Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Life Sci Space Res (Amst) ; 9: 84-92, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27345205

RESUMO

The R3DR2 instrument performed measurements in the European Space Agency (ESA) EXPOSE-R2 platform outside the Russian "Zvezda" module of the International Space Station (ISS) in the period 24 October 2014-11 January 2016. It is the Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2015a). Took place in November 2014, this was the first attempt to monitor a small solar energetic particle (SEP) event outside ISS using the Liulin-type DES (Dachev et al., 2015d). In this study, we describe the dosimetric characteristics of the largest SEP event, observed on 22 June 2015 with the R3DR2 instrument outside ISS. The main finding of this study is that SEP protons with a minimum energy of approximately 7MeV at the surface of the R3DR2 detector produced high dose rates, reaching >5000µGyh(-1), while the inner radiation belt maximum dose was at the level of 2200µGyh(-1). If a virtual external vehicle activity (EVA) was performed in the same period of the SEP maximum on 22 June 2015, the doses obtained in the skin of cosmonauts/astronauts can reach 2.84mGy after 6.5h, which is similar to the average absorbed dose inside ISS for 15days (Reitz et al., 2005). A comparison with other extreme events measured with Liulin-type instruments shows that SEPs similar to that observed on 22 June 2015 could be one of the most dangerous events for the cosmonauts/astronauts involved in EVA.


Assuntos
Radiação Cósmica , Monitoramento de Radiação/instrumentação , Atividade Solar , Voo Espacial/instrumentação , Doses de Radiação , Proteção Radiológica , Fatores de Tempo
3.
Life Sci Space Res (Amst) ; 4: 92-114, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26177624

RESUMO

Ionizing radiation is recognized to be one of the main health concerns for humans in the space radiation environment. Estimation of space radiation effects on health requires the accurate knowledge of the accumulated absorbed dose, which depends on the global space radiation distribution, solar cycle and local shielding generated by the 3D mass distribution of the space vehicle. This paper presents an overview of the spectrometer-dosimeters of the Liulin type, which were developed in the late 1980s and have been in use since then. Two major measurement systems have been developed by our team. The first one is based on one silicon detector and is known as a Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2002, 2003), while the second one is a dosimetric telescope (DT) with two or three silicon detectors. The Liulin-type instruments were calibrated using a number of radioactive sources and particle accelerators. The main results of the calibrations are presented in the paper. In the last section of the paper some of the most significant scientific results obtained in space and on aircraft, balloon and rocket flights since 1989 are presented.


Assuntos
Radiação Cósmica , Doses de Radiação , Monitoramento de Radiação/instrumentação , Radiometria/instrumentação , Meio Ambiente Extraterreno , Humanos , Monitoramento de Radiação/métodos , Radiação Ionizante , Radiometria/métodos , Atividade Solar , Voo Espacial , Astronave
4.
Radiat Prot Dosimetry ; 144(1-4): 611-4, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21186209

RESUMO

Silicon energy deposition spectrometer Liulin was primarily developed for cosmic radiation monitoring onboard spacecrafts. Nowadays, Liulin type detectors are also used to characterise radiation field on board aircraft, at alpine observatories and behind the shielding of heavy ion accelerators. In this work, experiments and calibrations performed in these radiation fields are presented and the method developed for calculation of ambient dose equivalent H*(10) on board aircraft is described. Since 2001, a simple method employing the energy deposition spectra had been used to determine H*(10) on board aircraft but, in 2004, it became clear that the resulting values were strongly biased at locations close to Earth's equator. An improved method for the determination of H*(10) on board aircraft using the Liulin detector was developed. It took into account the composition of the radiation field via the ratio of absorbed doses D(low) and D(neut) reflecting the contributions from low-LET particles and neutrons, respectively. It resulted in much better agreement with the EPCARD computer code for all aircraft locations; relative differences were within 11 % for low-LET and 20 % for neutron components of H*(10).


