Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Infant Behav Dev ; 76: 101975, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38986217

RESUMO

Previous work has shown that caregiver attention shapes visual cognition in infants through dyadic interactions. Is this association measurable when visual cognition is objectively measured in caregivers and infants using comparable experimental paradigms? In the current study, we presented infants (N = 86) and caregivers (N = 78) with age-specific variants of the same preferential looking visual cognition task to investigate whether caregiver visual cognition was associated with their infants' visual cognition. In each trial of the task, two side-by-side flashing displays of coloured shapes were presented. On the 'unchanging' side, the colours of the shapes remained the same. On the 'changing' side, the colour of one shape changed after each flash. Load was varied by changing the number of shapes across trials (low, medium, and high loads). We extracted looking dynamics using video recordings and brain function using functional near-infrared spectroscopy as both infants and caregivers engaged with the task. Change preference (CP) score, which represented the amount of time spent looking at the changing side divided by the total looking duration, showed a load-dependent modulation for both infants and caregivers. Both groups showed the highest CP scores at the low load. Further, higher caregiver CP scores was associated with higher infant CP scores at the low load. Both infants and caregivers engaged canonical regions of the fronto-parietal network involved in visual cognition. Critically, higher caregiver CP scores were associated with greater activation in the left superior parietal lobule in younger infants, a region involved in allocating visuo-spatial attention and working memory maintenance. Further, there was spatial overlap between performance-dependent regions in the right parietal cortex in caregivers and younger infants. Our findings provide first evidence of a heritability-related visual neurocognitive association between caregivers and their children in the first year of life.

2.
Infant Behav Dev ; 74: 101921, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211463

RESUMO

Visual working memory (VWM) emerges in the first year of life and has far-reaching implications for academic and later life outcomes. Given that caregivers play a significant role in shaping cognitive function in children, it is important to understand how they might impact VWM development as early as infancy. The current study investigated whether caregivers' efficiency of regulating inhibitory control was associated with VWM function in their infants. Eighty-eight caregivers were presented with a Go-NoGo task to assess inhibitory control. An efficiency score was calculated using their behavioural responses. Eighty-six 6-to-10-month-old infants were presented with a preferential looking task to assess VWM function. VWM load was manipulated across one (low load), two (medium load) and three (high load) items. Functional near-infrared spectroscopy was used to record brain activation from caregivers and their infants. We found no direct association between caregiver efficiency and infant VWM behaviour. However, we found an indirect association - caregiver efficiency was linked to infant VWM through left-lateralized fronto-parietal engagement. Specifically, infants with low efficiency caregivers showed decreasing left-lateralized parietal engagement with increasing VWM performance at the medium and high loads compared to infants with high efficiency caregivers, who did not show any load- or performance-dependent modulation. Our findings contribute to a growing body of literature examining the role that caregivers play in early neurocognitive development.


Assuntos
Cuidadores , Memória de Curto Prazo , Criança , Lactente , Humanos , Memória de Curto Prazo/fisiologia , Encéfalo/fisiologia , Cognição , Percepção Visual/fisiologia
3.
J Breath Res ; 18(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38096565

RESUMO

Due to the overall low abundance of volatile compounds in exhaled breath, it is necessary to preconcentrate the sample prior to traditional thermal desorption (TD) gas chromatography mass spectrometry analysis. While certain aspects of TD tubes, such as volatile storage, have been evaluated, many aspects remain uncharacterized. Two common TD tubes, Tenax TA and Biomonitoring 5TD tubes, were evaluated for background content and flow rate variability. The data illustrate that the Biomonitoring 5TD tubes have the highest number (23) and abundance of background contamination greater than 3x the mean noise when compared to Tenax TA (13) and empty tubes (9). Tentative identifications of the compounds in the background contamination experiment show that greater than 59% (16/27) of the compounds identified have been reported in the breath literature. The data illustrate the TD tube background abundance could account for more than 70% of the chromatographic signal from exhaled breath for these select compounds. Flow rate measurements of 200 Tenax TA and 200 Biomonitoring 5TD tubes show a large range in measured flow rates among the TD tubes (Tenax: 252.9-284.0 ml min-1, 5TD: 220.6-255.1 ml min-1). Finally, TD tubes of each type, Tenax TA and Biomonitoring 5TD, previously established to have high, medium, and low flow rates, show insignificant differences (p> 0.05) among the tubes of different flow rates, using both gas standards and an exhaled breath from a peppermint experiment. Collectively, these results establish overall background compounds attributed to each TD tube type tested. Additionally, while measured flow rate variability is present and plausibly impacts exhaled breath results, the data demonstrate no statistically significant difference was observed between tubes showing high, medium, and low flow rates from two separate sample types.


