Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 266: 120418, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-34600325

RESUMO

We report the development of a compact near-infrared (NIR) laser-based trace methane (CH4) detection system. This detection system relied on a 2334 nm distributed feedback (DFB) fiber laser as the light source. A parallel dense light-spot pattern multipass gas cell (MGC) with 41.5 m effective absorption path length was utilized to improve the system sensitivity. A self-calibration approach based on direct absorption spectroscopy (DAS) calibrated wavelength modulation spectroscopy (WMS) technique was employed to solve the problem of extra concentration calibration requirement in traditional WMS technique, and to improve the accuracy and stability of the system. According to the Allan deviation analysis, 1-s measurement precision of 0.61 ppmv for DAS and 0.16 ppmv for WMS was obtained, which could be further reduced to 0.11 ppmv for DAS and 0.03 ppmv for WMS by averaging up to 80 s and 50 s, respectively. A week-long continuous atmospheric CH4 concentration measurement was also carried out to demonstrate the long-term performance of our CH4 detection system. With a fast dynamic response characteristics, high-accuracy and high-sensitivity, the proposed detection system is suitable for CH4 measurement in many fields such as atmospheric chemistry analyzation, industrial safety monitoring, agricultural information acquisition, etc.


Assuntos
Lasers , Metano
2.
PLoS One ; 16(9): e0257008, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34478465

RESUMO

In this study, the feasibility of classifying soybean frogeye leaf spot (FLS) is investigated. Leaf images and hyperspectral reflectance data of healthy and FLS diseased soybean leaves were acquired. First, image processing was used to classify FLS to create a reference for subsequent analysis of hyperspectral data. Then, dimensionality reduction methods of hyperspectral data were used to obtain the relevant information pertaining to FLS. Three single methods, namely spectral index (SI), principal component analysis (PCA), and competitive adaptive reweighted sampling (CARS), along with a PCA and SI combined method, were included. PCA was used to select the effective principal components (PCs), and evaluate SIs. Characteristic wavelengths (CWs) were selected using CARS. Finally, the full wavelengths, CWs, effective PCs, SIs, and significant SIs were divided into 14 datasets (DS1-DS14) and used as inputs to build the classification models. Models' performances were evaluated based on the classification accuracy for both the overall and individual classes. Our results suggest that the FLS comprised of five classes based on the proportion of total leaf surface covered with FLS. In the PCA and SI combination model, 5 PCs and 20 SIs with higher weight coefficient of each PC were extracted. For hyperspectral data, 20 CWs and 26 effective PCs were also selected. Out of the 14 datasets, the model input variables provided by five datasets (DS2, DS3, DS4, DS10, and DS11) were more superior than those of full wavelengths (DS1) both in support vector machine (SVM) and least squares support vector machine (LS-SVM) classifiers. The models developed using these five datasets achieved overall accuracies ranging from 91.8% to 94.5% in SVM, and 94.5% to 97.3% in LS-SVM. In addition, they improved the classification accuracies by 0.9% to 3.6% (SVM) and 0.9% to 3.7% (LS-SVM).


Assuntos
Glycine max/ultraestrutura , Processamento de Imagem Assistida por Computador/métodos , Micoses/microbiologia , Doenças das Plantas/microbiologia , Folhas de Planta , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Cercospora , Folhas de Planta/microbiologia , Folhas de Planta/ultraestrutura , Glycine max/microbiologia , Máquina de Vetores de Suporte
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(5): 1291-5, 2016 May.
Artigo em Chinês | MEDLINE | ID: mdl-30000461

RESUMO

According to the principle of mid-infrared absorption spectrum, the fundamental absorption characteristics at the wavelength of 7.5 µm of methane (CH4) molecule was used to design a mid-infrared quantum cascaded laser (QCL) and multi-pass gas cell (MPC)-based methane gas sensor. This sensor uses a thermoelectrically cooled, pulse mode QCL whose central wavelength is 7.5 µm. The QCL wavelength was scanned over CH4 absorption line (1 332.8 cm-1)through adjusting the injection current under the condition of room temperature. Meanwhile, a compact MPC (40 cm long and 800 mL sampling volume) was utilized to achieve an effective optical path length of 16 meters. Additionally, a reference gas cell was occupied and joined a spatial filtering optical structure to meet the requirement of MPC in incidence beam, effectively improved the beam quality, reduced the noise which is caused by the fluctuation of QCL and improved the detection sensitivity of this instrument under the guidance of differential optical absorption spectroscopy method. It indicated that the stability of this instrument is good by means of multiple measurements to the methane gas with different concentration, a detection limit of 1 µmol·mol-1 will be obtained when the signal-to-noise ratio equals 1.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(10): 2851-7, 2014 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-25739237

RESUMO

In order to provide the experiences and references to the researchers who are working on infrared (IR) mixed gas detection field. The proposed manuscript reviews two sections of the aforementioned field, including optical multiplexing structure and detection method. At present, the coherent light sources whose representative are quantum cascade laser (QCL) and inter-band cascade laser(ICL) become the mainstream light source in IR mixed gas detection, which replace the traditional non-coherent light source, such as IR radiation source and IR light emitting diode. In addition, the photon detector which has a super high detectivity and very short response time is gradually beyond thermal infrared detector, dominant in the field of infrared detector. The optical multiplexing structure is the key factor of IR mixed gas detection system, which consists of single light source multi-plexing detection structure and multi light source multiplexing detection structure. Particularly, single light source multiplexing detection structure is advantages of small volume and high integration, which make it a plausible candidate for the portable mixed gas detection system; Meanwhile, multi light source multiplexing detection structure is embodiment of time division multiplex, frequency division multiplexing and wavelength division multiplexing, and become the leading structure of the mixed gas detection system because of its wider spectral range, higher spectral resolution, etc. The detection method applied to IR mixed gas detection includes non-dispersive infrared (NDIR) spectroscopy, wavelength and frequency-modulation spectroscopy, cavity-enhanced spectroscopy and photoacoustic spectroscopy, etc. The IR mixed gas detection system designed by researchers after recognizing the whole sections of the proposed system, which play a significant role in industrial and agricultural production, environmental monitoring, and life science, etc.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(11): 3146-50, 2012 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-23387197

RESUMO

Presented is a compact instrument developed for in situ high-stable and sensitive continuous measurement of trace gases in air, with results shown for ambient methane (CH4) concentration accurate, real-time and in-situ. This instrument takes advantage of recent technology in thermoelectrically cooling (TEC) pulsed Fabry-Perot (FP) quantum cascaded laser (QCL) driving in a pulse mode operating at 7.5 microm ambient temperature to cover a fundamental spectral absorption band near v4 of CH4. A high quality Liquid Nitrogen (LN) cooled Mercury Cadmium Telluride (HgCdTe) mid-infrared (MIR) detector is used along with a total reflection coated gold ellipsoid mirror offering 20 cm single pass optical absorption in an open-path cell to achieve stability of 5.2 x 10(-3) under experimental condition of 200 micromol x mol(-1) measured ambient CH4. The instrument integrated software via time discriminating electronics technology to control QCL provides continuous quantitative trace gas measurements without calibration. The results show that the instrument can be applied to field measurements of gases of environmental concern. Additional, operator could substitute a QCL operating at a different wavelength to measure other gases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...