Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 205: 111186, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38224647

RESUMO

The determination of activity concentrations of the CTBT-relevant radioxenon relies on a robust calibration method. A procedure is outlined using four radioxenon spikes for beta-gamma detector-systems with 4π geometry. Detection efficiencies of beta-gamma coincidences in the net count calculation method, including the interference matrix between radioxenon and radon, are determined by three measurement channels: beta singles, gamma singles and beta-gamma coincidences, without reference activity values.

2.
J Environ Radioact ; 272: 107357, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38159463

RESUMO

The International Monitoring System (IMS) is a unique global network of sensors, tuned to measure various phenomenology, with the common goal of detecting a nuclear explosion anywhere in the world. One component of this network collects measurements of radioactive particulates and gases (collectively known as radionuclides) present in the atmosphere; through this, compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) can be verified. The radionuclide sub-network consists of 120 sensors across 80 locations, supported by 16 measurement laboratories. All radionuclide stations make use of a form of γ-ray spectroscopy to measure radionuclides from samples; this remains largely unchanged since the network was first established 25 years ago. Advances in sampling and spectroscopy systems can yield improvements to the sensitivity of the network to detect a nuclear explosion. This paper summarises the status of the IMS radionuclide network, the current suite of technology used and reviews new technology that could enhance future iterations, potentially improving the verification power of the IMS.


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Monitoramento de Radiação/métodos , Poluentes Radioativos do Ar/análise , Radioisótopos/análise , Espectrometria gama , Cooperação Internacional , Radioisótopos de Xenônio/análise
3.
Brain Behav ; 13(8): e3105, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37381651

RESUMO

OBJECTIVE: Eating disorders (EDs) are a heterogenous group of disorders characterized by disturbed eating patterns. Links have been made between ED symptoms and control-seeking behaviors, which may cause relief from distress. However, whether direct behavioral measures of control-seeking behavior correlate with ED symptoms has not been directly tested. Additionally, existing paradigms may conflate control-seeking behavior with uncertainty-reducing behavior. METHOD: A general population sample of 183 participants completed part in an online behavioral task, in which participants rolled a die in order to obtain/avoid a set of numbers. Prior to each roll, participants could choose to change arbitrary features of the task (such as the color of their die) or view additional information (such as the current trial number). Selecting these Control Options could cost participants points or not (Cost/No-Cost conditions). Each participant completed all four conditions, each with 15 trials, followed by a series of questionnaires, including the Eating Attitudes Test-26 (EAT-26), the Intolerance of Uncertainty Scale, and the Obsessive-Compulsive Inventory-Revised (OCI-R). RESULTS: A Spearman's rank test indicated no significant correlation between total EAT-26 score and total number of Control Options selected, with only elevated scores on a measure of obsessions and compulsivity (OCI-R) correlating with the total number of Control Options selected (rs  = .155, p = .036). DISCUSSION: In our novel paradigm, we find no relationship between EAT-26 score and control-seeking. However, we do find some evidence that this behavior may be present in other disorders that often coincide with ED diagnosis, which may indicate that transdiagnostic factors such as compulsivity are important to control-seeking.


Assuntos
Comportamento Alimentar , Transtornos da Alimentação e da Ingestão de Alimentos , Humanos , Inquéritos e Questionários , Transtornos da Alimentação e da Ingestão de Alimentos/diagnóstico , Transtornos da Alimentação e da Ingestão de Alimentos/terapia , Incerteza
4.
Sci Rep ; 13(1): 6967, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37117252

RESUMO

The legalisation of hemp has led to wide commercial availability of cannabidiol (CBD)-containing products. Here we show that the CBD-hydroxyquinone (HU-331), a readily formed oxidation product and common impurity in CBD isolates, undergoes a previously unknown photo-isomerisation to produce a highly reactive intermediate in solution. Studies supported by calculations indicate that this intermediate rapidly reacts with oxygen to form a multitude of cannabinoid products. The purple colour observed in light-aged CBD-containing solutions is largely due to the anions of these by-products and is not significantly due to the HU-331 anion. Our findings suggest that these uncharacterized cannabinoid derivatives can be present in CBD-containing e-liquids and solutions that have been stored under ambient light conditions, calling for quality control processes that manage HU-331 contamination.

