Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Sci Eng C Mater Biol Appl ; 129: 112410, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34579919

RESUMO

The development of new materials with antibacterial properties and the scope to decrease or eliminate the excessive antibiotic use is an urgent priority due to the growing antibiotic resistance-related mortalities. New bone substitute materials with intrinsic antibacterial characteristics are highly requested for various clinical applications. In this study, the choice of copper ions as substitutes for calcium in tricalcium phosphate (TCP) has been justified by their pronounced broad-spectrum antibacterial properties. Copper-substituted TCP (Cu-TCP) ceramics with the copper content of 1.4 and 0.1 wt% were synthesized by mechano-chemical activation. X-ray diffraction (XRD) analyses established that both pure and copper-containing compounds adopted the structure of whitlockite (ß-TCP). XRD and electron paramagnetic resonance (EPR) spectroscopy revealed the partial isovalent substitution of calcium ions with copper ions in the ß-TCP lattice. With the use of infrared and EPR spectroscopies, it was detected that carbonate ions got incorporated into the ß-TCP structure during the synthesis procedure. By releasing the tension in the M(5)O6 octahedron consequential to the lower CaO bond length than the corresponding sum of ionic radii, the substitution of calcium with smaller copper ions stabilizes the structure of ß-TCP. As concluded form the thermal analyses, the introduction of Cu prevented the polymorphic transformation of ß- to α-TCP. At the same time, the introduction of Cu to the ß-TCP structure enhanced the crystal growth and porosity of the ceramics, which had a positive effect on the cytocompatibility of the material. The MTT colorimetric assay showed that the metabolic activity of the mouse fibroblast NCTC L929 cell line during 24 h of incubation with 3-day extracts from Cu-TCP (1.4 wt%) and ß-TCP pellets in the cell culture medium was similar to the negative control, indicating the absence of any inhibitory effects on cells. The seeding and the growth of human dental pulp stem cells on the surface of Cu-TCP (1.4 wt%) and ß-TCP ceramics also showed the absence of any signs of cytotoxicity. Finally, microbiological assays demonstrated the antibacterial activity of Cu-TCP ceramics against Escherichia coli and Salmonella enteritidis, whereas ß-TCP did not exhibit such an activity. Overall, the addition of Cu ions to ß-TCP improves its antibacterial properties without diminishing the biocompatibility of the material, thus making it more attractive than pure ß-TCP for clinical applications such as synthetic bone grafts and orthopaedic implant coatings.


Assuntos
Substitutos Ósseos , Cobre , Animais , Antibacterianos/farmacologia , Substitutos Ósseos/farmacologia , Fosfatos de Cálcio , Cerâmica/farmacologia , Camundongos , Difração de Raios X
2.
J Mater Sci Mater Med ; 32(9): 99, 2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34406523

RESUMO

For bone replacement materials, osteoconductive, osteoinductive, and osteogenic properties are desired. The bacterial resistance and the need for new antibacterial strategies stand among the most challenging tasks of the modern medicine. In this work, brushite cements based on powders of Zinc (Zn) (1.4 wt%) substituted tricalcium phosphate (ß-TCP) and non-substituted ß-TCP were prepared and investigated. Their initial and final phase composition, time of setting, morphology, pH evolution, and compressive strength are reported. After soaking for 60 days in physiological solution, the cements transformed into a mixture of brushite and hydroxyapatite. Antibacterial activity of the cements against Enterococcus faecium, Escherichia coli, and Pseudomonas aeruginosa bacteria strains was attested. The absence of cytotoxicity of cements was proved for murine fibroblast NCTC L929 cells. Moreover, the cell viability on the ß-TCP cement containing Zn2+ ions was 10% higher compared to the ß-TCP cement without zinc. The developed cements are perspective for applications in orthopedics and traumatology.


Assuntos
Antibacterianos/farmacologia , Cimentos Ósseos , Substitutos Ósseos , Fosfatos de Cálcio/química , Zinco/química , Animais , Sobrevivência Celular , Força Compressiva , Durapatita , Espectroscopia de Ressonância de Spin Eletrônica , Enterococcus faecium , Escherichia coli , Concentração de Íons de Hidrogênio , Íons , Teste de Materiais , Camundongos , Testes de Sensibilidade Microbiana , Ortopedia , Pós , Pseudomonas aeruginosa , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
3.
Materials (Basel) ; 13(19)2020 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-33022953

RESUMO

Bioactive manganese (Mn)-doped ceramic coatings for intraosseous titanium (Ti) implants are developed. Arc plasma deposition procedure is used for coatings preparation. X-ray Diffraction, Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy, and Electron Paramagnetic Resonance (EPR) methods are applied for coatings characterization. The coatings are homogeneous, composed of the main phase α-tricalcium phosphate (α-TCP) (about 67%) and the minor phase hydroxyapatite (about 33%), and the Mn content is 2.3 wt%. EPR spectroscopy demonstrates that the Mn ions are incorporated in the TCP structure and are present in the coating in Mn2+ and Mn3+ oxidation states, being aggregated in clusters. The wetting contact angle of the deposited coatings is suitable for cells' adhesion and proliferation. In vitro soaking in physiological solution for 90 days leads to a drastic change in phase composition; the transformation into calcium carbonate and octacalcium phosphate takes place, and no more Mn is present. The absence of antibacterial activity against Escherichia coli, Enterococcus faecalis, and Pseudomonas aeruginosa bacteria strains is observed. A study of the metabolic activity of mouse fibroblasts of the NCTC L929 cell line on the coatings using the MTT (dye compound 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) test demonstrates that there is no toxic effect on the cell culture. Moreover, the coating material supports the adhesion and proliferation of the cells. A good adhesion, spreading, and proliferative activity of the human tooth postnatal dental pulp stem cells (DPSC) is demonstrated. The developed coatings are promising for implant application in orthopedics and dentistry.