Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Clin Sleep Med ; 18(12): 2703-2712, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35934926

RESUMO

STUDY OBJECTIVES: Evaluate per-patient diagnostic performance of a wireless dual-sensor system (ANNE sleep) compared with reference standard polysomnography (PSG) for the diagnosis of moderate and severe obstructive sleep apnea (OSA) with a minimum prespecified threshold of 80% for both sensitivity and specificity. METHODS: A multicenter clinical trial was conducted to evaluate ANNE sleep vs PSG to diagnose moderate and severe OSA in individuals 22 years or older. For each testing approach, apnea-hypopnea index (AHI) was manually scored and averaged by 3 registered sleep technologists blinded to the other system. Average variations > 15% were adjudicated by a sleep medicine physician. RESULTS: In a total of n = 225 participants (mean age 53 years, range 22-88 years), PSG diagnosed 30% (n = 68) of participants with moderate or severe OSA (AHI ≥ 15 events/h) compared to 29% (n = 65) diagnosed by ANNE sleep (P = .55). The sensitivity and specificity for ANNE sleep were 90% (95% confidence interval: 80-96%) and 98% (95% confidence interval: 94-99%), respectively. Strong correlation was shown in terms of final AHI (r = .93), with an average AHI bias of 0.5 (95% limits of agreement: -12.8 to 11.8). The majority of users noted comfort with using the ANNE sleep in the home setting. No adverse events were noted. CONCLUSIONS: Using PSG as the gold standard, ANNE sleep demonstrated high sensitivity and specificity for the diagnosis of moderate or severe OSA. CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Comparative Study of the ANNE™ One System to Diagnose Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT04643782; Identifier: NCT04643782. CITATION: Davies C, Lee JY, Walter J et al. A single-arm, open-label, multicenter, and comparative study of the ANNE sleep system vs polysomnography to diagnose obstructive sleep apnea. J Clin Sleep Med. 2022;18(12):2703-2712.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Sono , Sensibilidade e Especificidade
2.
Maturitas ; 157: 62-65, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35120674

RESUMO

Phthalates are endocrine-disrupting chemicals that influence endogenous hormones. Few studies have examined the link between phthalates and menopause. A recent secondary analysis revealed that phthalates were associated with self-reported sleep measures in perimenopausal women. However, the associations between phthalate exposure and additional measures of sleep remain unknown. We recruited a population of 27 midlife women (aged 45-54) to study the relationship between phthalate exposure and both subjective and objective measures of sleep. Preliminary results indicate that women with higher phthalate exposure have reduced sleep quality, more frequent sleep disruptions, and more restless sleep compared to women with lower exposure.


Assuntos
Disruptores Endócrinos , Ácidos Ftálicos , Disruptores Endócrinos/toxicidade , Exposição Ambiental , Feminino , Humanos , Menopausa , Ácidos Ftálicos/toxicidade , Sono
3.
Eur J Dent ; 16(4): 749-755, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33412609

RESUMO

OBJECTIVES: The purpose of this pilot study was to determine whether compliance to auto-adjusting positive airway pressure (APAP) improves with the addition of a mandibular advancement device (MAD). Secondary outcome measures included were APAP pressure, subjective daytime sleepiness, apnea-hypopnea index (AHI), and mask leaks. SETTING AND SAMPLE POPULATION: Participants included were diagnosed with moderate-to-severe obstructive sleep apnea (OSA) and became noncompliant to prescribed APAP. Thirteen participants with a mean age of 61.6 years were recruited for this study. MATERIALS AND METHODS: All participants were given a MAD to use with their APAP. Parameters measured included APAP pressure, AHI, mask leak reported via ResMed AirViewTM software, and self-reported daytime sleepiness (Epworth Sleepiness Scale [ESS]). A paired two-sample for mean t-test was performed to determine significance. RESULTS: The mean difference of pre- and postintervention APAP compliance was 23.1%, which was statistically significant (p = 0.015). The mean APAP air pressures were unchanged. The difference between pre- and postintervention mean ESS scores was 1.4 and was statistically significant (p = 0.027). The mean difference between pre- and postintervention AHI values and mask leak showed no significant difference. CONCLUSION: This study showed that combination of APAP-MAD therapy, for patients with moderate-to-severe OSA who were noncompliant to APAP use, significantly increased compliance with APAP therapy, and significantly decreased the daytime sleepiness of participants.