5.
J Environ Radioact ; 250: 106915, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35653874

RESUMO

A high-resolution ß - Î³ coincidence spectrometry system has been set-up and calibrated at the UK CTBT Radionuclide Laboratory (known as GBL15) at AWE. The system has been configured specifically to measure the signatures of radioxenon isotopes that can be indicative of a nuclear explosion. The high purity germanium (HPGe) and PIPSBox detectors have been placed in an ultra-low-background lead shield to reduce the background count-rate and new software allows the combination of signals from four detectors (two HPGe detectors and two silicon-based detectors) to cover a larger solid angle. Measurements of samples of radioxenon isotopes are used to realise an improved detection efficiency and background acquisitions have demonstrated the achievable detection limits to reach 1.3 mBq for 133Xe and ≤0.3 mBq for the metastable isomers 131mXe and 133mXe. Due to the improved energy resolution in both photon and electron detectors, the detection sensitivity remains high in the presence of interfering signals from other radioxenon isotopes, such as those that may be present due to the significant levels of atmospheric radioxenon in parts of the world. This paper summarises the detector setup, efficiency calibration measurements and determination of the limits of detection. This work demonstrates the benefits of high-resolution coincidence detector systems for re-measurement of samples from the CTBT International Monitoring System (IMS) - improved detectability of metastable isomers 131mXe and 133mXe in the presence of 133Xe, compared to the current laboratory system.

6.
Chem Commun (Camb) ; 58(25): 4099-4102, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35289825

RESUMO

Our recent Communication suggested that ammonia in aqueous solution may preferentially destabilize large cages in methane clathrate hydrates. A Comment favored ammonia incorporation instead, but it did not accurately describe our proposed mechanism and relied primarily on studies conducted in different chemical systems and/or which used other preparation methods.

7.
J Environ Radioact ; 242: 106789, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34872009

RESUMO

The United Kingdom (UK) National Data Centre (NDC) operates a series of custom-developed software tools for the automatic processing, analysis, archiving and interpretation of radionuclide (RN) data from the International Monitoring System (IMS) - the primary instrument for verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The software in-use at the NDC includes an RN Pipeline for the retrieval, analysis, categorisation and archiving of noble gas and particulate radionuclide data. On the identification of a treaty-relevant radionuclide detection or plume of radioxenon, a 'radionuclide detection event' is formed. A series of atmospheric transport and dispersion simulations are activated, and the data is added to the 'RN Event' database where the detection is compared with forward simulations from known or suspected radionuclide emitters. The field of regard for a radionuclide detection event is cross-checked with others to identify possible associated detections, and finally a source reconstruction tool (known as FREAR) is used to determine the source parameters - location, magnitude, emission start time and emission stop time.


Assuntos
Monitoramento de Radiação , Cooperação Internacional , Radioisótopos , Reino Unido
8.
J Environ Radioact ; 238-239: 106733, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34492603

RESUMO

Gaseous fission products have been produced via thermal neutron irradiation of a highly-enriched uranium target and extracted using a custom gas processing system for measurement on a prototype, high-resolution ß - Î³ coincidence detection system. The gas was extracted and measured in two stages in order to measure the prompt and ß--delayed fission products. This paper presents an overview of the system used to produce gaseous fission products, and the results of the advanced coincidence spectrometry techniques used to identify and quantify decays from the radionuclides produced, including the noble gases 85Kr, 85mKr, 88Kr, 133Xe, 135Xe, 133mXe and 135mXe, as well as 133I and 88Rb. The measurements were validated by determination of the nuclear decay half-lives, specifically for the ground state decay of 135Xe, which was found to be 9.15(49) hours and consistent with the literature value. This work demonstrates the UK capability to produce gaseous radionuclides for quality assurance and calibration purposes in Radionuclide Laboratories supporting the Comprehensive Nuclear-Test-Ban Treaty (CTBT).


