1.
Heart Rhythm ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38848856

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden. OBJECTIVE: Limiting ablation within post-infarct scar to conduction channels within the scar to reduce VT recurrence. METHODS: Patients undergoing catheter ablation for recurrent implantable defibrillator (ICD) therapy for post-infarct VT were recruited at 5 centres. Left ventricular maps were collected on CARTO™ using a Pentaray™ catheter. Ripple mapping was used to categorise infarct scar potentials (SPs) by timing. Earliest SPs were ablated sequentially until there was loss of the terminal scar potentials without their direct ablation. The primary outcome measure was sustained VT episodes as documented by device interrogations at 1yr and was compared with VT episodes in the year pre-ablation. RESULTS: 50 pts were recruited (mean LVEF 33%±9) and 37pts (74%) met channel ablation endpoint with successful loss of latest SPs without direct ablation. There were 16 recurrences during 1yr follow up. There was a 90% reduction in VT burden from 30.2±53.9 to 3.1±7.5 (p<0.01) per patient, with a concomitant 88% reduction in appropriate shocks from 2.1±2.7 to 0.2±0.9 (p<0.01). There were 8 deaths during follow-up. Those who met channel ablation endpoint had no significant difference in mortality, recurrence or VT burden but had a significantly lower ablation burden 25.7±4.2 vs 39.9±6.1 mins (p=0.001). CONCLUSION: Scar channel ablation is feasible using ripple mapping and can be an alternative to more extensive substrate modification techniques.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38478165

RESUMO

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

3.
Heart Rhythm ; 21(5): 571-580, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286246

RESUMO

BACKGROUND: Three-dimensional (3D) mapping of the ventricular conduction system is challenging. OBJECTIVE: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV). METHODS: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation. Ripple maps were viewed from the end of the P wave to QRS onset in 1-ms increments. Clusters of >3 ripple bars were interrogated for the presence of Purkinje potentials, which were tagged on the 3D geometry. Repeating this process allowed conduction system delineation. RESULTS: Maps were reviewed in 24 patients (mean 3112 ± 613 points). There were 150.9 ± 24.5 Purkinje potentials per map, at the left posterior fascicle (LPF) in 22 patients (92%) and at the left anterior fascicle (LAF) in 15 patients (63%). The LAF was shorter (41.4 vs 68.8 mm; P = .0005) and activated for a shorter duration (40.6 vs 64.9 ms; P = .002) than the LPF. Fourteen of 24 patients had left bundle branch block (LBBB), with 11 of 14 (78%) having Purkinje potential-associated breakout. There were fewer breakouts from the conduction system during LBBB (1.8 vs 3.4; 1.6 ± 0.6; P = .039) and an inverse correlation between breakout sites and QRS duration (P = .0035). CONCLUSION: We applied ripple mapping to present a detailed electroanatomic characterization of the conduction system in the postinfarct LV. Patients with broader QRS had fewer LV breakout sites from the conduction system. However, there was 3D mapping evidence of LV breakout from an intact conduction system in the majority of patients with LBBB.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco , Ventrículos do Coração , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Masculino , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Ablação por Cateter/métodos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/complicações , Eletrocardiografia , Ramos Subendocárdicos/fisiopatologia , Idoso , Imageamento Tridimensional , Mapeamento Potencial de Superfície Corporal/métodos
5.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37738643

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Reino Unido , Recidiva
6.
J Innov Card Rhythm Manag ; 14(5): 5442-5450, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37216082

