 97)) had ≥1 stop during the session. Among these participants, the median of MWDGPS was 410 m (226; 1350), and 40% (15; 70) did not reach their MWDGPS during the first walking bout. Spearman correlations of MWDGPS and walking speed with 6-min total walking distance were, respectively, 0.19 (-0.41; 0.95) and 0.66 (0.30; 1.00). Further work is required to provide guidance about GPS assessment in people with MS.


Assuntos
Esclerose Múltipla , Caminhada , Sistemas de Informação Geográfica , Humanos , Esclerose Múltipla/diagnóstico , Velocidade de Caminhada
3.
J Appl Physiol (1985) ; 131(1): 207-219, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33982591

RESUMO

The objective of the study was to investigate the effect of recovery time on walking capacity (WC) throughout repeated maximal walking bouts in symptomatic lower-extremity peripheral artery disease (PAD). The effect of recovery time on WC (maximal walking time) was determined in 21 participants with PAD in three experimental conditions [recovery time from 0.5 to 9.5 min + a self-selected recovery time (SSRT)]: 1) 11 repeated sequences of two treadmill walking bouts (TW-ISO); 2) a single sequence of seven treadmill walking bouts (TW-CONS); 3) a single sequence of seven outdoor walking bouts (OW-CONS). Exercise transcutaneous oxygen pressure changes were continuously recorded as an indirect measure of ischemia. An individual recovery time (IRT) beyond which WC did not substantially increased was determined in participants with a logarithmic fit. At the group level, mixed models showed a significant effect (P < 0.001) of recovery time on WC restoration. At the participant level, strong logarithmic relationships were found (median significant R2 ≥ 0.78). The median SSRT corresponded to a median work-to-rest ratio >1:1 (i.e., a lower recovery time in view of the corresponding previous walking time) and was related to unrecovered ischemia and a WC restoration level of <80%. A median work-to-rest ratio of ≤1:2 allowed full recovery of ischemia and full restoration of WC. The IRT ratio was between 1:1 and 1:2 and corresponded to the start of recovery from ischemia. Recovery time affects the restoration level of WC during repeated maximal walking bouts in symptomatic PAD. Meaningful variations in WC restoration were related to specific levels of work-to-rest ratios.NEW & NOTEWORTHY This study demonstrated that there is a significant and mostly logarithmic effect of recovery time on walking capacity in people with symptomatic PAD. This study revealed that a median work-to-rest ratio >1:1 leads to the resumption of walking with unrecovered ischemia and precludes the restoration of full walking capacity, whereas a work-to-rest ratio ≤1:2 allowed walking capacity to fully be restored.


Assuntos
Doença Arterial Periférica , Caminhada , Teste de Esforço , Tolerância ao Exercício , Humanos , Claudicação Intermitente , Extremidade Inferior
4.
Med Sci Sports Exerc ; 53(6): 1303-1314, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33731660

RESUMO

PURPOSE: This study aimed to determine and compare the accuracy of different activity monitors in assessing intermittent outdoor walking in both healthy and clinical populations through the development and validation of processing methodologies. METHODS: In study 1, an automated algorithm was implemented and tested for the detection of short (≤1 min) walking and stopping bouts during prescribed walking protocols performed by healthy subjects in environments with low and high levels of obstruction. The following parameters obtained from activity monitors were tested, with different recording epochs0.1s/0.033s/1s/3s/10s and wearing locationsscapula/hip/wrist/ankle: GlobalSat DG100 (GS) and Qstarz BT-Q1000XT/-Q1000eX (QS) speed; ActiGraph wGT3X+ (AG) vector magnitude (VM) raw data, VM counts, and steps; and StepWatch3 (SW) steps. Furthermore, linear mixed models were developed to estimate walking speeds and distances from the monitors parameters. Study 2 validated the performance of the activity monitors and processing methodologies in a clinical population showing profile of intermittent walking due to functional limitations during outdoor walking sessions. RESULTS: In study 1, GS1s, scapula, QS1s, scapula/wrist speed, and AG0.033s, hip VM raw data provided the highest bout detection rates (>96.7%) and the lowest root mean square errors in speed (≤0.4 km·h-1) and distance (<18 m) estimation. Using SW3s, ankle steps, the root mean square error for walking/stopping duration estimation reached 13.6 min using proprietary software and 0.98 min using our algorithm (total recording duration, 282 min). In study 2, using AG0.033s, hip VM raw data, the bout detection rate (95% confidence interval) reached 100% (99%-100%), and the mean (SD) absolute percentage errors in speed and distance estimation were 9% (6.6%) and 12.5% (7.9%), respectively. CONCLUSIONS: GPS receivers and AG demonstrated high performance in assessing intermittent outdoor walking in both healthy and clinical populations.