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Poluentes Radioativos do Ar/análise , Gases Nobres , Radioisótopos , Radioisótopos de Xenônio/análise
9.
J Environ Radioact ; 234: 106629, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33989843

RESUMO

Radioxenon activity concentrations are monitored globally using the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organisation, improving the monitoring community's ability to detect radionuclide signatures from an underground nuclear test (UNT). An IMS-like noble gas system is in operation at AWE (Aldermaston, UK) and can collect and measure radioxenon isotopes in environmental air samples. When operated in this mode, data produced is analysed at the UK National Data Centre (NDC) and significant detection events are flagged for further investigation. This work discusses a number of significant detection events analysed using the operational system deployed at the UK NDC, which includes atmospheric transport simulations and a real-time stack-monitoring data feed from the nearest medical isotope production facility in Belgium. A comparison of the expected radionuclide contributions with measured detections is presented, including a comparison of the isotopic ratios for the radioxenon isotopes of interest (133Xe, 131mXe, 133mXe, 135Xe).


Assuntos
Poluentes Radioativos do Ar , Monitoramento de Radiação , Poluentes Radioativos do Ar/análise , Bélgica , Reino Unido , Radioisótopos de Xenônio/análise
10.
Chem Commun (Camb) ; 56(82): 12391-12394, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-32935703

RESUMO

The incorporation of ammonia inside methane clathrate hydrate is of great interest to the hydrate chemistry community. We investigated the phase behavior of methane clathrate formed from aqueous ammonia solution. Ammonia's presence decreases methane occupancy in the large cages, without definitive Raman spectroscopic evidence for its incorporation inside the structure.

11.
Sci Technol Human Values ; 43(4): 671-693, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30008493

RESUMO

The use of nonhuman animals as models in research and drug testing is a key route through which contemporary scientific knowledge is certified. Given ethical concerns, regulation of animal research promotes the use of less "sentient" animals. This paper draws on a documentary analysis of legal documents and qualitative interviews with Named Veterinary Surgeons and others at a commercial laboratory in the UK. Its key claim is that the concept of animal sentience is entangled with a particular imaginary of how the general public or wider society views animals. We call this imaginary societal sentience. Against a backdrop of increasing ethnographic work on care encounters in the laboratory, this concept helps to stress the wider context within which such encounters take place. We conclude that societal sentience has potential purchase beyond the animal research field, in helping to highlight the affective dimension of public imaginaries and their ethical consequences. Researching and critiquing societal sentience, we argue, may ultimately have more impact on the fate of humans and nonhumans in the laboratory than focusing wholly on ethics as situated practice.

12.
J Environ Radioact ; 192: 667-686, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29525108

RESUMO

After performing a first multi-model exercise in 2015 a comprehensive and technically more demanding atmospheric transport modelling challenge was organized in 2016. Release data were provided by the Australian Nuclear Science and Technology Organization radiopharmaceutical facility in Sydney (Australia) for a one month period. Measured samples for the same time frame were gathered from six International Monitoring System stations in the Southern Hemisphere with distances to the source ranging between 680 (Melbourne) and about 17,000 km (Tristan da Cunha). Participants were prompted to work with unit emissions in pre-defined emission intervals (daily, half-daily, 3-hourly and hourly emission segment lengths) and in order to perform a blind test actual emission values were not provided to them. Despite the quite different settings of the two atmospheric transport modelling challenges there is common evidence that for long-range atmospheric transport using temporally highly resolved emissions and highly space-resolved meteorological input fields has no significant advantage compared to using lower resolved ones. As well an uncertainty of up to 20% in the daily stack emission data turns out to be acceptable for the purpose of a study like this. Model performance at individual stations is quite diverse depending largely on successfully capturing boundary layer processes. No single model-meteorology combination performs best for all stations. Moreover, the stations statistics do not depend on the distance between the source and the individual stations. Finally, it became more evident how future exercises need to be designed. Set-up parameters like the meteorological driver or the output grid resolution should be pre-scribed in order to enhance diversity as well as comparability among model runs.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação , Radioisótopos de Xenônio/análise , Austrália , Cooperação Internacional
13.
Frontline Gastroenterol ; 9(2): 92-97, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29588835