Assuntos
Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Testes Respiratórios/métodos , Expiração , Cromatografia Gasosa-Espectrometria de Massas/métodos , Padrões de Referência
4.
Am J Obstet Gynecol ; 229(4): B2-B6, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37453651

RESUMO

The recent Society for Maternal-Fetal Medicine Consult Series #65 provides a comprehensive review of transabdominal cerclage. The current article condenses the Consult recommendations regarding patient selection, counseling, and management into 2 simple one-page checklists, one for the primary obstetrical provider and the other for the maternal-fetal medicine consultant or cerclage provider. Moreover, we provide sample templates for medical record notes to document preprocedure counseling and informed consent.

5.
J Breath Res ; 17(3)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37352843

RESUMO

Exhaled breath research has been hindered by a lack of standardization in collection and analysis methodologies. Recently, the Respiration Collector forIn VitroAnalysis (ReCIVA) sampling device has illustrated the potential to provide a consistent and convenient method for exhaled breath collection onto adsorbent media. However, the significant costs, compared to exhaled breath bags, associated with the standardized collector is believed to be the reason for limited widespread use by researchers in the exhaled breath field. For example, in addition to the sampling hardware, a single-use disposable silicon mask affixed with a filter is required for each exhaled breath collection. To reduce the financial burden, streamline device upkeep, reduce waste material, and ease the logistical burden associated with the single use masks, it is hypothesized that the consumable masks and filters could be sterilized by autoclaving for reuse. The masks were contaminated, autoclaved, and then tested for any surviving pathogens with spore strip standards and by measuring the optical density of cultures. The compound background collected when using the ReCIVA with new masks was compared to that collected with repeatedly autoclaved masks via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The capacity to block particulate matter of new filters was tested against that of autoclaved filters by introducing an aerosol and comparing pre-filter and post-filter particle counts. Finally, breath samplings were conducted with new masks and autoclaved masks to test for changes in measurements by TD-GC-MS of exogenous and endogenous compounds. The data illustrate the autoclave cycle sterilizes masks spiked with saliva to background levels (p= 0.2527). The results indicate that background levels of siloxane compounds are increased as masks are repetitively autoclaved. The data show that mask filters have significant breakthrough of 1µm particles after five repetitive autoclaving cycles compared to new filters (p= 0.0219). Finally, exhaled breath results utilizing a peppermint ingestion protocol indicate two compounds associated with peppermint, menthone and 1-Methyl-4-(1-methylethyl)-cyclohexanol, and an endogenous exhaled breath compound, isoprene, show no significant difference if sampled with a new mask or a mask autoclaved five times (p> 0.1063). Collectively, the data indicate that ReCIVA masks and filters can be sterilized via autoclave and reused. The results suggest ReCIVA mask and filter reuse should be limited to three times to limit potentially problematic background contaminants and filter dysfunction.


Assuntos
Testes Respiratórios , Esterilização , Humanos , Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas , Expiração , Padrões de Referência
6.
Dev Cogn Neurosci ; 60: 101205, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36724671

RESUMO

Neurocognition and academic abilities during the period of 4 and 7 years of age are impacted by both the transition from kindergarten to primary school and age-related developmental processes. Here, we used a school cut-off design to tease apart the impact of formal schooling from age, on working memory (WM) function, vocabulary, and numeracy scores. We compared two groups of children with similar age, across two years: first-graders (FG), who were enrolled into primary school the year that they became eligible and kindergarteners (KG), who were deferred school entry until the following year. All children completed a change detection task while brain activation was recorded using portable functional near-infrared spectroscopy, a vocabulary assessment, and a numeracy screener. Our results revealed that FG children showed greater improvement in WM performance and greater engagement of a left-lateralized fronto-parietal network compared to KG children. Further, they also showed higher gains in vocabulary and non-symbolic numeracy scores. This improvement in vocabulary and non-symbolic numeracy scores following a year in primary school was predicted by WM function. Our findings contribute to a growing body of literature examining neurocognitive and academic benefits conferred to children following exposure to formal schooling.


