Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Pollut Res Int ; 26(6): 5410-5421, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30607837

RESUMO

The presence of chemicals in laboratories and research centers exposes the staff working at such indoor environment to health risks. In this piece of research, a study was performed on the indoor environment of the Center for Environmental Engineering Research at Sahand University of Technology (Tabriz, Iran). For this purpose, the parameters affecting the dispersion of volatile organic compounds (VOCs), including ventilation rate, room temperature, pollution emission time, venting location, air flow regime within the indoor environment, and the number of vents, were simulated via CFD modeling. The CFD modeling was performed three-dimensionally in unsteady state. In case of turbulent flow within the indoor environment, k-ε turbulence model was used to obtain air velocity profile. Experimental data was used to validate the model. Results of the present research showed that when the venting location is on the ceiling, pollution concentration of 25 ppm can be achieved at some low temperature under a particular set of conditions. However, when the venting location was on the walls close to the pollution source, concentrations as low as 5 ppm and lower were observed within the laboratory indoor environment.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Modelos Teóricos , Ventilação/métodos , Compostos Orgânicos Voláteis/análise , Poluentes Atmosféricos/análise , Poluição do Ar , Benzeno/análise , Irã (Geográfico) , Laboratórios , Temperatura
2.
Environ Sci Pollut Res Int ; 25(18): 17890-17900, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29679276

RESUMO

One of the important agents menacing buildings' employees and residents' health is the emission of volatile organic compounds (VOCs) into the indoor environment. The present research studied the VOC emission to evaluate indoor air quality (IAQ) through studying in-laboratory processes and tasks. On account of that, three different pollutants (acetone, benzene, and toluene) were chosen as candidate VOCs, and Environmental Engineering Research Center at Sahand University of Technology was selected as a sample laboratory for each VOC. Using CFD model, concentrations of pollutants under unsteady state in a three-dimensional geometry at various temperatures were provided. To validate the considered model, the modeling results were compared to experimental data. Health risk was evaluated through the building using the OEL-C, OEL-STEL, and OEL-TWA parameters for the three pollutants. According to the mentioned parameters and the modeling results, 1 h following the emission, in order to reduce the health risk associated with short-term exposure to the emission, the staff should observe a minimum distance of 3, 2, and 1.8 m to the sources of acetone, benzene, and toluene, respectively. This is while, since average concentration of emission within the laboratory in an 8-h period is several times as large as OEL-TWA, then the laboratory staffs are strictly recommended not to work in the laboratory for long hours. Furthermore, using the results of this research, the staff can detect safe locations within the laboratory without any need to use emission monitoring equipment.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Benzeno/análise , Tolueno/análise , Compostos Orgânicos Voláteis/análise , Benzeno/química , Laboratórios , Medição de Risco , Tolueno/química , Compostos Orgânicos Voláteis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...