RESUMO

The learning curve for the novel RHYTHMIA HDx™ 3-dimensional electroanatomic system is unknown. Retrospective data collection was carried out at 3 U.K. centers from the introduction of RHYTHMIA HDx™ (Boston Scientific, Marlborough, MA, USA) and associated mapping and ablation catheters. Patients were matched with controls using the CARTO® 3 mapping system (Biosense Webster Inc., Diamond Bar, CA, USA). Fluoroscopy, radiofrequency ablation, and procedure times; acute and long-term success; and complications were assessed. A total of 253 study patients along with 253 controls were included. Significant correlations existed between procedural efficiency metrics and center experience for de novo atrial fibrillation (AF) ablation (procedure time, Spearman's ρ = -0.624; ablation time, ρ = -0.795; both P < .0005) and de novo atrial flutter (AFL) ablation (ablation time, ρ = -0.566; fluoroscopy time, ρ = -0.520; both P = .001). No correlations existed for other assessed atrial arrhythmias. For de novo AF and AFL, metrics significantly improved after 10 procedures in each center (procedure time [AF only, P = .001], ablation time [AF, P < .0005; AFL, P < .0005], and fluoroscopy time [AFL only, P = .0022]) and became comparable to those of controls. Acute success and long-term success did not experience significant improvements with experience, but they were comparable to the control group throughout. Complications with RHYTHMIA HDx™ were comparable to those associated with CARTO® 3. In conclusion, a short learning curve exists with the use of RHYTHMIA HDx™ for standardized procedures (de novo AF/AFL). Procedural performance improved and became comparable to that seen with CARTO® 3 following 10 cases at each center. Clinical outcomes at 6 and 12 months and complications were no different from those observed in controls.

7.
Heart ; 109(5): 364-371, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36396438

RESUMO

OBJECTIVE: We aimed to compare cryoballoon pulmonary vein isolation (PVI) with standard radiofrequency cavotricuspid isthmus (CTI) ablation as first-line treatment for typical atrial flutter (AFL). METHODS: Cryoballoon Pulmonary Vein Isolation as First-Line Treatment for Typical Atrial Flutter was an international, multicentre, open with blinded assessment trial. Patients with CTI-dependent AFL and no documented atrial fibrillation (AF) were randomised to either cryoballoon PVI alone or radiofrequency CTI ablation. Primary efficacy outcome was time to first recurrence of sustained (>30 s) symptomatic atrial arrhythmia (AF/AFL/atrial tachycardia) at 12 months as assessed by continuous monitoring with an implantable loop recorder. Primary safety outcome was a composite of death, stroke, tamponade requiring drainage, atrio-oesophageal fistula, pacemaker implantation, serious vascular complications or persistent phrenic nerve palsy. RESULTS: Trial recruitment was halted at 113 of the target 130 patients because of the SARS-CoV-2 pandemic (PVI, n=59; CTI ablation, n=54). Median age was 66 (IQR 61-71) years, with 98 (86.7%) men. At 12 months, the primary outcome occurred in 11 (18.6%) patients in the PVI group and 9 (16.7%) patients in the CTI group. There was no significant difference in the primary efficacy outcome between the groups (HR 1.11, 95% CI 0.46 to 2.67). AFL recurred in six (10.2%) patients in the PVI arm and one (1.9%) patient in the CTI arm (p=0.116). Time to occurrence of AF of ≥2 min was significantly reduced with cryoballoon PVI (HR 0.46, 95% CI 0.25 to 0.85). The composite safety outcome occurred in four patients in the PVI arm and three patients in the CTI arm (p=1.000). CONCLUSION: Cryoballoon PVI as first-line treatment for AFL is equally effective compared with standard CTI ablation for preventing recurrence of atrial arrhythmia and better at preventing new-onset AF. TRIAL REGISTRATION NUMBER: NCT03401099.


Assuntos
Fibrilação Atrial , Flutter Atrial , COVID-19 , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Idoso , Feminino , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/epidemiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , COVID-19/complicações , SARS-CoV-2 , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Recidiva
8.
JACC Clin Electrophysiol ; 8(5): 595-604, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35589172

