Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(5)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38592319

RESUMO

The purpose of this study is to compare outcomes in patients undergoing buried and non-buried free flaps for breast reconstruction, in addition to evaluating the safety and reliability of venous flow couplers. A retrospective review was performed of all patients undergoing free flap breast reconstruction between 2013 and 2023. The primary outcomes were free flap failure, complications and the number of procedures required to complete the reconstructive journey. A total of 322 flaps were performed in 254 consecutive patients, with 47.5% (n = 153) being buried and 52.0% (n = 169) being non-buried reconstructions. The most common flap of choice being deep inferior epigastric artery perforator flaps (81.9%) followed by profunda artery perforator flaps (14.3%). There was no significant difference between the two groups in complications, including flap failure (buried 2.0% vs. non-buried 1.8% p = 0.902). There was a significant reduction in the number of procedures required to complete the reconstructive journey, with 52.2% (n = 59) of patients undergoing single-stage breast reconstruction in the buried group compared with only 25.5% (n = 36) in the non-buried group (p < 0.001). Two (0.6%) patients experienced a false negative in which the signal of the flow coupler was lost but the flap was perfused during re-exploration. No flap losses occurred without being identified in advance by a loss of audible venous flow signal. Buried free flap breast reconstruction is safe and requires fewer operations to complete patients' reconstructive journey. Flow couplers are a safe and effective method of monitoring buried free flaps in breast reconstruction.

2.
Cureus ; 15(11): e48238, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37929272

RESUMO

Metal-on-metal (MoM) total hip arthroplasty has been widely used since the end of the 20th century, although rates have now decreased due to concerns regarding adverse reactions and failure rates. The MoM implant has been replaced with other materials, such as ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP). This literature review looks at the past and present use of MoM prostheses to assess whether the turn away from MoM use is justified. Online literature searches were performed on PubMed, Ovid Medical Literature Analysis and Retrieval System Online (MEDLINE), and Web of Science online databases using the search terms "MoM and (ARMD and ALVAL)" (ARMD: adverse reaction to metal debris; ALVAL: aseptic lymphocyte-dominant vasculitis-associated lesion). A total of 64 relevant titles were included in the review. Although risk factors for adverse reactions and the causes of ARMD are generally agreed upon, more work is required to further understand the specific thresholds of blood metal ion levels that can be used to consistently identify ARMD and excessive metal wear-debris in patients who have not had their MoM implants revised. Metal-on-metal devices are not an acceptable option for total hip arthroplasties (THAs) in their current formulation due to the high rate and risk of ARMD. Some MoM hip resurfacing operations are appropriate for very carefully selected patients who are fully aware of the risks posed by the implant. It is recommended that device-specific thresholds for metal ion levels be developed to identify patients at risk of ARMD locally and systemically while using auxiliary tools to assist diagnosis, such as metal artefact reduction sequences (MARS)-MRI and hip scoring tools. Further work should investigate device-specific blood metal ion levels, the systemic effects of raised metal ion concentrations secondary to MoM arthroprosthetic wear, and the potential risks of ARMD caused by wear from tapered stems (including the implications this has for patients with CoC and MoP prostheses).

3.
J Surg Case Rep ; 2021(1): rjaa572, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33505660

RESUMO

A case of bilateral traumatic distal femoral Salter-Harris Type I fracture presented to our emergency department. History was of a 9-year-old male playing at a building site when a concrete block fell from height on to his knees, which were extended in a sitting position. Management was with analgesia and transfer to theatre followed by closed reduction and internal fixation-position was assessed under mobile X-ray. The patient made a full clinical recovery within 18 weeks and was followed-up over 5 years. There was no clinical effect on final adult length of femur and no deficit in range of movement. The foot-drop observed at presentation resolved over a period of 12 weeks. This case highlights the importance of performing a thorough neurovascular examination of the patient at presentation, followed by a careful closed reduction and internal fixation under anaesthesia, being careful not to damage the distal femoral growth plates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...