Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Brachytherapy ; 17(4): 718-725, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29776892

RESUMO

PURPOSE: Cholangiocarcinoma patients who are potential candidates for liver transplantation may be treated with high-dose-rate (HDR) brachytherapy using a minimally invasive nasobiliary catheter in an effort to escalate the radiotherapy dose to the tumor and maximize local control rates. This work describes the equipment, procedures, and quality assurance (QA) that enables successful administration. METHODS AND MATERIALS: This work describes the nasobiliary catheter placement, simulation, treatment planning, treatment delivery, and QA. In addition, a chart review was performed of all patients who received endoscopic retrograde cholangiopancreatography for HDR bile duct brachytherapy at our institution from 2007 to 2017. The review evaluated how many patients were treated and the number of patients who could not be treated because of anatomic and/or equipment limitations. RESULTS: From 2007 to 2017, 122 cholangiocarcinoma patients have been treated with HDR brachytherapy using a nasobiliary catheter. Three patients underwent catheter placement but did not receive brachytherapy treatment due to catheter migration between placement and treatment or because the HDR afterloader was unable to extend the source wire into the treatment site. Periodic QA is recommended for ensuring whether the HDR afterloader is capable of extending the source wire through an extensive and curved path. CONCLUSIONS: Intraluminal HDR brachytherapy with a nasobiliary catheter can be successfully administered. Procedures and QA are described for ensuring safety and overcoming technical challenges.


Assuntos
Neoplasias dos Ductos Biliares/radioterapia , Braquiterapia/métodos , Cateterismo/métodos , Catéteres , Colangiocarcinoma/radioterapia , Adulto , Ductos Biliares , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nariz , Dosagem Radioterapêutica
2.
Brachytherapy ; 15(4): 531-536, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27184646

RESUMO

PURPOSE: The ability to create treatment plans for intraoperative high-dose-rate (IOHDR) brachytherapy is limited by lack of imaging and time constraints. An automated method for creation of a library of high-dose-rate brachytherapy plans that can be used with standard planar applicators in the intraoperative setting is highly desirable. METHODS AND MATERIALS: Nonnegative least squares algebraic methods were used to identify dwell time values for flat, rectangular planar applicators. The planar applicators ranged in length and width from 2 cm to 25 cm. Plans were optimized to deliver an absorbed dose of 10 Gy to three different depths from the patient surface: 0 cm, 0.5 cm, and 1.0 cm. Software was written to calculate the optimized dwell times and insert dwell times and positions into a .XML plan template that can be imported into the Varian brachytherapy treatment planning system. The user may import the .XML template into the treatment planning system in the intraoperative setting to match the patient applicator size and prescribed treatment depth. RESULTS: A total of 1587 library plans were created for IOHDR brachytherapy. Median plan generation time was approximately 1 minute per plan. Plan dose was typically 100% ± 1% (mean, standard deviation) of the prescribed dose over the entire length and width of the applicator. Plan uniformity was best for prescription depths of 0 cm and 0.5 cm from the patient surface. CONCLUSIONS: An IOHDR plan library may be created using automated methods. Thousands of plan templates may be optimized and prepared in a few hours to accommodate different applicator sizes and treatment depths and reduce treatment planning time. The automated method also enforces dwell time symmetry for symmetrical applicator geometries, which simplifies quality assurance.


Assuntos
Automação , Braquiterapia/métodos , Protocolos Clínicos , Neoplasias/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Cuidados Intraoperatórios/métodos , Análise dos Mínimos Quadrados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...