RESUMO

OBJECTIVES: This analysis was performed to evaluate the transition of local impedance (LI) drop during pulmonary vein isolation (PVI) to durable block and mature lesion formation based on 3-month mapping procedures. BACKGROUND: A radiofrequency catheter measuring LI has been shown to be effective for performing PVI in patients with paroxysmal atrial fibrillation. Previous analysis has demonstrated LI drop to be predictive of pulmonary vein segment conduction block during an atrial fibrillation ablation procedure. METHODS: Fifty-eight patients who had undergone LI-blinded de novo PVI returned for a 3-month mapping procedure. PVI ablation circles were divided into 16 anatomic segments for classification (durable block or gap), and the median LI drop within segments with an interlesion distance of ≤6 mm was compared. A total of 51 data sets met the criteria for segmental analysis of LI performance. RESULTS: At the 3-month procedure, PV connection was confirmed in at least 1 PV segment in 35 of the included patients. LI drop outperformed generator impedance drop as a predictor of durable conduction block (area under the receiver-operating characteristic curve: 0.79 vs 0.68; P = 0.003). Optimal LI drops were identified by left atrial region (anterior/superior: 16.9 Ω [sensitivity: 69.1%; specificity: 85.0%; positive predictive value for durable conduction block: 97.7%]; posterior/inferior:14.2 Ω [sensitivity: 73.8%; specificity: 78.3%; positive predictive value: 96.9%]). Starting LI before radiofrequency (RF) application was significantly different among healthy, gap, and mature scar tissue and was also a contributing factor to achieving an optimal LI drop (85.2% of RF applications with a starting LI of ≥110 Ω achieved the optimal regional drop or greater). CONCLUSIONS: LI drop is predictive of durable PV segment isolation. Preablation starting LI is associated with the magnitude of LI drop. These findings suggest that a regional approach to RF ablation guided by LI combined with careful interlesion distance control may be beneficial in patients with paroxysmal atrial fibrillation (Electrical Coupling Information From the Rhythmia HDx System and DirectSense Technology in Subjects With Paroxysmal Atrial Fibrillation [LOCALIZE]; NCT03232645).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Impedância Elétrica , Bloqueio Cardíaco/cirurgia , Humanos , Veias Pulmonares/cirurgia
9.
BMJ Open ; 12(1): e059527, 2022 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-34980634

RESUMO

INTRODUCTION: The purpose of this study is to assess the ability of two new ECG markers (Regional Repolarisation Instability Index (R2I2) and Peak Electrical Restitution Slope) to predict sudden cardiac death (SCD) or ventricular arrhythmia (VA) events in patients with ischaemic cardiomyopathy undergoing implantation of an implantable cardioverter defibrillator for primary prevention indication. METHODS AND ANALYSIS: Multicentre Investigation of Novel Electrocardiogram Risk markers in Ventricular Arrhythmia prediction is a prospective, open label, single blinded, multicentre observational study to establish the efficacy of two ECG biomarkers in predicting VA risk. 440 participants with ischaemic cardiomyopathy undergoing routine first time implantable cardioverter-defibrillator (ICD) implantation for primary prevention indication are currently being recruited. An electrophysiological (EP) study is performed using a non-invasive programmed electrical stimulation protocol via the implanted device. All participants will undergo the EP study hence no randomisation is required. Participants will be followed up over a minimum of 18 months and up to 3 years. The first patient was recruited in August 2016 and the study will be completed at the final participant follow-up visit. The primary endpoint is ventricular fibrillation or sustained ventricular tachycardia >200 beats/min as recorded by the ICD. The secondary endpoint is SCD. Analysis of the ECG data obtained during the EP study will be performed by the core lab where blinding of patient health status and endpoints will be maintained. ETHICS AND DISSEMINATION: Ethical approval has been granted by Research Ethics Committees Northern Ireland (reference no. 16/NI/0069). The results will inform the design of a definitive Randomised Controlled Trial (RCT). Dissemination will include peer reviewed journal articles reporting the qualitative and quantitative results, as well as presentations at conferences and lay summaries. TRIAL REGISTRATION NUMBER: NCT03022487.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Humanos , Reino Unido
10.
Europace ; 23(7): 1042-1051, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33550380