4.
Nat Biomed Eng ; 4(2): 148-158, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31768002

RESUMO

Skin-mounted soft electronics that incorporate high-bandwidth triaxial accelerometers can capture broad classes of physiologically relevant information, including mechano-acoustic signatures of underlying body processes (such as those measured by a stethoscope) and precision kinematics of core-body motions. Here, we describe a wireless device designed to be conformally placed on the suprasternal notch for the continuous measurement of mechano-acoustic signals, from subtle vibrations of the skin at accelerations of around 10-3 m s-2 to large motions of the entire body at about 10 m s-2, and at frequencies up to around 800 Hz. Because the measurements are a complex superposition of signals that arise from locomotion, body orientation, swallowing, respiration, cardiac activity, vocal-fold vibrations and other sources, we exploited frequency-domain analysis and machine learning to obtain-from human subjects during natural daily activities and exercise-real-time recordings of heart rate, respiration rate, energy intensity and other essential vital signs, as well as talking time and cadence, swallow counts and patterns, and other unconventional biomarkers. We also used the device in sleep laboratories and validated the measurements using polysomnography.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Fenômenos Fisiológicos , Tecnologia sem Fio/instrumentação , Clavícula , Desenho de Equipamento , Exercício Físico/fisiologia , Humanos , Processamento de Sinais Assistido por Computador , Fenômenos Fisiológicos da Pele , Sono/fisiologia , Vibração
5.
Sci Transl Med ; 10(435)2018 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-29618561

RESUMO

Thin, soft, skin-like sensors capable of precise, continuous measurements of physiological health have broad potential relevance to clinical health care. Use of sensors distributed over a wide area for full-body, spatiotemporal mapping of physiological processes would be a considerable advance for this field. We introduce materials, device designs, wireless power delivery and communication strategies, and overall system architectures for skin-like, battery-free sensors of temperature and pressure that can be used across the entire body. Combined experimental and theoretical investigations of the sensor operation and the modes for wireless addressing define the key features of these systems. Studies with human subjects in clinical sleep laboratories and in adjustable hospital beds demonstrate functionality of the sensors, with potential implications for monitoring of circadian cycles and mitigating risks for pressure-induced skin ulcers.


Assuntos
Técnicas Biossensoriais/métodos , Tecnologia sem Fio , Desenho de Equipamento , Humanos , Pressão , Pele , Temperatura , Termografia
6.
J Clin Sleep Med ; 12(12): 1669-1680, 2016 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-27655450

RESUMO

STUDY OBJECTIVES: To determine the depth and distribution of sensory discomfort in idiopathic restless legs syndrome/Willis-Ekbom disease (RLS) and RLS concurrent with other leg conditions, specifically peripheral neuropathy, sciatica, leg cramps, and arthritis. METHODS: RLS subjects (n = 122) were divided into 71 idiopathic RLS and 51 RLS-C, or Comorbid, groups. All subjects were examined by an RLS expert, answered standardized RLS questionnaires, and received a body diagram to draw the location and depth of their symptoms. RESULTS: Age was 63.04 ± 12.84 years, with 77 females and 45 males. All patients had lower limb involvement and 43/122 (35.25%) also had upper limb involvement. Of the 122 subjects, 42.62% felt that the RLS discomfort was only deep, 9.84% felt that the discomfort was only superficial, and 47.54% felt both superficial and deep discomfort. There were no defining characteristics in depth or distribution of RLS sensations that differentiated those patients with idiopathic RLS from those patients with RLS associated with other comorbid leg conditions. The sensation of arthritis was felt almost exclusively in the joints and not in the four quadrants of the leg, whereas the exact opposite was true of RLS sensations. CONCLUSIONS: Depth and distribution cannot be used as a discriminative mechanism to separate out idiopathic RLS from RLS comorbid with other leg conditions. Although seen in clinical practice, the total absence of patients with non-painful RLS only in the joints in the current study attests to the rarity of this presentation and raises the possibility of misdiagnosis under these circumstances. We recommend that such patients not be admitted to genetic or epidemiological studies.


Assuntos
Síndrome das Pernas Inquietas/epidemiologia , Síndrome das Pernas Inquietas/fisiopatologia , Inquéritos e Questionários , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome das Pernas Inquietas/diagnóstico , Índice de Gravidade de Doença
7.
Sleep Med Clin ; 11(3): 287-98, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27542875

RESUMO

There is evidence that obstructive sleep apnea (OSA) can negatively impact attention, memory, learning, executive function, and overall intellectual function in adults and children. Imaging techniques, including MRI, MR diffusion tensor imaging, MR spectroscopy, and fMRI, have provided additional insight into the anatomic and functional underpinnings of OSA-related cognitive impairment. Both animal and human studies have looked to elucidate the separate effects of oxygen desaturation and sleep fragmentation on independent aspects of cognition. Data from animal models point to neuro-inflammation and oxidative stress as driving factors of cognitive impairment.


