Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sex Transm Dis ; 29(10): 576-80, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12370524

RESUMO

BACKGROUND: A previous study demonstrated that Digene's Hybrid Capture 2 (HC2) DNA tests for detection of and (CT/GC) could be performed using cervical swab specimens collected in GenProbe transport media with significantly greater sensitivity for the detection of than with the GenProbe PACE 2 system. GOAL: The goal was to assess the performance of HC2 tests in comparison with GenProbe PACE 2 tests for the detection of CT/GC in male urethral swab specimens. STUDY DESIGN: A total of 1,202 male urethral swab specimens were collected in GenProbe PACE transport medium. All specimens were first tested with the PACE 2 system, followed by masked HC2 CT/GC testing. The GenProbe AMPLIFIED CT Assay (AMP CT) and PCR/SHARP Signal System (SHARP) were used for adjudication of discrepant results. RESULTS: The prevalence rates for this population were 8.4% for and 14.6% for, based on the adjudicated results. The relative sensitivity and specificity for the detection of were 97.0% and 99.8% for HC2 and 69.3% and 98.3% for PACE 2, respectively. The relative sensitivities for the detection of were 98.9% for HC2 and 99.4% for PACE 2, with the same specificity of 99.9% for both tests. Agreement between the two testing methods was 95.4% for and 99.6% for. CONCLUSION: The HC2 test is compatible with the GenProbe collection medium, with significantly greater sensitivity than the GenProbe PACE 2 test for detecting and similar sensitivities for detecting.


Assuntos
Chlamydia trachomatis/isolamento & purificação , Sondas de DNA , DNA Bacteriano/análise , Neisseria gonorrhoeae/isolamento & purificação , Uretrite/microbiologia , Chlamydia trachomatis/genética , Humanos , Masculino , Neisseria gonorrhoeae/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Sensibilidade e Especificidade
2.
J Clin Microbiol ; 40(2): 641-4, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11825985

RESUMO

Digene's Hybrid Capture 2 (HC2) CT/GC, CT-ID, and GC-ID DNA tests were evaluated by comparison to traditional culture methods for detecting Chlamydia trachomatis and Neisseria gonorrhoeae infections in 669 cervical specimens from high-risk female populations attending two sexually transmitted disease clinics. For detection of either or both infections, the HC2 CT/GC test algorithm had 93.8% sensitivity and 95.9% specificity compared to those of culture. After resolution of discrepant results by direct fluorescent-antibody (DFA) staining or PCR assay, the relative sensitivity and specificity of the HC2 CT/GC test algorithm increased to 94.8 and 99.8%, while the values for culture were 83.6% (McNemar's P value, 0.0062) and 100%, respectively. For detection of the individual pathogens, the relative sensitivities for the HC2 CT-ID and GC-ID tests were 97.2 and 92.2% and the specificities were greater than 99% compared to culture adjucated by DFA staining and PCR. Test performance varied at the two clinics: the HC2 CT/GC algorithm, CT-ID, and GC-ID tests had significantly higher sensitivities (McNemar's P value, <0.05) than that of culture for the population at one clinic as well as for the combined populations. At the other clinic, the HC2 tests performed as well as culture.


Assuntos
Colo do Útero/microbiologia , Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/isolamento & purificação , Gonorreia/diagnóstico , Neisseria gonorrhoeae/isolamento & purificação , Reação em Cadeia da Polimerase , Algoritmos , Infecções por Chlamydia/microbiologia , Chlamydia trachomatis/genética , Meios de Cultura , Feminino , Técnica Direta de Fluorescência para Anticorpo , Gonorreia/microbiologia , Humanos , Medições Luminescentes , Neisseria gonorrhoeae/genética , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...