Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
AJNR Am J Neuroradiol ; 44(4): 441-446, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36958799

RESUMO

BACKGROUND AND PURPOSE: Mechanical thrombectomy appears to be a promising option for distal medium-vessel occlusions, for which intravenous thrombolysis is effective but may be insufficient when used alone. This study aimed to determine the optimal technique for these distal mechanical thrombectomies using the human placenta model. MATERIALS AND METHODS: Twenty-four procedures were performed, allowing comparison of direct aspiration (n = 12) versus the combined technique (n = 12). Two positions of the aspiration catheter were tested for each of these techniques: in direct contact with the clot and at a distance from it (5-10 mm). Two types of clots were tested: red blood cell-rich clots and fibrin-rich clots. First-pass recanalization and induced arterial collapse and traction were assessed. RESULTS: The first-pass recanalization was less frequent for direct aspiration than for the combined technique, without reaching statistical significance (41.7% versus 75.0%, P = .098). Full collapse (P < .001) and extended arterial traction (P = .001) were significantly less frequent for direct aspiration. For direct aspiration with the aspiration catheter not in direct contact with the clot, there was not a single first-pass recanalization and there was systematic arterial collapse, resulting in a no-flow in the aspiration syringe. CONCLUSIONS: The combined technique appears to be more harmful, and although direct aspiration has a lower rate of first-pass recanalization, it seems appropriate to try direct aspiration as a first-line procedure. However, if the aspiration catheter cannot reach the clot, it is not useful or even risky to try aspiration alone. These results need to be confirmed by clinical studies.


Assuntos
Acidente Vascular Cerebral , Trombose , Humanos , Trombectomia/métodos , Resultado do Tratamento , Artérias , Stents , Estudos Retrospectivos
2.
Diagn Interv Imaging ; 101(9): 507-517, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32094095

RESUMO

Magnetic resonance imaging (MRI) has become the reference imaging for the management of a large number of diseases. The number of MR examinations increases every year, simultaneously with the number of patients receiving a cardiac electronic implantable device (CEID). A CEID was considered an absolute contraindication for MRI for years. The progressive replacement of conventional pacemakers and defibrillators by MR-conditional CEIDs and recent data on the safety of MRI in patients with "MR-nonconditional" CEIDs have progressively increased the demand for MRI in patients with a CEID. However, some risks are associated with MRI in CEID carriers, even with "MR-conditional" devices because these devices are not "MR-safe". A specific programing of the device in "MR-mode" and monitoring patients during MRI remain mandatory for all patients with a CEID. A standardized patient workflow based on an institutional protocol should be established in each institution performing such examinations. This joint position paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the Société française d'imagerie cardiaque et vasculaire diagnostique et interventionnelle (SFICV) describes the effect and risks associated with MRI in CEID carriers. We propose recommendations for patient workflow and monitoring and CEID programming in MR-conditional, "MR-conditional nonguaranteed" and MR-nonconditional devices.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Eletrônica , Humanos , Imageamento por Ressonância Magnética
3.
Diagn Interv Imaging ; 101(6): 335-345, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32029386

RESUMO

This article was designed to provide a pediatric cardiac computed tomography angiography (CCTA) expert panel consensus based on opinions of experts of the Société Française d'Imagerie Cardiaque et Vasculaire diagnostique et interventionnelle (SFICV) and of the Filiale de Cardiologie Pédiatrique Congénitale (FCPC). This expert panel consensus includes recommendations for indications, patient preparation, CTA radiation dose reduction techniques, and post-processing techniques. The consensus was based on data from available literature (original papers, reviews and guidelines) and on opinions of a group of specialists with extensive experience in the use of CT imaging in congenital heart disease. In order to reach high potential and avoid pitfalls, CCTA in children with congenital heart disease requires training and experience. Moreover, pediatric cardiac CCTA protocols should be standardized to acquire optimal images in this population with the lowest radiation dose possible to prevent unnecessary radiation exposure. We also provided a suggested structured report and a list of acquisition protocols and technical parameters in relation to specific vendors.