Assuntos
Disfunção Cognitiva/terapia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Disfunção Cognitiva/etiologia , Humanos , Apneia Obstrutiva do Sono/complicações
8.
BMC Res Notes ; 8: 114, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25889945

RESUMO

BACKGROUND: High quality routine health system data is essential for tracking progress towards attainment of the Millennium Development Goals 4 & 5. This study aimed to determine the completeness and accuracy of transfer of routine maternal health service data at health facility, district and regional levels of the Greater Accra Region of Ghana. METHODS: A cross sectional study was conducted using secondary data comprised of routine health information data collected at facility level for the first quarter of 2012. Twelve health facilities were selected using a multistage sampling method. Data relating to antenatal care and delivery were assessed for completeness and accuracy of data transfer. Primary source data from health facility level (registers and record notebooks where health information data are initially entered) , used as the reference data, were counted, collated, and compared with aggregate data on aggregate forms compiled from these sources by health facility staff. The primary source data was also compared with data in the district health information management system (DHIMS-II), a web-based data collation and reporting system. Percentage completeness and percentage error in data transfer were estimated. RESULTS: Data for all 5,537 antenatal registrants and 3, 466 deliveries recorded into the primary source for the first quarter of 2012 were assessed. Completeness was best for age data, followed by data on parity and hemoglobin at registration. Mean completeness of the facility level aggregate data for the data sampled, was 94.3% (95% CI = 90.6% - 98.0%) and 100.0% respectively for the aggregate form and DHIMS-II database. Mean error in data transfer was 1.0% (95% CI = 0.8% - 1.2%). Percentage error comparing aggregate form data and DHIMS-II data respectively to the primary source data ranged from 0.0% to 4.9% respectively, while percentage error comparing the DHIMS-II data to aggregate form data, was generally very low or 0.0%. CONCLUSION: Routine maternal health services data in the Greater Accra region, available at the district level through the DHIMS-II system is complete when compared to facility level primary source data and reliable for use.


Assuntos
Registros Eletrônicos de Saúde/normas , Serviços de Informação/organização & administração , Serviços de Saúde Materna/organização & administração , Estudos Transversais , Feminino , Gana , Humanos
9.
Org Biomol Chem ; 13(9): 2582-7, 2015 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-25573517

RESUMO

A rotaxane host system containing a novel halogen bonding (XB) 5-iodo-1,2,3-triazole functionalised pyridinium motif, within its axle component, has been prepared via a ring closing metathesis reaction, using chloride as a template. Proton NMR titration experiments, in competitive 1 : 1 CDCl3-CD3OD solvent media, showed the XB rotaxane selectively bound halides over larger, more basic oxoanions. An all hydrogen bonding proto-triazole containing rotaxane analogue was also prepared, which in stark contrast demonstrated a reversal in the anion selectivity trend, with a preference for dihydrogen phosphate over the halides which is unprecedented for an interlocked host system.

10.
PLoS One ; 9(8): e104053, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25144222

RESUMO

OBJECTIVES: The District Health Information Management System-2 (DHIMS-2) is the database for storing health service data in Ghana, and similar to other low and middle income countries, paper-based data collection is being used by the Ghana Health Service. As the DHIMS-2 database has not been validated before this study aimed to evaluate its validity. METHODS: Seven out of ten districts in the Greater Accra Region were randomly sampled; the district hospital and a polyclinic in each district were recruited for validation. Seven pre-specified neonatal health indicators were considered for validation: antenatal registrants, deliveries, total births, live birth, stillbirth, low birthweight, and neonatal death. Data were extracted on these health indicators from the primary data (hospital paper-registers) recorded from January to March 2012. We examined all the data captured during this period as these data have been uploaded to the DHIMS-2 database. The differences between the values of the health indicators obtained from the primary data and that of the facility and DHIMS-2 database were used to assess the accuracy of the database while its completeness was estimated by the percentage of missing data in the primary data. RESULTS: About 41,000 data were assessed and in almost all the districts, the error rates of the DHIMS-2 data were less than 2.1% while the percentages of missing data were below 2%. At the regional level, almost all the health indicators had an error rate below 1% while the overall error rate of the DHIMS-2 database was 0.68% (95% C I = 0.61-0.75) and the percentage of missing data was 3.1% (95% C I = 2.96-3.24). CONCLUSION: This study demonstrated that the percentage of missing data in the DHIMS-2 database was negligible while its accuracy was close to the acceptable range for high quality data.


