1.
Work ; 70(4): 1219-1227, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34842207

RESUMO

BACKGROUND: Standards writers, national and international, have used different contrast calculations to set requirements in building elements for people with visual impairments. On the other hand, they have typically set a single requirement (30%) for specifying the minimum contrast. The systems are not linearly related and 30% means something rather different in each system. OBJECTIVE: To provide a comparison of the various scales in order to illustrate the differences caused by multiple scales with a single compliance value, recommend a single scale for universal adoption and, if a new measure is problematic for implementation, to recommend the most perceptually uniform of the present methods. METHODS: We use the contrast between combinations of 205 paint colours to illustrate the relationships between the measures. We use an internationally accepted scale, with equal perceptual steps, as a "gold standard" to identify the most perceptually uniform measurement scale in the existing methods. RESULTS: We show that Michelson contrast is the most perceptually uniform of the existing measurement scales. We show the contrasts in the proposed method that equate to the various current requirements. CONCLUSIONS: We propose that CIE Metric Lightness could be used as the contrast measure. Alternatively, Michelson contrast is the most perceptually linear of the current measurement scales.


Assuntos
Pessoas com Deficiência , Humanos , Projetos de Pesquisa
2.
Ophthalmic Physiol Opt ; 30(3): 253-6, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20444131

RESUMO

PURPOSE: The Optics and Radiometry Laboratory (ORLAB) provides a testing service for the Australian sunglass industry to assist its compliance with the mandatory Consumer Product Safety Standard. In doing so, a number of sunglasses carrying the CE mark (in effect a claim of compliance with the European Union Personal Protective Equipment Directive) have been tested. Since there is no mandatory testing in Europe (the sunglass industry is deemed self regulating), evaluating their performance will give an insight into compliance with the Directive. METHODS: Consecutive submissions to ORLAB over a period of 18 months were examined for CE marked sunglasses. The results for 646 CE marked pairs of sunglasses tested during 2003 and first half 2004 were examined and evaluated for compliance with EN 1836 (the European sunglass standard) on the basis of refractive power, prismatic power, transmittance (visible, UV and coloration) and polarization. RESULTS: A total of 17.3% failed EN 1836 and 3.3% were borderline (i.e. within our uncertainties of measurement of the requirement). The failures comprised: 0.9% lens defect; 12.5% polarization alignment error; 2.7% excessive vertical prism; 22.3% excessive horizontal prism; 27.7% excessive spherical power; 14.3% excessive cylindrical power; 1.8% excessive UV transmittance; and 23.2% transmittance difference between lenses (always gradient tints). CONCLUSION: With up to 20% non-compliance, self regulation is not working particularly well in providing the public with complying sunglasses.


Assuntos
Óculos/normas , Fidelidade a Diretrizes , Lentes/normas , Proteção Radiológica/normas , Raios Ultravioleta , Qualidade de Produtos para o Consumidor/legislação & jurisprudência , Europa (Continente) , Filtração , Óptica e Fotônica