Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Comput Assist Radiol Surg ; 6(2): 217-27, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20640603

RESUMO

PURPOSE: Image Guided Surgery (IGS) navigation systems may acquire the position of an instrument relative to the patient with an infrared light-based stereo tracking camera. The measured instrument position is then transformed from the tracking coordinate system to the coordinate system of the intraoperatively acquired medical images. METHOD: A robust and practical automatic method was developed to determine the coordinate transformation from the tracking device to intraoperatively acquired images. The method works with a patient reference device that contains both fluoroscopic markers and tracking markers in a defined geometric arrangement which is fixed on the patient. As precondition the patient reference must be acquired by at least two fluoroscopic images. From the positions of the fluoroscopic markers in these images, the location and orientation is determined and the tracking-to-image transformation is computed. 3D localization of the fluoroscopic reference markers is determined by a three-step process: marker detection, correspondence calculation and triangulation. These steps are implemented in an automatic and robust manner using a new correspondence calculation method. RESULTS: The improved SVD matching method was evaluated experimentally using both synthetic point sets and fluoroscopic marker sets detected from 66 image pairs from a bone and soft tissue phantom acquired by a fluoroscopic c-arm system (Siemens Artis zee Biplane system). For the ideal point sets without outliers 100% of the correspondences were correct. For the noised point sets with up to 20% rogue points 84% correspondence were correct. For lateral translations between the directions of acquisition, the normalized SVD matching method is shown to be as robust as the original approach proposed by Scott and Longuet-Higgins [15]. For other translations, rotations, scaling and shear transformations our method is more robust. The accuracy of the 3D reconstruction approach was also evaluated with a patient phantom. The experiment was repeated with projection images having variant C-arm angulations from 10° to 130°. The results showed that the mean 3D error of the reconstructed markers was 0.36 mm with a standard deviation of 0.096 mm. CONCLUSION: The 3D reconstruction method enables an effective tool to relate a tracking system to a FD-CT imaging system and provide adequate accuracy for most navigation applications.


Assuntos
Óptica e Fotônica/instrumentação , Posicionamento do Paciente , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Instrumentos Cirúrgicos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X , Algoritmos , Fluoroscopia/instrumentação , Humanos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas
2.
Stereotact Funct Neurosurg ; 85(5): 249-55, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17534138

RESUMO

OBJECTIVE: To introduce a new robotic system to the field of neurosurgery and report on a preliminary assessment of accuracy as well as on envisioned application concepts. Based on experience with another system (Evolution 1, URS Inc., Schwerin, Germany), technical advancements are discussed. MATERIAL/METHODS: The basic module is an industrial 6 degrees of freedom robotic arm with a modified control element. The system combines frameless stereotaxy, robotics, and endoscopy. The robotic reproducibility error and the overall error were evaluated. For accuracy testing CT markers were placed on a cadaveric head and pinpointed with the robot's tool tip, both fully automated and telemanipulatory. Applicability in a clinical setting, user friendliness, safety and flexibility were assessed. RESULTS: The new system is suitable for use in the neurosurgical operating theatre. Hard- and software are user-friendly and flexible. The mean reproducibility error was 0.052-0.062 mm, the mean overall error was 0.816 mm. The system is less cumbersome and much easier to use than the Evolution 1. CONCLUSIONS: With its user-friendly interface and reliable safety features, its high application accuracy and flexibility, the new system is a versatile robotic platform for various neurosurgical applications. Adaptations for different applications are currently being realized.


Assuntos
Neurocirurgia/instrumentação , Neurocirurgia/métodos , Salas Cirúrgicas , Robótica/instrumentação , Endoscopia , Desenho de Equipamento , Humanos , Neuronavegação , Imagens de Fantasmas , Equipamentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...