1.
Nat Methods ; 11(5): 541-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24705473

RESUMO

Light-sheet microscopy facilitates rapid, high-contrast, volumetric imaging with minimal sample exposure. However, the rapid divergence of a traditional Gaussian light sheet restricts the field of view (FOV) that provides innate subcellular resolution. We show that the Airy beam innately yields high contrast and resolution up to a tenfold larger FOV. In contrast to the Bessel beam, which also provides an increased FOV, the Airy beam's characteristic asymmetric excitation pattern results in all fluorescence contributing positively to the contrast, enabling a step change for light-sheet microscopy.


Assuntos
Microscopia/instrumentação , Animais , Linhagem Celular Tumoral , Membrana Celular/metabolismo , Simulação por Computador , Desenho de Equipamento , Corantes Fluorescentes/química , Luz , Microscopia/métodos , Microscopia de Fluorescência/métodos , Microesferas , Distribuição Normal , Óptica e Fotônica , Espalhamento de Radiação , Peixe-Zebra
2.
J R Soc Interface ; 8(60): 942-51, 2011 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-21247948

RESUMO

We describe a method for tracking the position of small features in three dimensions from images recorded on a standard microscope with an inexpensive attachment between the microscope and the camera. The depth-measurement accuracy of this method is tested experimentally on a wide-field, inverted microscope and is shown to give approximately 8 nm depth resolution, over a specimen depth of approximately 6 µm, when using a 12-bit charge-coupled device (CCD) camera and very bright but unresolved particles. To assess low-flux limitations a theoretical model is used to derive an analytical expression for the minimum variance bound. The approximations used in the analytical treatment are tested using numerical simulations. It is concluded that approximately 14 nm depth resolution is achievable with flux levels available when tracking fluorescent sources in three dimensions in live-cell biology and that the method is suitable for three-dimensional photo-activated localization microscopy resolution. Sub-nanometre resolution could be achieved with photon-counting techniques at high flux levels.


Assuntos
Biologia Celular/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Microscopia/instrumentação , Modelos Teóricos , Microscopia/métodos
3.
Opt Express ; 18(2): 877-84, 2010 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-20173908

RESUMO

A conventional microscope produces a sharp image from just a single object-plane. This is often a limitation, notably in cell biology. We present a microscope attachment which records sharp images from several object-planes simultaneously. The key concept is to introduce a distorted diffraction grating into the optical system, establishing an order-dependent focussing power in order to generate several images, each arising from a different object-plane. We exploit this multiplane imaging not just for bio-imaging but also for nano-particle tracking, achieving approximately 10 nm z position resolution by parameterising the images with an image sharpness metric.


Assuntos
Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Microscopia/instrumentação , Nanopartículas/ultraestrutura , Nanotecnologia/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...