RESUMO

BACKGROUND: In 2012, the National Institute for Health and Care Excellence (NICE) assessed guidance (DG7) on the use of tauroselcholic (75selenium) acid (also known as SeHCAT) for the investigation of diarrhoea due to bile acid malabsorption (BAM) in patients with IBS-D and in patients with Crohn's disease who have not had an ileal resection. NICE concluded that tauroselcholic (75selenium) acid was recommended for use in research only. NICE will be reviewing the decision to update the guidance for tauroselcholic (75selenium) acid, for these populations, in March 2017. AIM: Our aim is to summarise advances in BAM, also known as bile acid diarrhoea (BAD), and encourage clinicians to re-evaluate their understanding of this disorder. APPROACH: We review the prevalence, diagnosis and treatment of BAD/BAM. We describe the new evidence available since the original NICE review in 2012, and discuss the economic issues associated with failure to diagnose or to treat BAD/BAM accurately. EVIDENCE UPDATE: There is new and compelling evidence available since DG7, which shows that tauroselcholic (75selenium) acid scanning is a powerful tool in the diagnosis of BAD/BAM. We summarise published prevalence data (approximately 1% prevalence in the UK, as suggested by clinical practice diagnosis rates), and highlight that the true prevalence of BAD/BAM could be far greater than this. CONCLUSION: We present evidence that challenges current opinion about this disorder, and we commend both clinicians and health technology assessment (HTA) agencies for being open to arguments and new evidence in any future HTAs.

14.
Bull Volcanol ; 79(6): 46, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-32025076

RESUMO

The proximity of the major city of Arequipa to El Misti has focused attention on the hazards posed by the active volcano. Since its last major eruption in the fifteenth century, El Misti has experienced a series of modest phreatic eruptions and fluctuating fumarolic activity. Here, we present the first measurements of the compositions of gas emitted from the lava dome in the summit crater. The gas composition is found to be fairly dry with a H2O/SO2 molar ratio of 32 ± 3, a CO2/SO2 molar ratio of 2.7 ± 0.2, a H2S/SO2 molar ratio of 0.23 ± 0.02 and a H2/SO2 molar ratio of 0.012 ± 0.002. This magmatic gas signature with minimal evidence of hydrothermal or wall rock interaction points to a shallow magma source that is efficiently outgassing through a permeable conduit and lava dome. Field and satellite observations show no evolution of the lava dome over the last decade, indicating sustained outgassing through an established fracture network. This stability could be disrupted if dome permeability were to be reduced by annealing or occlusion of outgassing pathways. Continued monitoring of gas composition and flux at El Misti will be essential to determine the evolution of hazard potential at this dangerous volcano.

15.
J Environ Radioact ; 149: 158-63, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26254208

RESUMO

A method for quantifying gamma coincidence signatures has been developed, and tested in conjunction with a high-efficiency multi-detector system to quickly identify trace amounts of radioactive material. The γ-γ system utilises fully digital electronics and list-mode acquisition to time-stamp each event, allowing coincidence matrices to be easily produced alongside typical 'singles' spectra. To quantify the coincidence signatures a software package has been developed to calculate efficiency and cascade summing corrected branching ratios. This utilises ENSDF records as an input, and can be fully automated, allowing the user to quickly and easily create/update a coincidence library that contains all possible γ and conversion electron cascades, associated cascade emission probabilities, and true-coincidence summing corrected γ cascade detection probabilities. It is also fully searchable by energy, nuclide, coincidence pair, γ multiplicity, cascade probability and half-life of the cascade. The probabilities calculated were tested using measurements performed on the γ-γ system, and found to provide accurate results for the nuclides investigated. Given the flexibility of the method, (it only relies on evaluated nuclear data, and accurate efficiency characterisations), the software can now be utilised for a variety of systems, quickly and easily calculating coincidence signature probabilities.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação/métodos , Radioisótopos/análise , Método de Monte Carlo , Probabilidade , Espectrometria gama
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...