RESUMO

AIMS: Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). METHODS AND RESULTS: Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance ≤6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance ≤6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1-27.1) Ω] compared with segments with gaps [10.6 (7.8-14.7) Ω, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Ω (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Ω (positive predictive value for block: 98.1%) where inter-lesion distances were ≤6 mm. CONCLUSION: The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Impedância Elétrica , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
11.
J Interv Card Electrophysiol ; 60(3): 427-432, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32385774

RESUMO

PURPOSE: Treatment of typical atrial flutter (AFL) with cavo-tricuspid isthmus (CTI) ablation is associated with a high occurrence rate of new onset atrial fibrillation (AF) during follow-up. There are data to support the addition of pulmonary vein isolation (PVI) to CTI ablation in patients with both AF and AFL, but the role of cryoballoon PVI only, with no CTI ablation, in AFL patients with no prior documentation of AF has not been studied. METHODS: CRAFT is an international, prospective, randomised, open with blinded assessment, multicentre superiority study comparing radiofrequency CTI ablation and cryoballoon PVI in patients with typical AFL. Participants with typical AFL are randomised in a 1:1 ratio to either treatment arm, with patients randomised to PVI not receiving CTI ablation. Post-procedural cardiac monitoring is performed using an implantable loop recorder. The primary endpoint is time to first recurrence of sustained symptomatic atrial arrhythmia. Key secondary endpoints include (1) total arrhythmia burden at 12 months, (2) time to first episode of AF lasting ≥ 2 min, (3) time to recurrence of AFL or AT and (4) procedural and fluoroscopy times. The primary safety endpoint is the composite of death, stroke/transient ischaemic attack, cardiac tamponade requiring drainage, atrio-oesophageal fistula, requirement for a permanent pacemaker, serious vascular complications requiring intervention or delaying discharge and persistent phrenic nerve palsy lasting > 24 h. CONCLUSION: This study compares the outcomes of 2 different approaches to typical AFL-the conventional 'substrate'-based strategy of radiofrequency CTI ablation versus a novel 'trigger'-based strategy of cryoballoon PVI. TRIAL REGISTRATION: ( ClinicalTrials.gov ID: NCT03401099 ).


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
12.
J Interv Card Electrophysiol ; 58(1): 9-19, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31197583

RESUMO

PURPOSE: Adverse left atrial (LA) remodeling is known to be associated with persistent atrial fibrillation (PeAF). The time course and pattern of reversal of LA remodeling following catheter ablation is poorly understood. We aimed to evaluate LA chamber volumes and dimensions, LA conduction velocities, and LA bipolar voltages at baseline and at 2 months after catheter ablation for PeAF. METHODS: Twenty-three patients with PeAF underwent detailed LA mapping during fixed rate atrial pacing using the CARTO3 navigation system prior to undergoing pulmonary vein isolation. All patients returned for protocol-mandated repeat electrophysiology study at 2 months, irrespective of symptoms or arrhythmia recurrence, during which all measurements were repeated using an identical mapping protocol. Patients then underwent daily ECG monitoring for 12 months. RESULTS: Nineteen out of twenty-three (83.6%) patients had durable PVI of all veins at repeat electrophysiology study, while 4 (17.4%) patients had late reconnection of a single vein each. In the blinded offline analysis, LA volume at follow-up was significantly lower as compared with baseline (55 ± 14 mL/m2 vs. 65 ± 15 mL/m2, P < 0.001). LA conduction velocities were significantly greater at 2 months (0.90 ± 0.13 m/s vs. 0.78 ± 0.13 m/s, P = 0.01). There was non-uniform regional LA voltage evolution, with a significant increase in bipolar voltages observed on the LA posterior wall (2.18 ± 0.85 mV vs. 1.83 ± 0.49 mV, P = 0.04), but not elsewhere. Individual variables of remodeling were not associated with AF recurrence. CONCLUSION: Significant structural and electrical reverse remodeling of the LA can be seen as early as 2 months following successful catheter ablation for PeAF.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
PLoS One ; 14(6): e0217875, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31170231

