Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
2.
Open Biomed Eng J ; 12: 51-71, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30258499

RESUMO

BACKGROUND: In scoliosis, kypholordos and wedge properties of the vertebrae should be involved in determining how stress is distributed in the vertebral column. The impact is logically expected to be maximal at the apex. AIM: To introduce an algorithm for constructing artificial geometric models of the vertebral column from DICOM stacks, with the ultimate aim to obtain a formalized way to create simplistic models, which enhance and focus on wedge properties and relative tilting. MATERIAL/METHODS: Our procedure requires parameter extraction from DICOM image-stacks (with PACS,IDS-7), mechanical FEM-modelling (with Matlab and Comsol). As a test implementation, models were constructed for five patients with thoracal idiopathic scoliosis with varying apex rotation. For a selection of load states, we calculated a response variable which is based upon distortion energy. RESULTS: For the test implementation, pairwise t-tests show that our response variable is non-trivial and that it is chiefly sensitive to the transversal stresses (transversal stresses where of main interest to us, as opposed to the case of additional shear stresses, due to the lack of explicit surrounding tissue and ligaments in our model). Also, a pairwise t-test did not show a difference (n = 25, p-value≈0.084) between the cases of isotropic and orthotropic material modeling. CONCLUSION: A step-by-step description is given for a procedure of constructing artificial geometric models from chest CT DICOM-stacks, such that the models are appropriate for semi-global stress-analysis, where the focus is on the wedge properties and relative tilting. The method is inappropriate for analyses where the local roughness and irregularities of surfaces are wanted features. A test application hints that one particular load state possibly has a high correlation to a certain response variable (based upon distortion energy distribution on a surface of the apex), however, the number of patients is too small to draw any statistical conclusions.

3.
Eur Radiol ; 22(3): 642-53, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21984449

RESUMO

OBJECTIVES: To develop and evaluate a procedure for quantifying the hepatocyte-specific uptake of Gd-BOPTA and Gd-EOB-DTPA using dynamic contrast-enhanced (DCE) MRI. METHODS: Ten healthy volunteers were prospectively recruited and 21 patients with suspected hepatobiliary disease were retrospectively evaluated. All subjects were examined with DCE-MRI using 0.025 mmol/kg of Gd-EOB-DTPA. The healthy volunteers underwent an additional examination using 0.05 mmol/kg of Gd-BOPTA. The signal intensities (SI) of liver and spleen parenchyma were obtained from unenhanced and enhanced acquisitions. Using pharmacokinetic models of the liver and spleen, and an SI rescaling procedure, a hepatic uptake rate, K (Hep), estimate was derived. The K (Hep) values for Gd-EOB-DTPA were then studied in relation to those for Gd-BOPTA and to a clinical classification of the patient's hepatobiliary dysfunction. RESULTS: K (Hep) estimated using Gd-EOB-DTPA showed a significant Pearson correlation with K (Hep) estimated using Gd-BOPTA (r = 0.64; P < 0.05) in healthy subjects. Patients with impaired hepatobiliary function had significantly lower K (Hep) than patients with normal hepatobiliary function (K (Hep) = 0.09 ± 0.05 min(-1) versus K (Hep) = 0.24 ± 0.10 min(-1); P < 0.01). CONCLUSIONS: A new procedure for quantifying the hepatocyte-specific uptake of T (1)-enhancing contrast agent was demonstrated and used to show that impaired hepatobiliary function severely influences the hepatic uptake of Gd-EOB-DTPA. KEY POINTS: • The liver uptake of contrast agents may be measured with standard clinical MRI. • Calculation of liver contrast agent uptake is improved by considering splenic uptake. • Liver function affects the uptake of the liver-specific contrast agent Gd-EOB-DTPA. • Hepatic uptake of two contrast agents (Gd-EOB-DTPA, Gd-BOPTA) is correlated in healthy individuals. • This method can be useful for determining liver function, e.g. before hepatic surgery.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Hepatopatias/diagnóstico , Hepatopatias/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Meglumina/farmacocinética , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Baço/metabolismo , Resultado do Tratamento
4.
Acta Radiol ; 50(7): 709-15, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19701821

RESUMO

BACKGROUND: A thorough understanding of magnetic resonance (MR) contrast media dynamics makes it possible to choose the optimal contrast media for each investigation. Differences in visualizing hepatobiliary function between Gd-BOPTA and Gd-EOB-DTPA have previously been demonstrated, but less has been published regarding differences in liver vessel visualization. PURPOSE: To compare the liver vessel and liver parenchymal enhancement dynamics of Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist). MATERIAL AND METHODS: The signal intensity of the liver parenchyma, the common hepatic artery, the middle hepatic vein, and a segmental branch of the right portal vein was obtained in 10 healthy volunteers before contrast media administration, during arterial and portal venous phases, and 10, 20, 30, 40, and 130 min after intravenous contrast medium injection, but, due to scanner limitations, not during the hepatic venous phase. The doses of contrast media were 0.1 mmol/kg for Gd-BOPTA and 0.025 mmol/kg for Gd-EOB-DTPA. RESULTS: Maximum enhancement of liver parenchyma was observed from the portal venous phase until 130 min after Gd-BOPTA administration and from 10 min to 40 min after Gd-EOB-DTPA. There was no difference in maximum enhancement of liver parenchyma between the two contrast media. When using Gd-BOPTA, the vascular contrast enhancement was still apparent 40 min after injection, but had vanished 10 min after Gd-EOB-DTPA injection. The maximum difference in signal intensity between the vessels and the liver parenchyma was significantly greater with Gd-BOPTA than with Gd-EOB-DTPA (P<0.0001). CONCLUSION: At the dosage used in this study, Gd-BOPTA yields higher maximum enhancement of the hepatic artery, portal vein, and middle hepatic vein during the arterial and the portal venous phase and during the delayed phases than Gd-EOB-DTPA does, whereas there is no difference in liver parenchymal enhancement between the two contrast agents.


