Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Insights Imaging ; 15(1): 11, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38228903

RESUMO

OBJECTIVES: To evaluate the image quality and utility of virtual monoenergetic images (VMI) of dual-layer spectrum computed tomography (DLSCT) in assessing preoperative T-stage for early rectal adenocarcinoma (ERA). METHODS: This retrospective study included 67 ERA patients (mean age 62 ± 11.1 years) who underwent DLSCT and MR examination. VMI 40-200 keV and poly energetic image (PEI) were reconstructed. The image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and tumor contrast of different energy levels were calculated and compared, respectively. Two radiologists independently assess the image quality of the VMIs and PEI using 5-point scales. The diagnostic accuracies of DLSCT and HR-MRI for ERA T-staging were evaluated and compared. RESULTS: The maximum noise was observed at VMI 40 keV, and noise at VMI 40-200 keV in the arterial and venous phases showed no significant difference (all p > 0.05). The highest SNR and CNR were obtained at VMI 40 keV, significantly greater than other energy levels and PEI (all p < 0.05). Tumor contrast was more evident than PEI at 40-100 keV in the arterial phase and at 40 keV in the venous phase (all p < 0.05). When compared with PEI, VMI 40 keV yielded the highest scores for overall image quality, tumor visibility, and tumor margin delineation, especially in the venous phase (p < 0.05). The overall diagnostic accuracy of DLSCT and HR-MRI for T-stage was 65.67 and 71.64% and showed no significant difference (p > 0.05). CONCLUSIONS: VMI 40 keV improves image quality and accuracy in identifying lesions, providing better diagnostic information for ERA staging. CRITICAL RELEVANCE STATEMENT: Low-keV VMI from DLSCT can improve tumor staging accuracy for early rectal carcinoma, helping guide surgical intervention decisions, and has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC. KEYPOINTS: • Compared with PEI, low-keV VIM derived from DLSCT, particularly at the 40 keV, significantly enhanced the objective and subjective image quality of ERA. • Using VMI 40 keV helped increase lesion detectability, leading to improved diagnostic accuracy for ERA. • Low-keV VMI from DLSCT has shed new light on the potential breakthroughs of assessing preoperative T-stage in RC.

2.
Phys Rev Lett ; 129(27): 273603, 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36638288

RESUMO

Floquet modulation has been widely used in optical lattices for coherent control of quantum gases, in particular for synthesizing artificial gauge fields and simulating topological matters. However, such modulation induces heating which can overwhelm the signal of quantum dynamics in ultracold atoms. Here we report that the thermal motion, instead of being a noise source, provides a new control knob in Floquet-modulated superradiance lattices, which are momentum-space tight-binding lattices of collectively excited states of atoms. The Doppler shifts combined with Floquet modulation provide effective forces along arbitrary directions in a lattice in frequency and momentum dimensions. Dynamic localization, dynamic delocalization, and chiral edge currents can be simultaneously observed from a single transport spectrum of superradiance lattices in thermal atoms. Our Letter paves a way for simulating Floquet topological matters in room-temperature atoms and facilitates their applications in photonic devices.

3.
Medicine (Baltimore) ; 100(12): e25202, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33761705

RESUMO

ABSTRACT: To introduce a novel technique of using individualized 3D printing occipitocervical fusion instrument (3D-OCF) for the treatment of upper cervical deformity with atlantoaxial joint dislocation.The surgery for deformity of the craniocervical junction area is a challenge in the field of spine. If the surgical deviation is too large to injure the spinal cord or vertebral artery, it will cause catastrophic damage to the patient. Therefore, it is controversial whether these patients should undergo surgical treatment. We provide a novel surgical approach for the challenging upper cervical surgery through 3D-OCF and a typical patient.We present a 54-year-old female patient, who suffered from dizziness and numbness in her limbs for 8 months. After the patient was admitted, we performed the three-dimensional CT scan, modeled using Mimics software 17.0, and designed customized occipitocervical fusion instrument. Besides, we repeatedly perform simulated surgery based on 3D-printed models before surgery.The operative time was 142 minutes and the intraoperative blood loss was 700 mL. X-ray showed reduction of atlantoaxial dislocation and accurate position of internal fixation. The patient's symptoms were significantly relieved: the sensation of dizziness and numbness of limbs was obviously relieved, and the sense of banding in chest, abdomen, and ankle was disappeared. At the last follow-up, imaging showed that 3D-OCF had bone-integration and Syringomyelia was disappeared. The patient's cervical JOA (Japanese Orthopaedic Association) score increased from 10 points to 17 points.Individualized 3D-OCF can improve the safety and accuracy of upper cervical surgery, reduce the operative time and the number of fluoroscopy. Our study provides a novel surgical approach for the challenging upper cervical surgery.


Assuntos
Articulação Atlantoaxial/anormalidades , Articulação Atlantoaxial/cirurgia , Vértebras Cervicais/cirurgia , Luxações Articulares/cirurgia , Osso Occipital/cirurgia , Impressão Tridimensional , Fusão Vertebral/instrumentação , Articulação Atlantoaxial/diagnóstico por imagem , Articulação Atlantoaxial/patologia , Perda Sanguínea Cirúrgica , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/patologia , Pessoa de Meia-Idade , Osso Occipital/diagnóstico por imagem , Duração da Cirurgia , Ossificação Heterotópica/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X
4.
PLoS One ; 12(2): e0171509, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28152039

RESUMO

PURPOSE: Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. METHODS: Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. RESULTS: A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. CONCLUSION: The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.


Assuntos
Vértebras Cervicais/cirurgia , Fixação Interna de Fraturas/instrumentação , Parafusos Pediculares , Impressão Tridimensional , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Feminino , Fluoroscopia , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...