Assuntos
Cuidado do Lactente/estatística & dados numéricos , Projetos de Pesquisa/normas , Feminino , Gana , Humanos , Recém-Nascido , Gravidez , Cuidado Pré-Natal
11.
Sleep Breath ; 17(3): 1071-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23354509

RESUMO

OBJECTIVE: The study compares polysomnography (PSG) and cardiopulmonary coupling (CPC) sleep quality variables in patients with (1) obstructive sleep apnea (OSA) and (2) successful and unsuccessful continuous positive airway pressure (CPAP) response. PATIENTS/METHODS: PSGs from 50 subjects (32 F/18 M; mean age 48.4 ± 12.29 years; BMI 34.28 ± 9.33) were evaluated. OSA patients were grouped by no (n = 16), mild (n = 13), and moderate to severe (n = 20) OSA (apnea-hypopnea index (AHI) ≤ 5, >5-15, >15 events/h, respectively). Outcome sleep quality variables were sleep stages in non-rapid eye movement, rapid eye movement sleep, and high (HFC), low (LFC), very low-frequency coupling (VLFC), and elevated LFC broad band (e-LFCBB). An AHI ≤ 5 events/h and HFC ≥ 50 % indicated a successful CPAP response. CPC analysis extracts heart rate variability and QRS amplitude change that corresponds to respiration. CPC-generated spectrograms represent sleep dynamics from calculated coherence product and cross-power of both time series datasets. RESULTS: T tests differentiated no and moderate to severe OSA groups by REM % (p = 0.003), HFC (p = 0.007), VLFC (p = 0.007), and LFC/HFC ratio (p = 0.038) variables. The successful CPAP therapy group (n = 16) had more HFC (p = 0.003), less LFC (p = 0.003), and e-LFCBB (p = 0.029) compared to the unsuccessful CPAP therapy group (n = 8). PSG sleep quality measures, except the higher arousal index (p = 0.038) in the unsuccessful CPAP group, did not differ between the successful and unsuccessful CPAP groups. HFC ≥ 50 % showed high sensitivity (77.8 %) and specificity (88.9 %) in identifying successful CPAP therapy. CONCLUSIONS: PSG and CPC measures differentiated no from moderate to severe OSA groups and HFC ≥ 50 % discriminated successful from unsuccessful CPAP therapy. The HFC ≥ 50 % cutoff showed clinical value in identifying sleep quality disturbance among CPAP users.


Assuntos
Eletrocardiografia/métodos , Polissonografia/métodos , Processamento de Sinais Assistido por Computador , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono/fisiologia , Sono REM/fisiologia , Adulto , Algoritmos , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Apneia Obstrutiva do Sono/classificação
12.
Sleep Med ; 10(7): 763-5, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19138881

RESUMO

OBJECTIVE: To describe celiac disease (CD) as a possible cause for low serum ferritin in patients with restless legs syndrome (RLS). BACKGROUND: Low iron stores have been found to be a risk factor for RLS with serum ferritin levels less than 45-50 ng/mL associated with increased severity of RLS. It has become routine clinical practice to test serum ferritin in the initial assessment of RLS. CD is a common genetic disorder that can cause iron deficiency. METHODS: Consecutive case series of four patients with RLS and serum ferritin below 25 ng/mL, who had positive screening tests for celiac disease. RESULTS: We report four patients who had serum ferritin < 12 ng/mL and positive screening tests for CD. All had CD confirmed by duodenal biopsy and response to a gluten-free diet. RLS symptoms improved in all four, with two able to discontinue RLS medication and two responding without medication. CONCLUSIONS: In patients with RLS and low serum ferritin who do not have an obvious cause for iron deficiency, we suggest looking for CD by simple, inexpensive serologic testing. Diagnosis and treatment of CD is likely to improve the outcome for RLS, as well as identify individuals who are at risk for the significant long-term complications of CD.


Assuntos
Doença Celíaca/sangue , Doença Celíaca/complicações , Ferritinas/sangue , Síndrome das Pernas Inquietas/complicações , Biópsia , Dieta Livre de Glúten , Duodeno/patologia , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Síndrome das Pernas Inquietas/diagnóstico , Índice de Gravidade de Doença
13.
Sleep Med ; 8(3): 271-6, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17369089

RESUMO

OBJECTIVE: Sleep-related material in medical textbooks may be the only method by which physicians educate themselves about sleep. In the last decade significant progress in sleep research has been made, but how textbooks in relevant fields reflect it has not been examined. Our purpose was to review and compare (2005 with 1998) sleep content in representative medical textbooks. METHODS: Sleep content of the latest edition of textbooks in four specialties was evaluated. Present sleep content in seven textbooks was compared with that found in 1998. Numbers of pages devoted to sleep were counted and reported for the subjects covered and for the specialty of the textbook. RESULTS: Thirty-one textbooks were examined for current content and seven textbooks for content comparison. Sleep coverage in medical textbooks uniformly received less than 2% of the text volume. Focus of topics covered varied with specialty. Compared with 1998, the proportion of pages devoted to sleep remained the same or decreased. Coverage of new topics remained minimal. CONCLUSIONS: Major medical textbooks present small amounts of sleep content and few provide a comprehensive overview of sleep medicine. In comparison to textbook editions from the 1990s, current editions still devote little attention to sleep, and the diversity of topics has not improved.


Assuntos
Educação de Pós-Graduação em Medicina , Educação Médica , Transtornos do Sono-Vigília , Especialização , Livros de Texto como Assunto , Currículo , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...