Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 34(2): e4752, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31756277

RESUMO

A sensitive analytical method was developed and validated for the quantification of cotinine in mouse plasma after exposure to smoke of 0.5, 1.0, and 1.5 commercially available cigarettes, using liquid chromatography tandem mass spectrometry. The method was validated over a linear concentration range of 0.075-20.0 ng/mL with the R2 value being higher than 0.99. Both the precision (coefficient of variation; %) and accuracy (relative error; %) were within acceptable criteria of <15%. The lower limit of quantification (LLOQ) for cotinine was 0.075 ng/mL with sufficient specificity, accuracy, and precision. Following exposure to 0.5, 1.0, and 1.5 cigarette smoke, it was observed that the AUC and the Cmax increased linearly as the doses increased. The pharmacokinetics of cotinine was found linear for the range of 0.5-1.5 commercial cigarette smoke. The quantification of the concentration of cotinine in mouse plasma after smoke exposure will facilitate future behavioral and toxicological experiments in animals and may prove useful in predicting cotinine levels in humans during smoking.


Assuntos
Cotinina/sangue , Cotinina/farmacocinética , Exposição por Inalação/análise , Poluição por Fumaça de Tabaco , Animais , Cotinina/química , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Anal Biochem ; 564-565: 72-79, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30339813

RESUMO

PCK3145 is an anti-metastatic synthetic peptide against prostate cancer. The objective of the study is to develop and validate novel and sensitive methods for the determination of PCK3145 and Pegylated PCK3145 in mouse plasma. An LC-MS/MS method was developed and validated for the determination of PCK3145 giving high sensitivity and linearity in the range of 0.125-4.0 µg/mL. PCK3145 characterised by short half-life, therefore, it was conjugated with the poly ethylene glycol (PEG). However, LC-MS/MS has been more difficult to apply for the quantitative analysis of PEGylated peptides due to the large size. A UHPLC-UV method was developed and validated for the determination of PEG-PCK3145, with linearity of 0.05-2.0 mg/mL. In order to further improve the sensitivity for the detection of PEG-PCK3145, an indirect ELISA method was used. It was found that this method was capable of detecting PCK3145 through the quantification of PEG with excellent sensitivity found at 0.132 ng/mL. The in vitro proteolytic stability of PCK3145 and PEG-PCK3145 in mouse plasma and whole blood was studied by LC-MS/MS and UHPLC, respectively. The LC-MS/MS and ELISA methods can be applied for monitoring levels of PCK3145 in mouse plasma for in vivo pharmacokinetic and bioavailability animal studies.


Assuntos
Cromatografia Líquida/métodos , Fragmentos de Peptídeos/análise , Proteínas Secretadas pela Próstata/análise , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Masculino , Camundongos , Polietilenoglicóis/química
3.
J Pharm Biomed Anal ; 162: 164-170, 2019 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-30243056

RESUMO

Temozolomide (TEMODAL™) (TMZ) is an antineoplastic agent that is primarily used for the treatment of glioblastoma and anaplastic gliomas, two aggressive forms of brain cancer. Due to the poor prognosis of brain tumour patients, there is an increasing body of research into improving the stability and delivery of TMZ past the blood brain barrier using carrier molecules. These require accurate determination of TMZ levels for biodistribution and pharmacokinetic evaluation. Unfortunately, current methodologies for the determination of TMZ in human plasma suffer from low reproducibility, recovery, sensitivity or cost ineffective procedures associated with extensive sample cleaning. To surpass these disadvantages, we developed two bioanalytical methods with high sensitivity and excellent recovery for the determination of TMZ in human plasma at minimum cost. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was used and both methods were validated under US Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) guidelines. The two methods had minor differences in the sample pre-treatment and each method was developed and applied in separate laboratories. Theophylline was selected as internal standard (IS). Calibration curves were linear over the range of 10-500 ng/mL with extraction recovery ranging from 77.3 to 97.3% while all validation parameters met the acceptance criteria and proved the methods' reliability. The validated methods were successfully applied to plasma samples donated from cancer patient following treatment with temozolomide.


Assuntos
Antineoplásicos Alquilantes/sangue , Neoplasias Encefálicas/tratamento farmacológico , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Monitoramento de Medicamentos/métodos , Espectrometria de Massas em Tandem , Temozolomida/sangue , Administração Oral , Antineoplásicos Alquilantes/administração & dosagem , Neoplasias Encefálicas/sangue , Calibragem , Precipitação Química , Cromatografia Líquida de Alta Pressão/normas , Cromatografia de Fase Reversa/normas , Monitoramento de Medicamentos/normas , Humanos , Limite de Detecção , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas , Temozolomida/administração & dosagem
4.
Artigo em Inglês | MEDLINE | ID: mdl-30008308