Assuntos
Acelerometria/instrumentação , Monitores de Aptidão Física , Sistemas de Informação Geográfica/instrumentação , Caminhada/fisiologia , Idoso , Algoritmos , Humanos , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Velocidade de Caminhada/fisiologia , Adulto Jovem
6.
Scand J Med Sci Sports ; 29(11): 1813-1826, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31271680

RESUMO

PURPOSE: To develop, assess the feasibility of, and determine the clinical validity of an event-based analysis method using wearable monitors to quantify walking pain manifestations (WPMs) and stops induced by walking pain (SIWPs) during daily life walking in people with peripheral artery disease (PAD). METHODS: The following two conditions were studied: a standardized outdoor walking session (OWS) and a seven-day free-living measurement (FLM) period. The PAD participants (n = 23) wore an accelerometer and a watch. They were asked to press the event marker button on the watch to indicate events related to WPMs and SIWPs. To assess the clinical validity of the method, the computed pain-free walking time (PFWT) and maximal walking time (MWT) were compared with the PFWT and MWT assessed using standard treadmill walking protocols, respectively. RESULTS: Following OWSs, the PFWT[OWS] and MWT[OWS] were significantly correlated with the PFWT[Strandness] (r = .955, P < .001) and MWT[Strandness] (r = .821, P < .001), respectively. During the FLM, PAD participants experienced only 2 WPMs/day and 1 SIWP/day, although severely limited on the treadmill and during the OWS. The average WPMs/day were moderately correlated with the PFWT[Strandness] (r = -.54, P = .016). The PFWT[FLM] was on average 12 times longer than the PFWT[Strandness] . Interestingly, the intensity of the walking bouts as assessed by the accelerometer counts during the FLM was significantly lower than that during the OWS (45 ± 15 vs 66 ± 20 counts/s, P < .001). CONCLUSION: This new method offers opportunities for studies investigating the experience of living with PAD and the assessment of daily life walking capacity for both diagnostic and therapeutic purposes.


Assuntos
Tolerância ao Exercício , Dor/etiologia , Doença Arterial Periférica/complicações , Caminhada , Dispositivos Eletrônicos Vestíveis , Acelerometria , Idoso , Estudos Transversais , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Physiol Meas ; 37(10): 1741-1756, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27653453

RESUMO

The aim of this study was to assess, for the first time, the accuracy of a low-cost global positioning system (GPS) receiver for estimating grade during outdoor walking. Thirty subjects completed outdoor walks (2.0, 3.5 and 5.0 km · h-1) in three randomized conditions: 1/level walking on a 0.0% grade; 2/graded (uphill and downhill) walking on a 3.4% grade; and 3/on a 10.4% grade. Subjects were equipped with a GPS receiver (DG100, GlobalSat Technology Corp., Taiwan; ~US$75). The GPS receiver was set to record at 1 Hz and its antenna was placed on the right shoulder. Grade was calculated from GPS speed and altitude data (grade = altitude variation/travelled distance × 100). Two methods were used for the grade calculation: one using uncorrected altitude data given by the GPS receiver and another one using corrected altitude data obtained using map projection software (CartoExploreur, version 3.11.0, build 2.6.6.22, Bayo Ltd, Appoigny, France, ~US$35). Linear regression of GPS-estimated versus actual grade with R 2 coefficients, bias with 95% limits of agreement (±95% LoA), and typical error of the estimate with 95% confidence interval (TEE (95% CI)) were computed to assess the accuracy of the GPS receiver. 444 walking periods were performed. Using uncorrected altitude data, we obtained: R 2 = 0.88 (p < 0.001), bias = 0.0 ± 6.6%, TEE between 1.9 (1.7-2.2)% and 4.2 (3.6-4.9)% according to the grade level. Using corrected altitude data, we obtained: R 2 = 0.98 (p < 0.001), bias = 0.2 ± 1.9%, TEE between 0.2 (0.2-0.3)% and 1.0 (0.9-1.2)% according to the grade level. The low-cost GPS receiver used was weakly accurate for estimating grade during outdoor walking when using uncorrected altitude data. However, the accuracy was greatly improved when using corrected altitude data. This study supports the potential interest of using GPS for estimating energy expenditure during outdoor walking.

10.
J Appl Physiol (1985) ; 121(2): 577-88, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27402559

RESUMO

The objective of this study was to assess the accuracy of using speed and grade data obtained from a low-cost global positioning system (GPS) receiver to estimate metabolic rate (MR) during level and uphill outdoor walking. Thirty young, healthy adults performed randomized outdoor walking for 6-min periods at 2.0, 3.5, and 5.0 km/h and on three different grades: 1) level walking, 2) uphill walking on a 3.7% mean grade, and 3) uphill walking on a 10.8% mean grade. The reference MR [metabolic equivalents (METs) and oxygen uptake (V̇o2)] values were obtained using a portable metabolic system. The speed and grade were obtained using a low-cost GPS receiver (1-Hz recording). The GPS grade (Δ altitude/distance walked) was calculated using both uncorrected GPS altitude data and GPS altitude data corrected with map projection software. The accuracy of predictions using reference speed and grade (actual[SPEED/GRADE]) data was high [R(2) = 0.85, root-mean-square error (RMSE) = 0.68 MET]. The accuracy decreased when GPS speed and uncorrected grade (GPS[UNCORRECTED]) data were used, although it remained substantial (R(2) = 0.66, RMSE = 1.00 MET). The accuracy was greatly improved when the GPS speed and corrected grade (GPS[CORRECTED]) data were used (R(2) = 0.82, RMSE = 0.79 MET). Published predictive equations for walking MR were also cross-validated using actual or GPS speed and grade data when appropriate. The prediction accuracy was very close when either actual[SPEED/GRADE] values or GPS[CORRECTED] values (for level and uphill combined) or GPS speed values (for level walking only) were used. These results offer promising research and clinical applications related to the assessment of energy expenditure during free-living walking.