RESUMO

BACKGROUND: Although QRS duration (QRSd) is an important determinant of cardiac resynchronization therapy (CRT) response, non-responder rates remain high. QRS fragmentation can also reflect electrical dyssynchrony. We hypothesized that quantification of abnormal QRS peaks (QRSp) would predict CRT response. METHODS: Forty-seven CRT patients (left ventricular ejection fraction = 23±7%) were prospectively studied. Digital 12-lead ECGs were recorded during native rhythm at baseline and 6 months post-CRT. For each precordial lead, QRSp was defined as the total number of peaks detected on the unfiltered QRS minus those detected on a smoothed moving average template QRS. CRT response was defined as >5% increase in left ventricular ejection fraction post-CRT. RESULTS: Sixty-percent of patients responded to CRT. Baseline QRSd was similar in CRT responders and non-responders, and did not change post-CRT regardless of response. Baseline QRSp was greater in responders than non-responders (9.1±3.5 vs. 5.9±2.2, p = 0.001) and decreased in responders (9.2±3.6 vs. 7.9±2.8, p = 0.03) but increased in non-responders (5.5±2.3 vs. 7.5±2.8, p = 0.049) post-CRT. In multivariable analysis, QRSp was the only independent predictor of CRT response (Odds Ratio [95% Confidence Interval]: 1.5 [1.1-2.1], p = 0.01). ROC analysis revealed QRSp (area under curve = 0.80) to better discriminate response than QRSd (area under curve = 0.67). Compared to QRSd ≥150ms, QRSp ≥7 identified response with similar sensitivity but greater specificity (74 vs. 32%, p<0.05). Amongst patients with QRSd <150ms, more patients with QRSp ≥7 responded than those with QRSp <7 (75 vs. 0%, p<0.05). CONCLUSIONS: Our novel automated QRSp metric independently predicts CRT response and decreases in responders. Electrical dyssynchrony assessed by QRSp may improve CRT selection and track structural remodeling, especially in those with QRSd <150ms.


Assuntos
Terapia de Ressincronização Cardíaca , Eletrocardiografia , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC
14.
Circ Arrhythm Electrophysiol ; 11(9): e006576, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354288

RESUMO

Background Catheter ablation for persistent atrial fibrillation (AF) is associated with less favorable outcomes than for paroxysmal AF. Substrate modification is often added to pulmonary vein isolation (PVI) to try to improve success rates. Recent studies have shown improved clinical outcomes with use of regional ablation index (AI) targets for PVI. We hypothesized that prospective use of AI-guided PVI in persistent AF patients would result in a low rate of PV reconnection at repeat electrophysiology study and that a high success rate can be achieved with durable PVI alone. Methods Forty consecutive patients with persistent AF underwent AI-guided PVI with target values of 550 for anterior and 400 for posterior left atrial regions, followed by a protocol-mandated repeat procedure after 2 months. Patients were monitored for atrial tachyarrhythmia recurrence via daily plus symptom-initiated ECG recordings for 12 months. Recurrence was defined as ≥30 seconds of any atrial tachyarrhythmia after a 3-month blanking period. Results PV reconnection was seen at repeat electrophysiology study in 22% of patients, affecting 7% of PVs. Ablation on the intervenous carina was required in 44% patients to achieve durable PVI. Atrial tachyarrhythmia recurrence was documented in 8 (20%) patients, only one of whom had PV reconnection at repeat study. At 12 months, 38/40 (95%) patients were in sinus rhythm, with 4 (10%) patients having started antiarrhythmic drugs. Higher body mass index and excess alcohol consumption were the only significant factors associated with atrial tachyarrhythmia recurrence. Conclusions Use of AI targets results in a high level of durable PVI. A good clinical outcome can be achieved in the great majority of persistent AF patients with AI-guided PVI alone. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02628730.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Consumo de Bebidas Alcoólicas/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Europa (Continente) , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo
15.
J Cardiovasc Electrophysiol ; 29(6): 881-888, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29505684

