Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 38(17): 2210-2218, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28543614

RESUMO

HbA1c is used for monitoring diabetic balance. In this paper we report an assessment of the analytical performances of Capillarys 2 Flex Piercing (C2FP) for HbA1c measurement using CE (Capillary Electrophoresis). CLSI (Clinical and Laboratory Standard Institute) protocols are used for the evaluation of apparatus performances: precision, linearity, method comparison, trueness and common interferences. HbA1c CVs average in intra-assay was 1.6% between run imprecision CV ranged from 0.1 to 1.8%. The linearity was demonstrated between 4.7 and 15.0%. The comparison study revealed that Bland Altman plot mean difference was equal to -0.03 (CI 95% (-0.05 to -0.0003)) and Passing-Bablok regression intercept was -0.05, CI95%(-0.13 -  -0.05); slope: 1.00, CI95%[1.00-1.01]. A strong correlation (r > 0.99) was proved. No significant effects of hemoglobin variants were seen with CE on HbA1c measurement. No problem related to sample-to-sample carry over was noted. No interferences of LA1c and cHb were observed. CE allowed quantification of HbA1c even at low level of total hemoglobin (40 g/L) in contrast to HPLC. Furthermore, this analyzer offered the opportunity of quantifying the HbA2 simultaneously with HbA1c . This evaluation showed that C2FP is a convenient system for the control of diabetes and the detection of hemoglobinopathies.


Assuntos
Eletroforese Capilar/métodos , Eletroforese Capilar/normas , Hemoglobinas Glicadas/análise , Diabetes Mellitus/sangue , Diabetes Mellitus/metabolismo , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Tunísia
2.
Ann Biol Clin (Paris) ; 74(2): 219-26, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27029726

RESUMO

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy. More than 200 mutations in the G6PD gene have been described. In Tunisia, the A-African and the B-Mediterranean mutations predominate the mutational spectrum. The purpose of this study was to apply the amplification refractory mutation system (ARMS-PCR) to the identification of Gd A+, Gd A- and Gd B- variants in a cohort of deficient individuals and to establish a phenotype/genotype association. 90 subjects were screened for enzymatic deficiency by spectrophotometric assay. The molecular analyses were performed in a group of 50 unrelated patients. Of the 54 altered chromosomes examined, 60% had the Gd A- mutation, 18% showed the Gd B- mutation and in 20% of cases, no mutations have been identified. The ARMS-PCR showed complete concordance with the endonuclease cleavage reference method and agreed perfectly with previous Tunisian studies where Gd A- and Gd B- were the most encountered. Also, similarities in spectrum mutations with North African and Mediterranean countries suggest gene migration from Africa to Europe through Spain. In conclusion, ARMS has been introduced in this study for common G6PD alleles identification in Tunisia. It gives some advantages compared to the traditional endonuclease digestion method since it is more convenient and timesaving and also offers the possibility to be applied in mass screening surveys.


Assuntos
Análise Mutacional de DNA/métodos , Estudos de Associação Genética/métodos , Deficiência de Glucosefosfato Desidrogenase/genética , Glucosefosfato Desidrogenase/genética , Mutação de Sentido Incorreto , Reação em Cadeia da Polimerase/métodos , Adolescente , Adulto , Substituição de Aminoácidos , Criança , Pré-Escolar , Feminino , Frequência do Gene , Deficiência de Glucosefosfato Desidrogenase/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Tunísia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...