Assuntos
Actigrafia/métodos , Metabolismo Energético/fisiologia , Sistemas de Informação Geográfica , Modelos Biológicos , Consumo de Oxigênio/fisiologia , Esforço Físico/fisiologia , Caminhada/fisiologia , Adulto , Algoritmos , Simulação por Computador , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Vasa ; 45(1): 37-41, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26986708

RESUMO

BACKGROUND: Ankle-brachial index (ABI) at rest is the main clinical tool to diagnose the presence of lower extremity peripheral artery disease (PAD). The method for ABI procedure (i.e., measurement, calculation and interpretation) is standardised and guidelines were published in 2012. This study sought to: i) assess knowledge about the three major steps of the ABI procedure (i.e., measurement, calculation and interpretation) among residents from different medical schools, ii) compare the ABI knowledge of experienced residents (i.e., who have already performed ABI procedure more than 20 times) with the knowledge of inexperienced residents, and iii) describe the most common errors by residents. METHODS: Residents from six medical schools were invited to complete a questionnaire about the ABI procedure. RESULTS: Sixty-eight residents completed the questionnaire. None of them knew how to perform the entire ABI procedure. Overall, 22%, 13% and 41% of residents correctly answered questions about ABI measurement, ABI calculation and ABI interpretation, respectively. Score comparisons underlined the fact that experienced residents (n = 26) answered ABI measurement questions to a significantly better level and had a significantly higher total score than inexperienced residents (n = 42) (P = 0.0485 and P = 0.0332, respectively). Errors were similar for most of the residents. CONCLUSIONS: Our study confirms that experienced residents have significantly better ABI procedure knowledge than inexperienced residents. However, none of them are able to perform the entire ABI procedure without any mistake with regard to current guidelines. It is important that training be given to residents in medical schools in order to improve their ABI procedure knowledge.


Assuntos
Índice Tornozelo-Braço , Cardiologia/educação , Competência Clínica , Educação de Pós-Graduação em Medicina , Conhecimentos, Atitudes e Prática em Saúde , Internato e Residência , Doença Arterial Periférica/diagnóstico , França , Humanos , Doença Arterial Periférica/fisiopatologia , Padrões de Prática Médica , Valor Preditivo dos Testes , Inquéritos e Questionários
12.
Eur J Appl Physiol ; 113(6): 1373-83, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23229881

RESUMO

The aim of this longitudinal study was to compare two recovery modes (active vs. passive) during a seven-week high-intensity interval training program (SWHITP) aimed to improve maximal oxygen uptake ([Formula: see text]), maximal aerobic velocity (MAV), time to exhaustion (t lim) and time spent at a high percentage of [Formula: see text], i.e., above 90 % (t90 [Formula: see text]) and 95 % (t95 [Formula: see text]) of [Formula: see text]. Twenty-four adults were randomly assigned to a control group that did not train (CG, n = 6) and two training groups: intermittent exercise (30 s exercise/30 s recovery) with active (IEA, n = 9) or passive recovery (IEP, n = 9). Before and after seven weeks with (IEA and IEP) or without (CG) high-intensity interval training (HIT) program, all subjects performed a maximal graded test to determine their [Formula: see text] and MAV. Subsequently only the subjects of IEA and IEP groups carried out an intermittent exercise test consisting of repeating as long as possible 30 s intensive runs at 105 % of MAV alternating with 30 s active recovery at 50 % of MAV (IEA) or 30 s passive recovery (IEP). Within IEA and IEP, mean t lim and MAV significantly increased between the onset and the end of the SWHITP and no significant difference was found in t90 VO2max and t95 VO2max. Furthermore, before and after the SWHITP, passive recovery allowed a longer t lim for a similar time spent at a high percentage of VO2max. Finally, within IEA, but not in IEP, mean VO2max increased significantly between the onset and the end of the SWHITP both in absolute (p < 0.01) and relative values (p < 0.05). In conclusion, our results showed a significant increase in VO2max after a SWHITP with active recovery in spite of the fact that t lim was significantly longer (more than twice longer) with respect to passive recovery.


Assuntos
Desempenho Atlético/fisiologia , Corrida/fisiologia , Limiar Anaeróbio , Estudos de Casos e Controles , Tolerância ao Exercício , Humanos , Estudos Longitudinais , Masculino , Oxigênio/sangue , Distribuição Aleatória , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...