Assuntos
Memória de Curto Prazo , Instituições Acadêmicas , Criança , Humanos , Pré-Escolar , Memória de Curto Prazo/fisiologia , Escolaridade , Cognição , Encéfalo
7.
J Breath Res ; 17(2)2023 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-36596256

RESUMO

Isoprene is one of the most abundant and most frequently evaluated volatile organic compounds in exhaled breath. Recently, several individuals with background levels of exhaled isoprene have been identified. Here, case study data are provided for an individual, identified from a previous study, with this low prevalence phenotype. It is hypothesized that the individual will illustrate low levels of exhaled isoprene at rest and during exercise. At rest, the subject (7.1 ppb) shows background (µ= 14.2 ± 7.0 ppb) levels of exhaled isoprene while the control group illustrates significantly higher quantities (µ= 266.2 ± 72.3 ppb) via proton transfer reaction mass spectrometry (PTR-MS). The result, background levels of isoprene at rest, is verified by thermal desorption gas chromatography mass spectrometry (TD-GC-MS) collections with the individual showing -3.6 ppb exhaled isoprene while the room background containedµ= -4.1 ± 0.1 ppb isoprene. As isoprene has been shown previously to increase at the initiation of exercise, exercise bike experiments were performed with the individual identified with low isoprene, yielding low and invariant levels of exhaled isoprene (µ= 6.6 ± 0.1 ppb) during the exercise while control subjects illustrated an approximate 2.5-fold increase (preµ= 286.3 ± 43.8 ppb, exerciseµ= 573.0 ± 147.8 ppb) in exhaled isoprene upon exercise start. Additionally, exhaled breath bag data showed a significant decrease in isoprene (delta post/pre, p = 0.0078) of the control group following the exercise regimen. Finally, TD-GC-MS results for exhaled isoprene from the individual's family (mother, father, sister and maternal grandmother) illustrated that the mother and father exhibited isoprene values (28.5 ppb, 77.2 ppb) below control samples 95% confidence interval (µ= 166.8 ± 43.3 ppb) while the individual's sister (182.0 ppb) was within the control range. These data provide evidence for a large dynamic range in exhaled isoprene in this family. Collectively, these results provide additional data surrounding the existence of a small population of individuals with background levels of exhaled isoprene.


Assuntos
Testes Respiratórios , Butadienos , Testes Respiratórios/métodos , Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Butadienos/análise , Hemiterpenos/análise , Expiração
8.
Am J Obstet Gynecol ; 228(3): B8-B17, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36481188

RESUMO

The frequency of telemedicine encounters has increased dramatically in recent years. This review summarizes the literature regarding the safety and quality of telemedicine for pregnancy-related services, including prenatal care, postpartum care, diabetes mellitus management, medication abortion, lactation support, hypertension management, genetic counseling, ultrasound examination, contraception, and mental health services. For many of these, telemedicine has several potential or proven benefits, including expanded patient access, improved patient satisfaction, decreased disparities in care delivery, and health outcomes at least comparable to those of traditional in-person encounters. Considering these benefits, it is suggested that payers should reimburse providers at least as much for telemedicine as for in-person services. Areas for future research are considered.


Assuntos
Obstetrícia , Telemedicina , Gravidez , Feminino , Humanos , Perinatologia , Anticoncepção , Cuidado Pré-Natal
9.
Am J Obstet Gynecol ; 227(2): B2-B10, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35487325

RESUMO

The processes of diagnosis and management involve clinical decision-making. However, decision-making is often affected by cognitive biases that can lead to medical errors. This statement presents a framework of clinical thinking and decision-making and shows how these processes can be bias-prone. We review examples of cognitive bias in obstetrics and introduce debiasing tools and strategies. When an adverse event or near miss is reviewed, the concept of a cognitive autopsy-a root cause analysis of medical decision-making and the potential influence of cognitive biases-is promoted as part of the review process. Finally, areas for future research on cognitive bias in obstetrics are suggested.


Assuntos
Cognição , Erros Médicos , Obstetrícia , Viés , Humanos , Perinatologia , Sociedades Médicas , Estados Unidos
10.
BMJ Qual Saf ; 31(9): 670-678, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35428682

