Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiol Prot ; 41(4)2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34587595

RESUMO

In 2020, the UK environmental regulators and food safety agencies, published the 25th edition of the Radioactivity in Food and the Environment (RIFE) report. This marks a quarter of a century since the landmark RIFE report was first published by the Ministry of Agriculture, Fisheries and Food in 1996, which represented the first joint monitoring and assessment report for the United Kingdom. This paper provides a summary of the RIFE report, how it has evolved and presents some case studies from over the 25 year period.


Assuntos
Inocuidade dos Alimentos , Reino Unido
2.
J Radiol Prot ; 2017 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-28871075

RESUMO

Radiological exposures due to naturally occurring radioactive material (NORM) can occur during a wide range of work-related activities in the mineral processing and chemical industries. However, evaluation of such exposures in industrial settings remains a difficult exercise owing inter alia to the large number of personnel, operations and plants affected; assumptions that often have to be made concerning the actual duration and frequency of exposures; the complex chemistry and radioactive disequilibria involved and typically, the paucity of historical data. In our study, the challenges associated with assessing chronic exposure to fugitive dust enriched in 210Pb and 210Po and the determination of the associated internal dose by inhalation and ingestion are described by reference to a case study undertaken at an iron ore sintering plant between June 2013 and July 2015. The applicability of default dose coefficients and biokinetic models provided by the International Commission for Radiological Protection (ICRP) was verified by combining air and dust monitoring with information on the characteristics of the aerosols and in-vitro solubility experiments. The disparity between particulate matter 100 microns or less in diameter (PM100), particulate matter 10 microns or less in diameter (PM10) and 210Pb/210Po activity concentrations observed over the different monitoring campaigns and sampling locations confirmed that use of positional short-term monitoring surveys to extrapolate intake over a year was not appropriate and could lead to unrealistic intake and dose figures. Personal air sampling is more appropriate for estimating the dose in such situations, though it is not always practical and may collect insufficient quantities of material for radiochemical analysis; this is an important constraint when dealing with low specific activity materials.

3.
J Radiol Prot ; 37(2): 402-421, 2017 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-28425430

RESUMO

Radiological exposures due to naturally occurring radioactive material (NORM) can occur during a wide range of work-related activities in the mineral processing and chemical industries. However, evaluation of such exposures in industrial settings remains a difficult exercise owing inter alia to the large number of personnel, operations and plants affected; assumptions that often have to be made concerning the actual duration and frequency of exposures; the complex chemistry and radioactive disequilibria involved and typically, the paucity of historical data. In our study, the challenges associated with assessing chronic exposure to fugitive dust enriched in 210Pb and 210Po and the determination of the associated internal dose by inhalation and ingestion are described by reference to a case study undertaken at an iron ore sintering plant between June 2013 and July 2015. The applicability of default dose coefficients and biokinetic models provided by the International Commission for Radiological Protection was verified by combining air and dust monitoring with information on the characteristics of the aerosols and in-vitro solubility experiments. The disparity between particulate matter 100 microns or less in diameter (PM100), particulate matter 10 microns or less in diameter (PM10) and 210Pb/210Po activity concentrations observed over the different monitoring campaigns and sampling locations confirmed that use positional short-term monitoring surveys to extrapolate intake over a year was not appropriate and could lead to unrealistic intake and dose figures. Personal air sampling is more appropriate for estimating the dose in such situations, though it is not always practical and may collect insufficient quantities of material for radiochemical analysis; this is an important constraint when dealing with low specific activity materials.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluentes Radioativos do Ar/análise , Ferro , Exposição Ocupacional/análise , Monitoramento de Radiação/métodos , Aerossóis/análise , Poeira/análise , Ingestão de Alimentos , Humanos , Indústrias , Exposição por Inalação , Material Particulado/análise , Proteção Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...