Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38082860

RESUMO

Smartphones enable and facilitate biomedical studies as they allow the recording of various biomedical signals, including photoplethysmograms (PPG). However, user engagement rates in mobile health studies are reduced when an application (app) needs to be installed. This could be alleviated by using installation-free web apps. We evaluate the feasibility of browser-based PPG recording, conducting the first usability study on smartphone-based PPG. We present an at-home study using a web app and library for PPG recording using the rear camera and flash. The underlying library is freely made available to researchers. 25 Android users participated, using their own smartphones. The study consisted of a demographic and anamnestic questionnaire, the signal recording itself (60 s), and a consecutive usability questionnaire. After filtering, heart rate was extracted (14/17 successful), signal-to-noise ratios assessed (0.64 ± 0.50 dB, mean ± standard deviation), and quality was visually inspected (12/17 usable for diagnosis). Recording was not supported in 9 cases. This was due to the browser's insufficient support for the flash light API. The app received a System Usability Scale score of 82 ± 9, which is above the 90th percentile. Overall, browser flash light support is the main limiting factor for broad device support. Thus, browser-based PPG is not yet widely applicable, although most participants feel comfortable with the recording itself. The utilization of the user-facing camera might represent a more promising approach. This study contributes to the development of low-barrier, user-friendly, installation-free smartphone signal acquisition. This enables profound, comprehensive data collection for research and clinical practice.Clinical relevance- WebPPG offers low-barrier remote diagnostic capabilities without the need for app installation.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Fotopletismografia , Estudos de Viabilidade , Inquéritos e Questionários
2.
JMIR Pediatr Parent ; 6: e50765, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38109377

RESUMO

Background: Although digital maternity records (DMRs) have been evaluated in the past, no previous work investigated usability or acceptance through an observational usability study. Objective: The primary objective was to assess the usability and perception of a DMR smartphone app for pregnant women. The secondary objective was to assess personal preferences and habits related to online information searching, wearable data presentation and interpretation, at-home examination, and sharing data for research purposes during pregnancy. Methods: A DMR smartphone app was developed. Key features such as wearable device integration, study functionalities (eg, questionnaires), and common pregnancy app functionalities (eg, mood tracker) were included. Women who had previously given birth were invited to participate. Participants completed 10 tasks while asked to think aloud. Sessions were conducted via Zoom. Video, audio, and the shared screen were recorded for analysis. Task completion times, task success, errors, and self-reported (free text) feedback were evaluated. Usability was measured through the System Usability Scale (SUS) and User Experience Questionnaire (UEQ). Semistructured interviews were conducted to explore the secondary objective. Results: A total of 11 participants (mean age 34.6, SD 2.2 years) were included in the study. A mean SUS score of 79.09 (SD 18.38) was achieved. The app was rated "above average" in 4 of 6 UEQ categories. Sixteen unique features were requested. We found that 5 of 11 participants would only use wearables during pregnancy if requested to by their physician, while 10 of 11 stated they would share their data for research purposes. Conclusions: Pregnant women rely on their medical caregivers for advice, including on the use of mobile and ubiquitous health technology. Clear benefits must be communicated if issuing wearable devices to pregnant women. Participants that experienced pregnancy complications in the past were overall more open toward the use of wearable devices in pregnancy. Pregnant women have different opinions regarding access to, interpretation of, and reactions to alerts based on wearable data. Future work should investigate personalized concepts covering these aspects.

3.
J Clin Med ; 12(13)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37445258

RESUMO

BACKGROUND AND OBJECTIVES: Mobile and remote ultrasound devices are becoming increasingly available. The benefits and possible risks of self-guided ultrasound examinations conducted by pregnant women at home have not yet been well explored. This study investigated aspects of feasibility and acceptance, as well as the success rates of such examinations. METHODS: In this prospective, single-center, interventional study, forty-six women with singleton pregnancies between 17 + 0 and 29 + 6 weeks of gestation were included in two cohorts, using two different mobile ultrasound systems. The participants examined the fetal heartbeat, fetal profile and amniotic fluid. Aspects of feasibility and acceptance were evaluated using a questionnaire. Success rates in relation to image and video quality were evaluated by healthcare professionals. RESULTS: Two thirds of the women were able to imagine performing the self-guided examination at home, but 87.0% would prefer live support by a professional. Concerns about their own safety and that of the child were expressed by 23.9% of the women. Success rates for locating the target structure were 52.2% for videos of the fetal heartbeat, 52.2% for videos of the amniotic fluid in all four quadrants and 17.9% for videos of the fetal profile. CONCLUSION: These results show wide acceptance of self-examination using mobile systems for fetal ultrasonography during pregnancy. Image quality was adequate for assessing the amniotic fluid and fetal heartbeat in most participants. Further studies are needed to determine whether ultrasound self-examinations can be implemented in prenatal care and how this would affect the fetomaternal outcome.