RESUMO

INTRODUCTION: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. METHODS AND RESULTS: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). CONCLUSION: Application of the TPI filter to ConfiDENSE maps significantly increases the quality of the voltage data, conserving a reasonable point density, but still overestimates low voltage points as compared to CF-sensing maps or maps reviewed manually.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Eletrodos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo
17.
Artigo em Inglês | MEDLINE | ID: mdl-28705874

RESUMO

BACKGROUND: Cardiomyopathy patients are at risk of sudden death, typically from scar-related abnormalities of electrical activation that promote ventricular tachyarrhythmias. Abnormal intra-QRS peaks may provide a measure of altered activation. We hypothesized that quantification of such QRS peaks (QRSp) in high-resolution ECGs would predict arrhythmic events in implantable cardioverter-defibrillator (ICD)-eligible cardiomyopathy patients. METHODS AND RESULTS: Ninety-nine patients with ischemic or non-ischemic dilated cardiomyopathy undergoing prophylactic ICD implantation were prospectively enrolled (age 62±11 years, left ventricular ejection fraction 27±7%). High-resolution (1024 Hz) digital 12-lead ECGs were recorded during intrinsic rhythm. QRSp was quantified for each precordial lead as the total number of low-amplitude deflections that deviated from their respective naive QRS template. The primary end point of arrhythmic events was defined as appropriate ICD therapy or sustained ventricular tachyarrhythmias. After a median follow-up of 24 (15-43) months, 20 (20%) patients had arrhythmic events. Both QRSp and QRS duration were greater in those with arrhythmic events (both P<0.001) and this was consistent for QRSp for both cardiomyopathy types. In a multivariable Cox regression model that included age, left ventricular ejection fraction, QRS duration, and QRSp, only QRSp was an independent predictor of arrhythmic events (hazard ratio, 2.1; P<0.001). Receiver operating characteristic analysis revealed that a QRSp ≥2.25 identified arrhythmic events with greater sensitivity (100% versus 70%, P<0.05) and negative predictive value (100% versus 89%, P<0.05) than QRS duration ≥120 ms. CONCLUSIONS: QRSp measured from high-resolution digital 12-lead ECGs independently predicts ventricular tachyarrhythmias in ICD-eligible cardiomyopathy patients. This novel QRS morphology index has the potential to improve sudden death risk stratification and patient selection for prophylactic ICD therapy.


Assuntos
Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia Ambulatorial , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade
18.
J Cardiovasc Electrophysiol ; 28(9): 1037-1047, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639728

RESUMO

AIMS: Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation. METHODS: Eighty-nine consecutive drug-refractory AF patients (49% paroxysmal) underwent AI-guided ablation (AI-group). AI targets were 550 for anterior/roof and 400 for posterior/inferior left atrial segments. Procedural and clinical outcomes of these patients were compared to 89 propensity-matched controls who underwent CF-guided ablation (CF-group). All 178 procedures were otherwise similar, and both groups were followed-up for 12 months. The last 25 patients from each group underwent analysis of all VisiTags™ for ablation duration, CF, Force-Time Integral, and impedance drop. RESULTS: First-pass pulmonary vein isolation (PVI) was more frequent in AI-group than in CF-group (173 [97%] vs. 149 [84%] circles, P < 0.001), and acute PV reconnection was lower (11 [6%] vs. 24 [13%] circles, P = 0.02). Mean PVI ablation time was similar (AI-group: 42 ± 9 vs. CF-group: 45 ± 14 minutes, P = 0.14). Median impedance drop for AI-group was significantly higher than in CF-group (13.7 [9-19] Ω vs. 8.8 [5.2-13] Ω, P < 0.001). Two major complications occurred in CF-group and none in AI-group. Atrial tachyarrhythmia recurrence was significantly lower in AI-group (15 of 89 [17%]) than in CF-group (33 of 89 [37%], P = 0.002). CONCLUSION: AI-guided ablation is associated with significant improvements in the incidence of acute PV reconnection and atrial tachyarrhythmia recurrence rate compared to CF-guided ablation, potentially due to creation of better quality lesions as suggested by greater impedance drop.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Curva ROC , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 3(6): 602-611, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-29759434