Assuntos
Cardiopatias Congênitas , Exposição à Radiação , Criança , Angiografia por Tomografia Computadorizada , Consenso , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X
4.
Diagn Interv Imaging ; 101(2): 59-67, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31519470

RESUMO

PURPOSE: To evaluate the potential of non-contrast myocardial T1 mapping on cardiovascular magnetic resonance examination (CMR) in differentiating patients with Fabry disease (FD) from those with hypertrophic cardiomyopathy (HCM) and healthy control subjects. MATERIALS AND METHODS: Seventeen patients with FD (8 men, 9 women; mean age, 48 ±18 [SD] years; [range: 19-73 years]; 53% with left ventricular hypertrophy [LVH]) were matched with 36 patients with hypertrophic cardiomyopathy (HCM) (22 men, 14 women; mean age, 57±16 [SD] years; [range: 22-85 years]) and 70 healthy control subjects (34 men, 36 women; mean age, 38 ±15 [SD] years; [range: 18-65 years]). Cardiac T1 mapping was performed using the modified Look-Locker inversion (MOLLI®) sequence on a 1.5-T magnet. T1 values were calculated, on midventricular section, for septal left ventricular segments (S8-S9) and all mid-ventricular ones (global T1 values; S7-S12). Statistical analysis included unpaired Mann-Whitney test, receiver operating characteristic curve and likelihood ratios. RESULTS: Septal native T1 values were significantly decreased in patients with FD (889±61 [SD] ms; range: 784-980ms) compared to those with HCM (995±48 [SD] ms; range: 935-1125ms) (P<0.001) and versus healthy controls (965±29 [SD] ms; range: 910-1028ms) (P<0.001). Global native T1 values were also significantly decreased in patients with FD (891±49 [SD] ms; range 794-970ms) compared to those with HCM (995±34 [SD] ms; range: 952-1086ms) (P<0.001) and versus healthy controls (966±27 [SD] ms; range: 920-1042ms) (P<0.001). A septal left ventricular native T1 cutoff value of 940ms could distinguish FD from HCM with 88% sensitivity (95% CI: 73-100%) and 92% specificity (95% CI: 83-100%). Positive likelihood ratio was 11, negative likelihood ratio was 0.12. Compared to controls, the same threshold could distinguish FD with 88% sensitivity (95% CI: 73-100%) and 86% specificity (95% CI: 78-94%). Positive likelihood ratio was 6.3, negative likelihood ratio was 0.14. T1 value was abnormal in 4 of 8 (50%) of FD patients who did not have LVH. CONCLUSION: Native T1 values are significantly lower in patients with FD by comparison with those with HCM and healthy volunteers.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Mapeamento Epicárdico , Doença de Fabry/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
6.
Diagn Interv Imaging ; 99(11): 689-698, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30262171

RESUMO

PURPOSE: The purpose of this study was to quantify the distribution of trabeculated (T) and compact (C) left ventricular (LV) myocardium masses in a healthy Caucasian population against age, gender and LV parameters, and to provide normal values for T, C and T/C. MATERIALS AND METHODS: One hundred and forty healthy subjects were prospectively recruited and underwent cardiac MRI at 1.5T with a stack of short-axis cine sequences covering the entire LV. End-diastolic volume (EDV), C and T masses were quantified using a semi-automatic method. Ejection fraction (EF) and T/C ratio were computed. RESULTS: We included 70 men and 70 women with a mean age of 44±14 (SD) years (range: 20-69 years). The mean EF was 63.7±6.3 (SD) % (range: 50.7-82.0%), the mean EDV was 75.9±16.2 (SD) mL/m2 (range: 36.4-112.2mL/m2), the mean C mass was 53.9±11.2 (SD) g/m2 (range: 26.5-93.4g/m2) and the mean T mass was 4.9±2.4 (SD) g/m2 (range: 1.1-11.4g/m2). The T/C ratio was 9.2±4.5% (range: 2.0-29.4%). Multivariate ANOVA test showed that the compact mass was influenced by EDV (P<0.0001), EF (P=0.001) and gender (P<0.0001), and the trabeculated mass depended on EDV (P<0.0001), gender (P=0.002) and age (P<0.0001), while the T/C ratio was only influenced by age (P=0.0003). Spearman test showed a correlation between EDV and C (r=0.60; P<0.0001),T (r=0.46; P<0.0001) and T/C ratio (r=0.26; P=0.0023).T and T/C ratio correlated with EF (r=-0.18, P=0.0373; r=-0.18, P=0.0321, respectively). CONCLUSION: While the compact and trabeculated myocardium masses appear to relate separately to the cardiac function, age and gender, their ratio T/C appears to only decrease with age. Furthermore, we propose here normal values for T, C and T/C in a cohort of healthy Caucasians subjects.


