1.
Kobe J Med Sci ; 53(6): 297-304, 2008 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-18762724

RESUMO

This study tested whether once weekly instillation of latanoprost exerts the similar IOP lowering effect as once daily instillation in the same individuals. Latanoprost was administered on right eyes of eight healthy male volunteers once daily first for 24 days, which was followed by the 31-day washout and the subsequent once weekly instillation for another 24 days. The mean baseline IOP was 12.06 +/- 1.50 (range, 10.0 to 14.0) mmHg, whereas the mean IOP during once daily treatment was 9.87 +/- 1.71 mmHg, which was significantly lower than the former (p=0.025). The mean washout IOP was 12.56 +/- 2.16 mmHg, which was similar to the baseline IOP. The mean IOP during once weekly instillation of latanoprost was 11.34 +/- 1.51 mmHg, which was not statistically different from the washout IOP. Four of the 8 subjects showed 15% or more reduction in IOP both during once daily and once weekly instillations, two of whom were overlapped. Since the magnitude of the IOP reduction with once daily use was higher than that with once weekly use even in the responders, the current protocol of once daily instillation should be respected.


Assuntos
Saúde , Pressão Intraocular/efeitos dos fármacos , Prostaglandinas F Sintéticas/administração & dosagem , Prostaglandinas F Sintéticas/farmacologia , Adulto , Esquema de Medicação , Humanos , Latanoprosta , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Fatores de Tempo
2.
Am J Ophthalmol ; 142(2): 332-4, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16876523

RESUMO

PURPOSE: To evaluate the agreement of iCare rebound tonometer in measuring intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), Tonopen XL, and noncontact tonometer, and the influence of the central corneal thickness (CCT) on IOP measurements made with these four tonometers in 45 (12 control and 33 glaucomatous or ocular hypertensive) eyes. DESIGN: Clinically relevant experimental study. METHODS: Tonometer intermethod agreement was assessed by the Bland-Altman method. The relations of CCT with absolute IOP values and intertonometer differences were analyzed by linear regression. RESULTS: The mean differences (95% limits of agreement) in IOP readings between iCare and GAT, Tonopen XL, and noncontact tonometer were 1.40 +/- 4.29, 0.00 +/- 4.78, and 2.22 +/- 4.19 mm Hg, respectively. All tonometries had a marked association with CCT. As the CCT got thicker, iCare considerably overestimated GAT and Tonopen XL. CONCLUSIONS: Although influenced by CCT, iCare agrees well with applanation tonometers.


Assuntos
Glaucoma/fisiopatologia , Pressão Intraocular/fisiologia , Tonometria Ocular/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Córnea/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Reprodutibilidade dos Testes , Tonometria Ocular/instrumentação