4.
JMIR Form Res ; 6(3): e33635, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35230250

RESUMO

BACKGROUND: Fitness trackers and smart watches are frequently used to collect data in longitudinal medical studies. They allow continuous recording in real-life settings, potentially revealing previously uncaptured variabilities of biophysiological parameters and diseases. Adequate device accuracy is a prerequisite for meaningful research. OBJECTIVE: This study aims to assess the heart rate recording accuracy in two previously unvalidated devices: Fitbit Charge 4 and Samsung Galaxy Watch Active2. METHODS: Participants performed a study protocol comprising 5 resting and sedentary, 2 low-intensity, and 3 high-intensity exercise phases, lasting an average of 19 minutes 27 seconds. Participants wore two wearables simultaneously during all activities: Fitbit Charge 4 and Samsung Galaxy Watch Active2. Reference heart rate data were recorded using a medically certified Holter electrocardiogram. The data of the reference and evaluated devices were synchronized and compared at 1-second intervals. The mean, mean absolute error, mean absolute percentage error, Lin concordance correlation coefficient, Pearson correlation coefficient, and Bland-Altman plots were analyzed. RESULTS: A total of 23 healthy adults (mean age 24.2, SD 4.6 years) participated in our study. Overall, and across all activities, the Fitbit Charge 4 slightly underestimated the heart rate, whereas the Samsung Galaxy Watch Active2 overestimated it (-1.66 beats per minute [bpm]/3.84 bpm). The Fitbit Charge 4 achieved a lower mean absolute error during resting and sedentary activities (seated rest: 7.8 vs 9.4; typing: 8.1 vs 11.6; laying down [left]: 7.2 vs 9.4; laying down [back]: 6.0 vs 8.6; and walking slowly: 6.8 vs 7.7 bpm), whereas the Samsung Galaxy Watch Active2 performed better during and after low- and high-intensity activities (standing up: 12.3 vs 9.0; walking fast: 6.1 vs 5.8; stairs: 8.8 vs 6.9; squats: 15.7 vs 6.1; resting: 9.6 vs 5.6 bpm). CONCLUSIONS: Device accuracy varied with activity. Overall, both devices achieved a mean absolute percentage error of just <10%. Thus, they were considered to produce valid results based on the limits established by previous work in the field. Neither device reached sufficient accuracy during seated rest or keyboard typing. Thus, both devices may be eligible for use in respective studies; however, researchers should consider their individual study requirements.

5.
Front Plant Sci ; 9: 430, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29740457

RESUMO

The best characterized function of sucrose transporters of the SUC family in plants is the uptake of sucrose into the phloem for long-distance transport of photoassimilates. This important step is usually performed by one specific SUC in every species. However, plants possess small families of several different SUCs which are less well understood. Here, we report on the characterization of AtSUC6 and AtSUC7, two members of the SUC family in Arabidopsis thaliana. Heterologous expression in yeast (Saccharomyces cerevisiae) revealed that AtSUC6Col-0 is a high-affinity H+-symporter that mediates the uptake of sucrose and maltose across the plasma membrane at exceptionally low pH values. Reporter gene analyses revealed a strong expression of AtSUC6Col-0 in reproductive tissues, where the protein product might contribute to sugar uptake into pollen tubes and synergid cells. A knockout of AtSUC6 did not interfere with vegetative development or reproduction, which points toward physiological redundancy of AtSUC6Col-0 with other sugar transporters. Reporter gene analyses showed that AtSUC7Col-0 is expressed in roots and pollen tubes and that this sink specific expression of AtSUC7Col-0 is regulated by intragenic regions. Transport activity of AtSUC7Col-0 could not be analyzed in baker's yeast or Xenopus oocytes because the protein was not correctly targeted to the plasma membrane in both heterologous expression systems. Therefore, a novel approach to analyze sucrose transporters in planta was developed. Plasma membrane localized SUCs including AtSUC6Col-0 and also sucrose specific SWEETs were able to mediate transport of the fluorescent sucrose analog esculin in transformed mesophyll protoplasts. In contrast, AtSUC7Col-0 is not able to mediate esculin transport across the plasma membrane which implicates that AtSUC7Col-0 might be a non-functional pseudogene. The novel protoplast assay provides a useful tool for the quick and quantitative analysis of sucrose transporters in an in planta expression system.

6.
Front Plant Sci ; 5: 37, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24600457

RESUMO

Post-translational protein modification plays a pivotal role in the regulation and specific turnover of proteins. One of these important modifications is the ubiquitination of target proteins, which can occur at distinct cellular compartments. At the plasma membrane, ubiquitination regulates the internalization and thus trafficking of membrane proteins such as receptors and channels. The Arabidopsis plant U-box (PUB) armadillo repeat (PUB-ARM) ubiquitin ligase SAUL1 (SENESCENCE-ASSOCIATED UBIQUITIN LIGASE1) is part of the ubiquitination machinery at the plasma membrane. In contrast to most other PUB-ARM proteins, SAUL1 carries additional C-terminal ARM repeats responsible for plasma membrane-association. Here, we demonstrated that the C-terminal ARM repeat domain is also essential and sufficient to mediate plasma membrane-association of the closest Arabidopis paralog AtPUB43. We investigated targeting of PUB-ARM ubiquitin ligases of different plant species to find out whether plasma membrane-association of SAUL1-type PUB-ARM proteins is conserved. Phylogenetic analysis identified orthologs of SAUL1 in these plant species. Intracellular localization of transiently expressed GFP fusion proteins revealed that indeed plasma membrane-association due to additional C-terminal ARM repeats represents a conserved feature of SAUL1-type proteins. Analyses of transgenic Arabidopsis plants overexpressing N-terminally masked or truncated proteins revealed that interfering with the function of SAUL1-type proteins resulted in severe growth defects. Our results suggest an ancient origin of ubiquitination at the plasma membrane in the evolution of land plants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...