RESUMO

OBJECTIVES: The goal of this study was to determine whether a strategy of early re-isolation of pulmonary vein (PV) reconnection in all patients, regardless of symptoms, would reduce the recurrence of atrial fibrillation (AF) and improve quality of life. BACKGROUND: Lasting pulmonary vein isolation (PVI) remains elusive. PV reconnection is strongly linked to the recurrence of arrhythmia. METHODS: A total of 80 patients with paroxysmal AF were randomized 1:1 after contact force-guided PVI to receive either standard care or undergo a repeat electrophysiology study after 2 months regardless of symptoms (repeat study). At the initial procedure, PVI was demonstrated by entrance/exit block and adenosine administration after a minimum 20-min wait. At the repeat study, all sites of PV reconnection were re-ablated. Patients recorded electrocardiograms daily and whenever symptomatic for 12 months using a handheld monitor. Recurrence was defined as ≥30 s of atrial tachyarrhythmia (AT) after a 3-month blanking period. The Atrial Fibrillation Effect on Quality-of-Life Questionnaire was completed at baseline and at 6 and 12 months. RESULTS: All 40 patients randomized to repeat study attended for this after 62 ± 6 days, of whom 25 (62.5%) had reconnection of 41 (26%) PVs. There were no complications related to these procedures. Subjects recorded a total of 32,203 electrocardiograms (380 [335 to 447] per patient) during 12.6 (12.2 to 13.2) months of follow-up. AT recurrence was significantly lower for the repeat study group (17.5% vs. 42.5%; p = 0.03), as was AT burden (p = 0.03). Scores on the Atrial Fibrillation Effect on Quality-of-Life Questionnaire were higher in the repeat study group at 6 months (p < 0.001) and 12 months (p = 0.02). CONCLUSIONS: A strategy of routine repeat assessment with re-isolation of PV reconnection improved freedom from AT recurrence, AT burden, and quality of life compared with current standard care. (The Effect of Early Repeat Atrial Fibrillation [AF] on AF Recurrence [PRESSURE]; NCT01942408).


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Reoperação , Resultado do Tratamento
20.
Europace ; 19(5): 775-783, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27247002

RESUMO

AIMS: Force-Time Integral (FTI) is commonly used as a marker of ablation lesion quality during pulmonary vein isolation (PVI), but does not incorporate power. Ablation Index (AI) is a novel lesion quality marker that utilizes contact force, time, and power in a weighted formula. Furthermore, only a single FTI target value has been suggested despite regional variation in left atrial wall thickness. We aimed to study AI's and FTI's relationships with PV reconnection at repeat electrophysiology study, and regional threshold values that predicted no reconnection. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients underwent contact force-guided PVI, and the minimum and mean AI and FTI values for each segment were identified according to a 12-segment model. All patients underwent repeat electrophysiology study at 2 months, regardless of symptoms, to identify sites of PV reconnection. Late PV reconnection was seen in 53 (11%) segments in 25 (62%) patients. Reconnected segments had significantly lower minimum AI [308 (252-336) vs. 373 (323-423), P < 0.0001] and FTI [137 (92-182) vs. 228 (157-334), P < 0.0001] compared with non-reconnected segments. Minimum AI and FTI were both independently predictive, but AI had a smaller P value. Higher minimum AI and FTI values were required to avoid reconnection in anterior/roof segments than for posterior/inferior segments (P < 0.0001). No reconnection was seen where the minimum AI value was ≥370 for posterior/inferior segments and ≥480 for anterior/roof segments. CONCLUSION: The minimum AI value in a PVI segment is independently predictive of reconnection of that segment at repeat electrophysiology study. Higher AI and FTI values are required for anterior/roof segments than for posterior/inferior segments to prevent reconnection.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Diagnóstico por Computador/métodos , Sistema de Condução Cardíaco/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento