Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vascular ; : 17085381241256191, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38785381

RESUMO

BACKGROUND: Majority of EVAR procedures are performed with percutaneous arterial access, unless there is severe steno-occlusive disease in the common femoral arteries (CFA). We present our experience of using MANTA closure device with a retrospective evaluation of its safety and efficacy, in the elective setting, and in the emergent setting for ruptured aortic aneurysm. DESIGN AND METHODS: Between Feb 2021 and May 2023 a total of 75 EVAR procedures were closed with a Manta device. Data was collected prospectively and analysed retrospectively. In 75 patients, 128 CFAs were closed with a Manta closure device including 4 emergent ruptured aneurysms. RESULTS: 67 male and 8 female patients with a median age of 77 years had percutaneous EVAR using Manta as a closure device. 128 CFAs were closed with Manta closure device. 3% (4/128) had deployment failures, with three requiring surgical cut down and closure. In one patient, a second Manta device deployment achieved satisfactory haemostasis. Three deployments were complicated by pseudoaneurysms of the CFA, all requiring no further interventions/treatment. No death related to severe haemorrhage from device failure. The pre- and post-procedure CFA puncture site AP diameter was recorded in a total of 106 cases with appropriate follow-up. 66% of these (70/106) had no reduction in CFA diameter post Manta closure. 34% (36/106) had some reduction of vessel AP size CFA post EVAR. No adverse features or further treatment was required due to reduction of vessel diameter in these cases (ongoing yearly surveillance). CONCLUSIONS: Manta closure device is safe and easy to deploy with an overall success rate of 97%. There is a short learning curve. Ultrasound assessment and precise puncture at the healthy section of femoral artery are the key to achieve successful haemostasis with Manta closure device. Our findings suggest there is an association of non-clinically significant mild reduction in CFA vessel AP diameter post Manta closure device, which does not require further intervention.

2.
Clin Res Cardiol ; 105(6): 544-52, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26802018

RESUMO

BACKGROUND: Renal denervation (RDN) may lower blood pressure (BP); however, it is unclear whether medication changes may be confounding results. Furthermore, limited data exist on pattern of ambulatory blood pressure (ABP) response-particularly in those prescribed aldosterone antagonists at the time of RDN. METHODS: We examined all patients treated with RDN for treatment-resistant hypertension in 18 UK centres. RESULTS: Results from 253 patients treated with five technologies are shown. Pre-procedural mean office BP (OBP) was 185/102 mmHg (SD 26/19; n = 253) and mean daytime ABP was 170/98 mmHg (SD 22/16; n = 186). Median number of antihypertensive drugs was 5.0: 96 % ACEi/ARB; 86 % thiazide/loop diuretic and 55 % aldosterone antagonist. OBP, available in 90 % at 11 months follow-up, was 163/93 mmHg (reduction of 22/9 mmHg). ABP, available in 70 % at 8.5 months follow-up, was 158/91 mmHg (fall of 12/7 mmHg). Mean drug changes post RDN were: 0.36 drugs added, 0.91 withdrawn. Dose changes appeared neutral. Quartile analysis by starting ABP showed mean reductions in systolic ABP after RDN of: 0.4; 6.5; 14.5 and 22.1 mmHg, respectively (p < 0.001 for trend). Use of aldosterone antagonist did not predict response (p > 0.2). CONCLUSION: In 253 patients treated with RDN, office BP fell by 22/9 mmHg. Ambulatory BP fell by 12/7 mmHg, though little response was seen in the lowermost quartile of starting blood pressure. Fall in BP was not explained by medication changes and aldosterone antagonist use did not affect response.


Assuntos
Pressão Sanguínea , Hipertensão/cirurgia , Rim/irrigação sanguínea , Artéria Renal/inervação , Simpatectomia/métodos , Sistema Nervoso Simpático/cirurgia , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Resistência a Medicamentos , Quimioterapia Combinada , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Antagonistas de Receptores de Mineralocorticoides , Visita a Consultório Médico , Sistema de Registros , Estudos Retrospectivos , Simpatectomia/efeitos adversos , Sistema Nervoso Simpático/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Reino Unido
3.
Cardiovasc Intervent Radiol ; 34(5): 958-63, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21360240

RESUMO

PURPOSE: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. MATERIALS AND METHODS: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa(®), Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. RESULTS: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. CONCLUSIONS: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies [1].


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Bioprótese , Prótese Vascular , Diálise Renal , Ureter , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Animais , Prótese Vascular/efeitos adversos , Bovinos , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/cirurgia , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...