RESUMO

The objective of this study was to evaluate the impact of quality improvement (QI) and patient safety initiatives and data disaggregation on racial disparities in severe maternal morbidity from hemorrhage (SMM-H).Our hospital began monitoring and reporting on SMM-overall and SMM-H rates in 2018 using administrative data. In March 2019, we began stratifying data by race and ethnicity and noted a disparity in rates, with non-Hispanic Black women having the highest SMM rates. The data was presented as run charts at monthly department meetings. During this time, our hospital implemented several QI and patient safety initiatives around obstetric hemorrhage and used the stratified data to inform guideline development to reduce racial disparity. The initiatives included implementation of a hemorrhage patient safety bundle and in-depth case reviews of adverse patient outcomes with a health equity focus. We then retrospectively analyzed our data. Our outcome of interest was SMM-H prior to data stratification (pre-intervention: June 2018-February 2019) as compared to after data stratification (post-intervention: March 2019-June 2020).During our study time period, there were 13,659 deliveries: 37% Hispanic, 35% White, 20% Black, 7% Asian and 1% Other. Pre-intervention, there was a statistically significant difference between Black and White women for SMM-H rates (p<0.001). This disparity was no longer significant post-intervention (p=0.138). The rate of SMM-H in Black women decreased from 45.5% to 31.6% (p=0.011).Our findings suggest that QI and patient safety efforts that incorporate race and ethnicity data stratification to identify disparities and use the information to target interventions have the potential to reduce disparities in SMM.


Assuntos
Negro ou Afro-Americano , População Branca , Feminino , Disparidades em Assistência à Saúde , Hemorragia , Humanos , Gravidez , Melhoria de Qualidade , Estudos Retrospectivos
11.
Am J Obstet Gynecol ; 227(2): B44-B59, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35378098

RESUMO

The Centers for Disease Control and Prevention define social determinants of health as "the conditions in the places where people live, learn, work, and play" that can affect health outcomes. Systemic racism is a root cause of the power and wealth imbalances that affect social determinants of health, creating disproportionate rates of comorbidities and adverse outcomes in the communities of racial and ethnic minority groups. Focusing primarily on disparities between Black and White individuals born in the United States, this document reviews the effects of social determinants of health and systemic racism on reproductive health outcomes and recommends multilevel approaches to mitigate disparities in obstetrical outcomes.


Assuntos
Etnicidade , Grupos Minoritários , Feminino , Disparidades em Assistência à Saúde , Humanos , Perinatologia , Determinantes Sociais da Saúde , Racismo Sistêmico , Estados Unidos
12.
Am J Obstet Gynecol ; 227(1): B2-B3, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35337803

RESUMO

The management of pregnancies resulting from in vitro fertilization includes several recommended interventions at various times by various providers. To minimize the chance of errors of omission, the Society for Maternal-Fetal Medicine presents a patient-oriented checklist summarizing the recommended management of such pregnancies.


Assuntos
Lista de Checagem , Perinatologia , Feminino , Fertilização in vitro , Humanos , Gravidez
13.
J Matern Fetal Neonatal Med ; 35(25): 7924-7928, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34134585

RESUMO

OBJECTIVE: To evaluate access to trial of labor after cesarean (TOLAC) in a large metropolitan city. STUDY DESIGN: In 2012, a public tertiary care hospital in Houston, TX promoted its TOLAC services on social media, resulting in a surge of self-referrals. In 2018, an electronic survey was distributed by email to 200 women who had previously contacted the hospital regarding TOLAC and posted on 2 local social media TOLAC sites. Women were asked to participate if they ever sought TOLAC in the Houston area. Data were analyzed for trends in patient experience seeking TOLAC and comparisons were made based on number of prior cesarean deliveries (CD) and race/ethnicity. RESULTS: The survey was open for responses for 1 month, with 128 completed surveys by the end of the study time period. Of the respondents, most (64%) had 1 prior CD and identified as White (63%). Most (60%) of all women reported contacting ≥3 providers before finding one that offered TOLAC, with no difference reported for women with 1 vs 2 prior CD (p = .2). Over half (52%) reported their experience seeking TOLAC to be difficult with more difficulty noted by those with 2 vs 1 prior CD, (61.8% vs 42.7%,) but not statistically significant (p = .06). White women were more likely to report an easier experience seeking TOLAC compared to Black women (55.6% vs 30%, p = .04).Overall, 37% attempted TOLAC at the reference hospital. Black (50%) and Hispanic (68.2%) women were significantly more likely to have delivered at the reference hospital than White women (24%) (p < .05). CONCLUSION: Our results suggest that women seeking TOLAC have difficulty finding providers who offer the service. This may be especially true for Black and Hispanic women and women with >1 prior CD. Women may utilize social media forums for resources and recommendations and such platforms may represent an underutilized opportunity to identify regional TOLAC services.