Assuntos
Técnicas de Imagem Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Fatores Etários , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais , População Branca , Adulto Jovem
9.
Diagn Interv Imaging ; 99(5): 279-289, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29307461

RESUMO

PURPOSE: To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. METHODS: MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. RESULTS: Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. CONCLUSION: Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve.


Assuntos
Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos
15.
Eur Radiol ; 27(1): 80-87, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27085695

RESUMO

OBJECTIVES: Assessment of perianal fistulas is important to guide management of Crohn's disease (CD). Our objectives were to analyze the feasibility of magnetization transfer (MT) imaging to assess fistulas and to evaluate its contribution in assessing disease activity. METHODS: During 15 months, all patients referred for perianal fistulas in CD underwent 3T-MRI including diffusion, T2/T1-weighted gadolinium-enhanced sequences and MT sequences (one with an off-resonance saturation pulse of 800 and one with 1200 Hz). We collected Van Assche score, fistula activity signs by analyzing T2, diffusion and contrast enhancement. We calculated MT ratio (MTR) with a ROI in the largest fistula. RESULTS: Twenty-nine patients (mean 34.9 years, range 17-53) were included. Van Assche score was 11.7, range 4-21. In 22 patients, the fistula presented with a bright T2 and diffusion signal with contrast enhancement, and was characterized as active. Mean MTR was respectively 47.2 (range 12-68) and 34.3 (range 11-57) at 800 and 1200 Hz. MTR at 800 Hz was significantly lower in non-active (34, range 12-55) than in active fistulas (51, range 24-68) (p < 0.02). CONCLUSIONS: MTR is feasible for the assessment of fistulas in CD and in the future could be used to help identify active and non-active fistulas. KEY POINTS: • MTR is feasible for the assessment of perianal fistulas in CD. • MT allows quantitative imaging of perianal fistula activity in CD. • MTR could be used to help identify active and non-active fistulas in CD.


Assuntos
Doença de Crohn/complicações , Imageamento por Ressonância Magnética/métodos , Fístula Retal/diagnóstico , Adolescente , Adulto , Doença de Crohn/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fístula Retal/etiologia , Reprodutibilidade dos Testes , Adulto Jovem
20.
Diagn Interv Imaging ; 97(5): 505-12, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27012158

RESUMO

The management of patients with congenital heart disease was profoundly changed firstly by the advent of pediatric and prenatal ultrasound and then more recently by cardiac magnetic resonance imaging (MRI) and computed tomography (CT) of the heart and great vessels. The improved life expectancy of these patients has brought about new medical and imaging requirements. MRI and CT are increasing second line techniques in this group of patients. This article summarizes the advantages and limitations of CT and MRI in some frequently encountered situations in children and adults followed up for congenital heart disease.


Assuntos
Técnicas de Imagem Cardíaca/tendências , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento por Ressonância Magnética/tendências , Tomografia Computadorizada por Raios X/tendências , Adulto , Criança , Previsões , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/tendências , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...