Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesthesiology ; 121(6): 1184-93, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25105423

RESUMO

BACKGROUND: Esmolol is marketed as a racemate (RS-esmolol) with hypotension being the most frequently reported adverse event. Previously, it has been shown that the S-enantiomer (S-esmolol) possesses all of the heart rate (HR) control. The authors studied whether S-esmolol alone mitigates hypotension at similar degrees of HR control compared with RS-esmolol. METHODS: The effects of RS- and S-esmolol on blood pressure (BP) were compared at multiple infusion rates producing similar HR control in dogs (N=21). Differences in BP were further interrogated by monitoring global cardiovascular function and included the R-enantiomer (R-esmolol) (N=3). RESULTS: S-esmolol at half the rate (µg kg min) of RS-esmolol provided the same degree of HR control over all infusion rates. RS-esmolol lowered BP by 3, 6, 11, 20, and 38 mmHg at 90, 300, 600, 1,000, and 2,000 µg kg min, compared with 2, 4, 5, 10, and 16 mmHg at 45, 150, 300, 500, and 1,000 µg kg min for S-esmolol. Decreased BP with RS-esmolol was attributed to decreases in left ventricular developed pressure (LVDP) (-34 mmHg), LVdP/dt+max (-702 mmHg/s), and cardiac output (-1 l/min). R-esmolol also decreased BP (-10 mmHg), LVDP (-10 mmHg), LVdP/dt+max (-241 mmHg/s), and cardiac output (to -0.2 l/min). S-esmolol reversed these trends toward pre-esmolol values by increasing BP (+13 mmHg), LVDP (+12 mmHg), LVdP/dt+max (+76 mmHg/s), and cardiac output (+0.4 l/min). CONCLUSIONS: R-enantiomer provided no HR control, but contributed to the hypotension with RS-esmolol, which appears to be due to negative inotropy. Thus, an S-enantiomer formulation of esmolol may provide similar HR control with less hypotension.


Assuntos
Antagonistas Adrenérgicos beta/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Hipotensão/tratamento farmacológico , Propanolaminas/farmacologia , Agonistas Adrenérgicos beta/farmacologia , Antagonistas Adrenérgicos beta/química , Antagonistas Adrenérgicos beta/farmacocinética , Animais , Pressão Arterial/efeitos dos fármacos , Procedimentos Cirúrgicos Cardíacos , Cães , Estabilidade de Medicamentos , Isoproterenol/antagonistas & inibidores , Isoproterenol/farmacologia , Propanolaminas/química , Propanolaminas/farmacocinética , Estereoisomerismo
2.
Blood Purif ; 36(2): 84-91, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23989183

RESUMO

BACKGROUND: Baxter received reports of visible precipitate, identified as calcium carbonate, forming during hemofiltration with Accusol 35 solution. AIM: To evaluate the potential for acute cardiopulmonary adverse effects of Accusol 35 containing exaggerated calcium carbonate particles. METHODS: Anesthetized dogs underwent continuous veno-venous hemofiltration (CVVH) with Accusol 35 containing visible and subvisible particles (≥10 µm) 36 times higher than the maximum concentration specified in the European Pharmacopoeia (P-Accusol), or Accusol 35 conforming to specification (Accusol). Select cardiovascular and blood gas parameters were evaluated during CVVH. Lung tissue samples were collected following CVVH. RESULTS: No differences were observed in cardiovascular and blood gas parameters or lung histology between P-Accusol and Accusol. CONCLUSION: Accusol 35 containing visible and subvisible particles (≥10 µm) 36 times higher than the maximum concentration specified in the European Pharmacopoeia resulted in no acute cardiopulmonary adverse effects compared with Accusol 35 containing no visible particles and subvisible particles within European Pharmacopoeia specification.


Assuntos
Carbonato de Cálcio/química , Traumatismos Cardíacos/etiologia , Soluções para Hemodiálise/efeitos adversos , Soluções para Hemodiálise/química , Hemofiltração/efeitos adversos , Hemofiltração/métodos , Lesão Pulmonar/etiologia , Animais , Cristalização , Cães , Concentração de Íons de Hidrogênio , Lesão Pulmonar/patologia , Masculino , Modelos Animais , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...