Assuntos
Prova de Trabalho de Parto , Nascimento Vaginal Após Cesárea , Gravidez , Feminino , Humanos , Masculino , Cesárea , Hospitais , Avaliação de Resultados da Assistência ao Paciente , Estudos Retrospectivos , Recesariana
14.
Epigenetics Chromatin ; 14(1): 37, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34330317

RESUMO

BACKGROUND: Condensation of chromatin prior to enucleation is an essential component of terminal erythroid maturation, and defects in this process are associated with inefficient erythropoiesis and anemia. However, the mechanisms involved in this phenomenon are not well understood. Here, we describe a potential role for the histone variant H2A.X in erythropoiesis. RESULTS: We find in multiple model systems that this histone is essential for normal maturation, and that the loss of H2A.X in erythroid cells results in dysregulation in expression of erythroid-specific genes as well as a nuclear condensation defect. In addition, we demonstrate that erythroid maturation is characterized by phosphorylation at both S139 and Y142 on the C-terminal tail of H2A.X during late-stage erythropoiesis. Knockout of the kinase BAZ1B/WSTF results in loss of Y142 phosphorylation and a defect in nuclear condensation, but does not replicate extensive transcriptional changes to erythroid-specific genes observed in the absence of H2A.X. CONCLUSIONS: We relate these findings to Caspase-Initiated Chromatin Condensation (CICC) in terminal erythroid maturation, where aspects of the apoptotic pathway are invoked while apoptosis is specifically suppressed.


Assuntos
Cromatina , Eritropoese , Caspases , Histonas/metabolismo , Fosforilação
15.
Front Chem ; 9: 659583, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34026725

RESUMO

Sweat is emerging as a prominent biosource for real-time human performance monitoring applications. Although promising, sources of variability must be identified to truly utilize sweat for biomarker applications. In this proof-of-concept study, a targeted metabolomics method was applied to sweat collected from the forearms of participants in a 12-week exercise program who ingested either low or high nutritional supplementation twice daily. The data establish the use of dried powder mass as a method for metabolomic data normalization from sweat samples. Additionally, the results support the hypothesis that ingestion of regular nutritional supplementation semi-quantitatively impact the sweat metabolome. For example, a receiver operating characteristic (ROC) curve of relative normalized metabolite quantities show an area under the curve of 0.82 suggesting the sweat metabolome can moderately predict if an individual is taking nutritional supplementation. Finally, a significant correlation between physical performance and the sweat metabolome are established. For instance, the data illustrate that by utilizing multiple linear regression modeling approaches, sweat metabolite quantities can predict VO2 max (p = 0.0346), peak lower body Windage (p = 0.0112), and abdominal circumference (p = 0.0425). The results illustrate the need to account for dietary nutrition in biomarker discovery applications involving sweat as a biosource.

16.
Obstet Gynecol ; 137(1): 180-181, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399421

Assuntos
Plexo Braquial , Humanos
17.
Talanta ; 223(Pt 1): 121797, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33303130

RESUMO

As the demand for real-time exercise performance feedback increases, excreted sweat has become a biosource of interest for continuous human performance assessment. For sweat to truly fulfill this requirement, analyte concentrations must be normalized to adequately assess day-to-day differences within and among individuals. In this manuscript, data are presented highlighting the use of accurate localized sweat rate as a means for ion and global metabolomic data normalization. The results illustrate large sweat rate variability among individuals over the course of two distinct exercises protocols. Furthermore, the data show sweat rate is not symmetrical at similar locations among right and left forearms of individuals (p = 0.0007). Sweat ion conductivity analysis suggest overall sweat rate normalization reduces variability collectively among ion values and participants with principal component analysis showing 77.8% of variation in the data set attributable to sweat rate normalization. Global metabolomic analysis of sweat illustrated overall rate normalization increases the variability among test subjects with 72.7% of the variation explained by sweat rate normalization. Finally, overall rate normalized metabolomic features of sweat significantly correlated (ρ ≥ 0.7, ρ ≤ -0.7) with measured performance metrics of the individual, establishing the potential for sweat to be used as a biosource for performance monitoring. Collectively, these data illustrate the importance of accurate localized sweat rate determination, for analyte data normalization, in support for the use of sweat in biomarker discovery efforts to predict human performance.


Assuntos
Metabolômica , Suor , Biomarcadores , Exercício Físico , Humanos , Análise de Componente Principal
18.
J Womens Health (Larchmt) ; 30(2): 265-269, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33227226

RESUMO

The pregnancy-related mortality rate in the US exceeds that of other developed nations and is marked by significant disparities in outcome by race. This article reviews the evidence supporting the implementation of a variety of best practices designed to reduce maternal mortality. Evidence from maternal mortality review committees suggests that delays in diagnosis, delays in initiation of treatment and use of ineffective treatments contribute to preventable cases of maternal death. We review several protocols for maternal warning signs that have been used successfully to facilitate early identification and intervention. Care bundles, a collection of best practices, have been developed and implemented to address several maternal emergencies. We review the evidence that supports reduction in adverse outcomes with consistent implementation of obstetric hemorrhage and severe hypertension bundles in a collaborative, team-based setting. The article concludes with suggestions for the future.