Assuntos
Gadolínio DTPA , Circulação Hepática , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Funções Verossimilhança , Masculino , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem
5.
Acta Radiol ; 48(4): 362-8, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17453513

RESUMO

PURPOSE: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection. RESULTS: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA. CONCLUSION: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.


Assuntos
Ductos Biliares/anatomia & histologia , Meios de Contraste , Gadolínio DTPA , Gadolínio , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Ductos Biliares Intra-Hepáticos/anatomia & histologia , Meios de Contraste/administração & dosagem , Feminino , Gadolínio/administração & dosagem , Gadolínio DTPA/administração & dosagem , Ducto Hepático Comum/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Injeções Intravenosas , Fígado/anatomia & histologia , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Fatores de Tempo
6.
Acta Radiol ; 47(2): 172-8, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16604964

RESUMO

PURPOSE: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. MATERIAL AND METHODS: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. RESULTS: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). CONCLUSION: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Angiografia por Ressonância Magnética/normas , Análise de Variância , Angiografia Digital , Meios de Contraste , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Variações Dependentes do Observador , Estudos Retrospectivos
7.
BMC Med Imaging ; 6: 1, 2006 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-16630362

RESUMO

BACKGROUND: Computed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated. METHODS: The medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed. RESULTS: Contrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 micromol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25-133 micromol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction - a pricking sensation in the face. No other adverse effects were noted. CONCLUSION: We conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion. In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated.

8.
Br J Radiol ; 78(936): 1078-85, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16352582

RESUMO

The purpose of this study was to evaluate the diagnostic potential of prolonged drip infusion CT cholangiography (DIC-CT) using meglumine iotroxate (Biliscopin) and 3D volume rendering in patients with suspected obstructive biliary disease. From a material of 142 patients who had undergone a drip infusion CT, all cases with a verified surgical or endoscopic retrograde cholangiography (ERC) diagnosis (n=33) were selected. Age-matched controls were selected from the remaining examinations. Three radiologists reviewed all 66 examinations in retrospect, independently as well as in consensus. The image quality and the estimated diagnostic quality were rated as good or moderate in 91% of the 198 reviews. The consensus sensitivity and specificity for diagnosing biliary stones was 88% and 94%, respectively (with sensitivities ranging from 88% to 94% for individual observers, and specificities from 86% to 96%). Two out of three strictures were observed. No false positive strictures were described. The use of volume rendering technique (VRT) improved diagnostic certainty in 28/198 (14%) of the evaluations. The visualization of ductal stones was improved in 18/48 (38%). No differences in diagnostic quality between single and multislice CT were observed. We conclude that a detailed image of the biliary tree with good sensitivity and specificity can be obtained by means of bilirubin-governed infusion time DIC-CT with volume rendering reconstruction.


Assuntos
Cálculos Biliares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Bilirrubina/sangue , Colangiografia/métodos , Colangiopancreatografia Retrógrada Endoscópica , Meios de Contraste , Feminino , Cálculos Biliares/patologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Infusões Intravenosas , Iodopamida/administração & dosagem , Iodopamida/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
9.
Acta Radiol ; 45(4): 453-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15323400

RESUMO

PURPOSE: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets. MATERIAL AND METHODS: Existing contrast-enhanced 3-dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed. RESULTS: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly. CONCLUSIONS: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user-selected settings.


Assuntos
Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/patologia , Angiografia por Ressonância Magnética , Idoso , Análise de Variância , Angiografia Digital/estatística & dados numéricos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia
10.
Acta Radiol ; 44(2): 177-84, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12694105

RESUMO

PURPOSE: 1) To compare measurements obtained with MR imaging (MRI)/contrast-enhanced MR angiography (CE MRA) with measurements obtained with angiography (DSA) and CT, for stent-graft sizing of abdominal aortic aneurysms (AAA). 2) To compare MRA measurements obtained with the two post processing techniques MIP (maximum intensity projection) and VRT (3D volume rendering technique). MATERIAL AND METHODS: The prospective study included 20 consecutive patients with AAA identified by DSA and CT as suitable for endovascular repair. For the study, MRI/CE MRA was performed. Five measurement variables for stent-graft sizing were chosen. Comparisons were made between MRI/CE MRA, DSA and CT, and between observers. Comparisons were also made between MIP and VRT. RESULTS: Significantly shorter lengths were obtained with MRA-MIP than with DSA. Three out of six diameter measurements were significantly smaller on MRI/CE MRA than on DSA and CT. No significant differences were found between the observers. One diameter measurement was significantly smaller on MIP than on VRT, while the other measurements showed no significant differences. CONCLUSION: The length measurements obtained with MRA-MIP were probably more correct than those with DSA. For more reliable diameter measurements with CE MRA, improvements of the technique, including VRT reconstructions and a standardized determination of the vessel boundaries, are needed.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...