Assuntos
Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Análise Espectral/instrumentação , Aeronaves , Algoritmos , Calibragem , Radiação Cósmica , República Tcheca , Humanos , Modelos Estatísticos , Nêutrons , Aceleradores de Partículas , Doses de Radiação , Silício/química , Dióxido de Silício/química , Astronave , Análise Espectral/métodos
5.
Radiat Prot Dosimetry ; 126(1-4): 519-23, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17496293

RESUMO

The neutron contribution to the spacecraft crew exposure could represent an important part of the total dose equivalent value. The determination of this contribution represents a rather complex and difficult task, both through experimental and theoretical estimation. This paper will present an attempt to determine the neutron contribution onboard the International Space Station and Foton capsule using the data measured by means of a Si-diode based energy deposition spectrometer. As such a spectrometer, the MDU-Liulin equipment, developed in one of our laboratories was used. The equipment allows the data accumulated during the passage in or out of the South Atlantic Anomaly (SAA). In this paper, only the data obtained out of the SAA were analysed, assuming that the neutron spectra are similar to those onboard aircraft and/or at the CERF high-energy radiation field. The excess of deposited energy in the region above 1 MeV, when comparing with the aircraft field, was expected to represent the primary high-energy charged particles. Total dosimetry characteristics obtained in this way are in reasonable agreement with other data, neutron contribution representing approximately 40% of the total dose equivalent for the flight duration outside of the SAA.


Assuntos
Radiação Cósmica , Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Voo Espacial , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Radiat Prot Dosimetry ; 100(1-4): 525-8, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12382935

RESUMO

Radiation fields on board aircraft contain particles with energies up to a few hundred MeV. Many instruments have been tested to characterise these fields. This paper presents the results of studies on the use of an Si diode spectrometer to characterise these fields. The spectrometer has been in use since spring 2000 on more than 130 return flights to monitor and characterise the on-board field. During a Czech Airlines flight from Prague to New York it was possible to register the effects of an intense solar flare, (ground level event, GLE 60), which occurred on 15 April 2001. It was found that the number of deposition events registered was increased by about 70% and the dose in Si by a factor of 2.0 when compared with the presence of galactic cosmic rays alone. Directly measured data are interpreted with respect to on-earth reference field calibration (photons, CERN high-energy particles): it was found that this approach leads to encouraging results and should be followed up.


Assuntos
Aeronaves , Radiação Cósmica/efeitos adversos , Monitoramento de Radiação/instrumentação , Análise Espectral/instrumentação , Medicina Aeroespacial/instrumentação , Humanos , Semicondutores , Silício
8.
Acta Astronaut ; 42(1-8): 375-87, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-11541621

RESUMO

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.


Assuntos
Aceleradores de Partículas , Monitoramento de Radiação/instrumentação , Voo Espacial/instrumentação , Astronave/instrumentação , Partículas alfa , Calibragem , Radiação Cósmica , Desenho de Equipamento , Íons Pesados , Transferência Linear de Energia , Doses de Radiação , Radiometria , Atividade Solar
9.
Adv Space Res ; 14(10): 707-10, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11540012

RESUMO

The dosimetric experiments Dose-M and Liulin as part of the more complex French-German-Bulgarian-Russian experiments for the investigation of the radiation environment for Mars-96 mission are described. The experiments will be realized with dosemeter-radiometer instruments, measuring absorbed dose in semiconductor detectors and the particle flux. Two detectors will be mounted on board the Mars-96 orbiter. Another detector will be on the guiderope of the Mars-96 Aerostate station. The scientific aims of Dose-M and Liulin experiments are: Analysis of the absorbed dose and the flux on the path and around Mars behind different shielding. Study of the shielding characteristics of the Martian atmosphere from galactic and solar cosmic rays including solar proton events. Together with the French gamma-spectrometer and the German neutron detectors the investigation of the radiation environment on the surface of Mars and in the atmosphere up to 4000 m altitude will be conducted.


Assuntos
Radiação Cósmica , Monitoramento de Radiação/instrumentação , Atividade Solar , Voo Espacial/instrumentação , Astronave/instrumentação , Marte , Doses de Radiação , Proteção Radiológica , Radiometria , Projetos de Pesquisa , Astronave/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...