Assuntos
Morte Materna , Mortalidade Materna , Feminino , Hemorragia , Humanos , Gravidez , Medição de Risco
19.
Nat Commun ; 11(1): 4544, 2020 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-32917861

RESUMO

Stratification of enhancers by signal strength in ChIP-seq assays has resulted in the establishment of super-enhancers as a widespread and useful tool for identifying cell type-specific, highly expressed genes and associated pathways. We examine a distinct method of stratification that focuses on peak breadth, termed hyperacetylated chromatin domains (HCDs), which classifies broad regions exhibiting histone modifications associated with gene activation. We find that this analysis serves to identify genes that are both more highly expressed and more closely aligned to cell identity than super-enhancer analysis does using multiple data sets. Moreover, genetic manipulations of selected gene loci suggest that some enhancers located within HCDs work at least in part via a distinct mechanism involving the modulation of histone modifications across domains and that this activity can be imported into a heterologous gene locus. In addition, such genetic dissection reveals that the super-enhancer concept can obscure important functions of constituent elements.


Assuntos
Cromatina/metabolismo , Elementos Facilitadores Genéticos/genética , Loci Gênicos/genética , Ativação Transcricional , Acetilação , Animais , Linhagem Celular Tumoral , Imunoprecipitação da Cromatina , Sequenciamento de Cromatina por Imunoprecipitação , Conjuntos de Dados como Assunto , Embrião de Mamíferos , Eritroblastos , Feminino , Feto , Código das Histonas/genética , Histonas/genética , Histonas/metabolismo , Humanos , Camundongos , Regiões Promotoras Genéticas/genética , RNA-Seq
20.
Obstet Gynecol ; 136(4): 725-730, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32925630

RESUMO

OBJECTIVE: To analyze the origins and consequences of cases of brachial plexus injuries and their relationship to shoulder dystocia. METHODS: We conducted a retrospective cohort study and identified all neonates with brachial plexus injury delivered at our institution between March 2012 and July 2019. A review was performed of the maternal and neonatal records of each neonate to identify obstetric antecedents, including the occurrence of shoulder dystocia and persistence of the injury. Experience of the delivering clinician was also examined. Statistical analysis was performed with the Fisher exact test, χ test for trends, and two-tailed t tests. RESULTS: Thirty-three cases of brachial plexus injury were identified in 41,525 deliveries (0.08%). Fourteen (42%) of these cases were not associated with shoulder dystocia; three (9%) followed cesarean delivery. Brachial plexus injury without shoulder dystocia was related to the absence of maternal diabetes, lower birth weights, and a longer second stage of labor. Persistent brachial plexus injury at the time of discharge was seen with equal frequency among neonates with (17/19, 89%, 95% CI 0.52-100%) and without shoulder dystocia (10/14, 71%, 95% CI 34-100%), P=.36). Whether brachial plexus injury was transient or persistent after shoulder dystocia was unrelated to the years of experience of the delivering clinician. Despite ongoing training and simulation, the already low incidence of brachial plexus injury did not decrease over time at our institution. CONCLUSION: Brachial plexus injury and shoulder dystocia represent two complications of uterine forces driving a fetus through the maternal pelvis in the presence of disproportion between the passage and the shoulder girdle of the passenger. Either or both of these complications may occur, but often are not causally related.


Assuntos
Cesárea , Parto Obstétrico , Paralisia do Plexo Braquial Neonatal , Distocia do Ombro , Adulto , Causalidade , Cesárea/efeitos adversos , Cesárea/estatística & dados numéricos , Parto Obstétrico/efeitos adversos , Parto Obstétrico/estatística & dados numéricos , Registros Eletrônicos de Saúde/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Masculino , Paralisia do Plexo Braquial Neonatal/epidemiologia , Paralisia do Plexo Braquial Neonatal/etiologia , Paralisia do Plexo Braquial Neonatal/fisiopatologia , Gravidez , Resultado da Gravidez/epidemiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Distocia do Ombro/epidemiologia , Distocia do Ombro/etiologia , Distocia do Ombro/fisiopatologia , Texas/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...