RESUMO

Sunitinib is an oral FDA/EMEA approved multi-targeted tyrosine kinase inhibitor. It possesses anti-angiogenic and antitumor activity against a variety of advanced solid tumors. However, its chemical core does not allow a potential linkage to tumor-homing elements that could eventually enhance its potency. Therefore, a novel linkable sunitinib derivative, designated SB1, was rationally designed and synthesized. The pharmaceutical profile of SB1 was explored both in vitro and in vivo. Mass spectrometry and NMR spectroscopy were utilized for characterization, while MTT assays and LC-MS/MS validated protocols were used to explore its antiproliferative effect and stability, respectively. Cytotoxicity evaluation in three glioma cells showed that SB1 preserved the antiproliferative effect of sunitinib. SB1 was stable in vitro after 24 h incubation in mouse plasma, while both agents exhibited bioequivalent pharmacokinetic characteristics after i.v. administration in Balb/c mice. To evaluate the levels of SB1 in mouse plasma, a novel analytical method was developed and validated in accordance to the US FDA and the EU EMA guidelines. We formulated a novel linkable sunitinib analog exhibiting similar antiproliferative and apoptotic properties with native sunitinib in glioma cell lines. Both SB1 and native sunitinib showed identical in vitro stability in mouse plasma and pharmacokinetics after i.v. administration in Balb/c mice.


Assuntos
Antineoplásicos/química , Portadores de Fármacos/química , Indóis/química , Pirróis/química , Animais , Antineoplásicos/sangue , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Portadores de Fármacos/análise , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/farmacologia , Estabilidade de Medicamentos , Humanos , Indóis/sangue , Indóis/farmacocinética , Indóis/farmacologia , Modelos Lineares , Camundongos , Camundongos Endogâmicos BALB C , Pirróis/sangue , Pirróis/farmacocinética , Pirróis/farmacologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sunitinibe
5.
Food Chem Toxicol ; 116(Pt B): 147-151, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29653180

RESUMO

Aldehydes are produced in e-cigarette aerosols, as a result of the thermal decomposition of vegetable glycerin, propylene glycerol and flavorings in the atomizer. These aldehydes were collected with derivatization into 2,4-dinitrophenylhydrazine using impinger trapping. A new methodology for simultaneous quantitative analysis of aldehydes in base liquids was developed and validated. Chromatographic separation was carried out on a Jupiter Proteo 90A column, with the mobile phase consisting of 0.1% formic acid in water and acetonitrile, at a flow rate of 0.4 mL/min. Linearity was demonstrated over the range of concentrations 0.025-10 µg/mL, with correlation of determination ≥ 0.999. Intra- and inter-day % relative standard deviation and relative error were ≤ 10%. The lower limit of detection and quantification were 0.008 and 0.025 µg/mL, respectively. This method was further used for the quantification of aldehydes emitted by different base liquids. It has been shown that vegetable glycerin produces the highest percentage of aldehydes after thermal decomposition compared to propylene glycerol. We propose that it can be used for future e-liquids emissions studies.


Assuntos
Aerossóis/química , Aldeídos/análise , Cromatografia Líquida de Alta Pressão/métodos , Sistemas Eletrônicos de Liberação de Nicotina , Espectrofotometria Ultravioleta/métodos , Limite de Detecção , Reprodutibilidade dos Testes
6.
Biomed Chromatogr ; 30(9): 1476-80, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26892539

RESUMO

PCK3145 is a synthetic peptide, derived from the Prostate Secreted Protein 94 (PSP94), with promising in vitro and animal in vivo results in prostate cancer. The aim of the present study was to develop and validate a fast and robust ultra-high-performance liquid chromatography with ultraviolet detection for the determination of PCK3145 in human plasma which would be suitable for the assessment of PCK3145 stability to proteolytic degradation. Following protein precipitation, chromatographic separation was carried out on an Aeris Peptide C18 column with mobile phase consisting of acetonitrile-water at a flow-rate of 0.50 mL/min. The calibration curve was linear over the range 0.50-20.00 µg/mL. Intra- and inter-day percentage relative standard deviation and relative error were ≤10%. The limit of detection and the lower limit of quantification were 0.15 and 0.50 µg/mL, respectively. Recovery of PCK3145 from human plasma was ≥96%. The peptide presented high stability in whole blood and in human plasma (>98% intact peptide after 24 h incubation at 37°C in human plasma), which represents a distinctive advantage in the therapeutic use of the compound. This is the first validated UHPLC method for the determination of PCK3145 reported, and it was successfully applied in the study of the proteolytic stability of PCK3145 in human plasma ex vivo. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fragmentos de Peptídeos/sangue , Proteínas Secretadas pela Próstata/sangue , Espectrofotometria Ultravioleta/métodos , Calibragem , Humanos , Proteólise , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...